- Microprocessor-based PID temperature controller, LCD screen
- R134a refrigerant, imported compressor
- Separate temperature-limiting alarm system for safe usage
- Options are available to connect printer and computer for data recording
Cooling incubators LCOI-B14 with microprocessor-based temperature controller to maintain uniform temperature for safe usage. Designed with polished stainless-steel chamber and semicircular arcs at corners for easy cleaning, and the adjustable shelves in the chamber for easy spacing as per the need. It is available in different temperature ranges.
Shelves | 3(pcs) |
Display Resolution | 0.1 ℃ |
Temperature Range | 0 ~ 60 ℃ |
Temperature Stability | High: ± 0.5 ℃ Low: ± 1 ℃ |
Ambient Temperature | 5 ℃ ~ 30 ℃ |
Timing Range | 1 ~ 5999 min |
Interior Dimension(W × D × H) | 1050 × 590 × 1650 mm |
Exterior Dimension(W × D × H) | 1410 × 890 × 1950 mm |
Power Consumption | 4100 W |
Power | 380 V, 50 Hz |
It incorporates advantage of both closed and shaking incubation required for no. of processes which includes tissue culture, enzyme reaction, fermentation etc. It is highly efficient with user-friendly operation.
Display | LCD |
Circulation Mode | Forced convection |
Shaking Mode | Rotatory Shaking |
Display | LCD |
Circulation Mode | Forced convection |
Shaking Mode | Rotatory Shaking |
Shaking Speed Range | 40 to 300 rpm |
Platform Size | 280 × 220 mm |
Display Resolution | 0.1 ℃ |
Shaking Speed Range | 40 to 300 rpm |
Platform Size | 350 × 350 mm |
Display Resolution | 0.1 ℃ |
This wide range of cooling incubators is available in different temperature ranges and it is suitable to serve for preservation of culture medium, serum, medicine as well as micro-organism training and environmental testing, etc.
Equipped with inner glass door for easy operation, our heating incubators deliver a higher level of performance for storage and cultivation purpose. This range is available in different chamber volume.
Temperature range | RT. 5°C ~ 160°C |
Temperature control range | |
Temperature setting range |
Temperature range | RT. 5°C ~ 130°C |
Temperature control range | |
Temperature setting range |
Temperature range | RT. 5°C ~ 100°C |
Temperature control range | |
Temperature setting range |
Temperature range | RT. 5°C ~ 100°C |
Temperature control range | |
Temperature setting range | 0 °C - 100 °C |
Capacity | 250 L |
Illumination type | 2 side illumination |
Light source | Fluorescent lamp |
Capacity | 350 L |
Illumination type | 2 side illumination |
Light source | Fluorescent lamp |
Capacity | 450 L |
Illumination type | 2 side illumination |
Light source | Fluorescent lamp |
Capacity | 250 L |
Illumination type | 3-side illumination |
Illumination source | Fluorescent lamp |
Capacity | 350 L |
Illumination type | 3-side illumination |
Illumination source | Fluorescent lamp |
Capacity | 450 L |
Illumination type | 3-side illumination |
Illumination source | Fluorescent lamp |
Control System | Microcomputer control system |
Display | LCD display with button-press keypad |
Time for creating anaerobic state in sample chamber | < 5 minutes |
Control System | Microprocessor control system + Siemens PLC |
Display | LCD display with touch screen control panel |
Time for creating anaerobic state in sample chamber | < 5 minutes |
Time for creating anaerobic state in sample chamber | < 5 min |
Time for creating anaerobic state in operation chamber | < 1 hour (Oxygen concentration ≤ 1 %) |
Anaerobic environment maintenance time | > 12 h (when no supply of mixed gas) |
Air cycle Mode | Gravity air convection |
Function | |
Body structure |
Air cycle Mode | Natural air convection |
Function | |
Body structure |
Air cycle Mode | Natural air convection |
Function | |
Body structure |