Chemiluminescence Imaging System LCIS-A20

Chemiluminescence Imaging System LCIS-A20

Chemiluminescence Imaging System LCIS-A20 is a new generation, an integrated device for used for imaging Chemiluminescence Gel with exceptionally high quantum efficiency CCD Camera for greater sensitivity and dynamic range. It offers a 12.49 × 9.99 mm CCD Sensor Size, with 6.05 MP resolution, F0.8 motorized lens, and -30˚C cooling temperature. The 16-bit (65536 Grey Scales) CCD camera reduces the background noise during a long exposure time. The device can detect far weaker signals, offers higher sensitivity and a wider linear range. The device configuration offered as documentation of RNA, DNA, Protein, and Chemiluminescence imaging system.

View Catalog
CCD Sensor Size 12.49 × 9.99 mm
Resolution 6.05 Megapixels, 2750 × 2200
Pixel Density 16bit (65536 Grey Scales)
Pixel Size 4.54 × 4.54 µm
Lens F0.8 motorized lens
Light Source LED Epi-white light × 2
UV-Transilluminator (302 nm)
White-LED Transilluminator
Display NA
Quantum efficiency ≥ 75 %
Readout noise < 5.5e- RMS
Dark current 0.0003 e/p/s
Dynamic range 4 order of magnitude
Standard Filter 590 nm filter
Filter Wheel 8 Sockets Filter Wheel
Max Image Area 260 × 210 mm
Cooling Temperature -30˚C
Software Image acquisition and analysis software
Dimension 560 × 480 × 780 mm + 380 × 350 × 490 mm
Gross Weight 39 kg
  • ≥ 75 % High Quantum efficiency of the CCD camera
  • CCD Sensor Size offered is 12.49 × 9.99 mm, with a 6.05 MP resolution
  • Offers convenient image navigation and browsing
  • Optional attachment of different fluorescent light sources and filters
  • Automatic pixel binning technology
  • Marker image capture and composition with objective bands
  • Small footprint - takes up minimal bench space
  • Configured for maximum sensitivity to ensure even the faintest band on a blot can be captured
  • Optional full configuration system Analysis System (DNA, RNA, Protein, Chemiluminescence, Fluorescence)
Chemiluminescence Imaging System used in genetic engineering, biotechnology, molecular biology for obtaining high-quality images of DNA/RNA bands, also for protein detection, ELISA plate reading, and Chemiluminescence analysis.
Optional System Configuration of RNA, DNA, Protein, Chemiluminescence, Fluorecence System
High precise automatic exposure and automatic recognition of the gel bands
Offers one touch image acquisition and save
Marker image capture and composition with objective bands
Automatic access of capture parameters and calculation of the density and the peak value of each band
Convenient image navigation and browsing
It adopts image rotation, cropping and counter color processing
Advanced pixel binning technology
Optional save of analysis results as excels files
Calculation of the optical density for the quantitative analysis
It offers optimization of the visual effects by wiping background mode
Related products