Light source |
Semiconductor laser |
Measuring range |
0.8 µm to 600 µm (Depends on the sensor) |
Sensitivity |
0.8 µm (1S04402) or 3 µm (c) |
Measuring channels |
16 channels, particle size can be set arbitrarily |
Sampling volume |
0.2 to 100 ml, interval 0.1 ml |
Sampling volume precision |
Be superior to ± 0.5 % |
Sampling speed |
5 to 80 ml/min |
Cleaning speed |
5 to 80 ml/min |
Resolution |
Be superior to 10 % 1S011171 |
Coincidence error limit |
12000 to 40000 particles/ml (Depends on the sensor) |
Repeatability |
RSD < 2 % |
Count accuracy |
± 10 % |
Air pressure chamber maximum vacuum |
- 0.08 mPa |
Air pressure chamber maximum pressure |
1 mPa |
Test sample viscosity |
≤ 650 cSt |
Test sample temperature |
0°C to 80°C |
Work temperature |
0°C to 60°C |
Storage temperature |
-30°C to 80°C |
Power supply |
100 to 245 V, 49 to 62 Hz |
Overall dimensions |
Mainframe 430 × 320 × 590 mm Air pressure bump 330 × 266 × 255mm |
Instrument net weight |
Mainframe 30 kg Air pressure bump 10 kg |
-
Based on Light Blocking Method to achieve rapid detection speed, accuracy and good repeatability
High precision sensors are used to get a higher resolution
Syringe sampling system: To achieve constant sampling speed and to control sample volume
Pressurized sample delivery to degas the sample and increase the accuracy
Color LCD display, touch screen, graphics menu to make the operations simple
Several standards to rate the particle pollution are stored and also new standards can also be added
Granularity and size of 9900 particles can be easily analysed through different channels
Four calibration curves: latex ball calibration curve, ACFTD calibration curve, ISDMTD calibration curve, GOST calibration curve
Curves can be switched to minimise conversion error and can be stored
Data storage function to retrieve the data easily
Test reports can be printed through built-in printer
Advanced software and RS232 interface to connect external computer
Magnetic stirring to distribute the particles evenly
Gas filtration and purification system to eliminate contaminants from air pressure pump
It finds application in detection of solid pollutants in lubricating oil, insulating oil, hydraulic oil, aviation kerosene etc. It can trace the insoluble particles in polymer solution and organic liquid. Therefore it has wide applications in petroleum industry, chemical industry, automobile manufacturing, aerospace and many other fields.
{"Light source":"Semiconductor laser","Measuring range":"0.8 \u00b5m to 600 \u00b5m (Depends on the sensor)","Sensitivity":"0.8 \u00b5m (1S04402) or 3 \u00b5m (c)","Measuring channels":"16 channels, particle size can be set arbitrarily","Sampling volume":"0.2 to 100 ml, interval 0.1 ml","Sampling volume precision":"Be superior to \u00b1 0.5 %","Sampling speed":"5 to 80 ml\/min","Cleaning speed":"5 to 80 ml\/min","Resolution":"Be superior to 10 % 1S011171","Coincidence error limit":"12000 to 40000 particles\/ml (Depends on the sensor)","Repeatability":"RSD < 2 %","Count accuracy":"\u00b1 10 %","Air pressure chamber maximum vacuum":"- 0.08 mPa","Air pressure chamber maximum pressure":"1 mPa","Test sample viscosity":"\u2264 650 cSt","Test sample temperature":"0\u00b0C to 80\u00b0C","Work temperature":"0\u00b0C to 60\u00b0C","Storage temperature":"-30\u00b0C to 80\u00b0C","Power supply":"100 to 245 V, 49 to 62 Hz","Overall dimensions":"Mainframe 430 \u00d7 320 \u00d7 590 mm
Air pressure bump 330 \u00d7 266 \u00d7 255mm","Instrument net weight":"Mainframe 30 kg
Air pressure bump 10 kg"}
Based on Light Blocking Method to achieve rapid detection speed, accuracy and good repeatability
High precision sensors are used to get a higher resolution
Syringe sampling system: To achieve constant sampling speed and to control sample volume
Pressurized sample delivery to degas the sample and increase the accuracy
Color LCD display, touch screen, graphics menu to make the operations simple
Several standards to rate the particle pollution are stored and also new standards can also be added
Granularity and size of 9900 particles can be easily analysed through different channels
Four calibration curves: latex ball calibration curve, ACFTD calibration curve, ISDMTD calibration curve, GOST calibration curve
Curves can be switched to minimise conversion error and can be stored
Data storage function to retrieve the data easily
Test reports can be printed through built-in printer
Advanced software and RS232 interface to connect external computer
Magnetic stirring to distribute the particles evenly
Gas filtration and purification system to eliminate contaminants from air pressure pump
It finds application in detection of solid pollutants in lubricating oil, insulating oil, hydraulic oil, aviation kerosene etc. It can trace the insoluble particles in polymer solution and organic liquid. Therefore it has wide applications in petroleum industry, chemical industry, automobile manufacturing, aerospace and many other fields.