PMCC Flash Point Tester LCFP-A10

LCFP-A10 is compact, stand-alone closed cup flash point tester which determines the low temperature operability in diesel fuel, biodiesel, blends and gas oils. It is designed as per “Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods)” ASTM D93.

Buy Now View Catalog
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Ignition Mode
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Standard oil cup-Inner diameter 50.7 ~ 50.8 mm
Standard oil cup- Depth 55.7 ~ 56.0 mm
Standard oil cup- Depth of Marked line on the oil cup 33.9 ~ 34.3 mm
Standard oil cup-Oil sample cubage About 70 ml
Stirring speed 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B
Stirring blade 8 × 40 mm
Sample temperature rising rate 1 ~ 12 °C per minute
Measurement Range
Flash Point
Resolution
Repeatability
Reproducibility
Accuracy
Precision
Gas Flame
Heating power 0 ~ 600 W
Dimension 420 × 350 × 350 mm
Total Power Consumption 600 W
Power supply AC 220 V ± 10 %, 50 Hz
Net Weight
  • Ignition source : Coal gas Rod type Mercury Thermometer Variable Temperature Range 45TYZ Stirring Motor

It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 °C

{"Ambient temperature":"\u2264 35 \u00b0C","Relative humidity":"\u2264 85 %","Ignition Mode":"","Temperature range":"5 \u00b0C ~ 110 \u00b0C, Each scale division is 0.5 \u00b0C; 20 \u00b0C ~ 150 \u00b0C, Each scale division is 1.0 \u00b0C; 90 \u00b0C ~ 370 \u00b0C, Each scale division is 2 \u00b0C","Aperture of ignition device":"0.8 mm","Standard oil cup-Inner diameter":"50.7 ~ 50.8 mm","Standard oil cup- Depth":"55.7 ~ 56.0 mm","Standard oil cup- Depth of Marked line on the oil cup":"33.9 ~ 34.3 mm","Standard oil cup-Oil sample cubage":"About 70 ml","Stirring speed":"90 ~ 120 rpm for procedure A; 250 \u00b1 10 rpm for procedure B","Stirring blade":"8 \u00d7 40 mm","Sample temperature rising rate":"1 ~ 12 \u00b0C per minute","Measurement Range":"","Flash Point":"","Resolution":"","Repeatability":"","Reproducibility":"","Accuracy":"","Precision":"","Gas Flame":"","Heating power":"0 ~ 600 W","Dimension":"420 \u00d7 350 \u00d7 350 mm","Total Power Consumption":"600 W","Power supply":"AC 220 V \u00b1 10 %, 50 Hz","Net Weight":""}
Ignition source : Coal gas Rod type Mercury Thermometer Variable Temperature Range 45TYZ Stirring Motor
It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 °C


Related Products of Closed Cup Flash Point Tester

Automatic PMCC Flash Point Tester LCFP-A11

Automatic PMCC Flash Point Tester LCFP-A11

Ambient temperature : 10 °C ~ 40 °C

Relative humidity : ≤ 80 %

Measurement Range : Ambient Temperature ~ 250 °C

Automatic PMCC Flash Point Tester LCFP-A13

Automatic PMCC Flash Point Tester LCFP-A13

Ambient temperature : 10 °C ~ 40 ℃

Relative humidity : ≤ 80 %

Ignition Mode : electron igniter / gas flame

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10

Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Acid Number and Acidity Tester LAAT-A11
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Ash Content Tester

Ash Content Tester LACT-A10
Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W

Aniline Point Tester LAPT-A11

Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A11
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Talk to us?