Cleveland Open Cup Flash Point Tester LOFP-A11

Labtron LOFP-A11 is designed with quartz tube heater which is highly efficient and cost effective and used to trace many products. It is designed and made as per ISO 2592, ASTM 92 “Test Methods for Flash and Fire Point of Petroleum Products (Cleveland Open Cup Methods)”.

Buy Now View Catalog
Thermometer 6 ℃ ~ 400 ℃
Scale Division 2 °C
Spout Aperture 0.6 ~ 0.8 mm
Ambient Temperature -10 ℃ ~ 50 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale
Temperature Measurement- Repeatability
Temperature Measurement- Reproducibility
Temperature Measurement- Resolution
Test accuracy
Reappearance
Graduation
Outer Crucible-Material
Outer Crucible-Diameter Of Upper Opening
Outer Crucible-Height
Outer Crucible-Diameter Of Bottom
Inner Crucible-Material
Inner Crucible-Diameter Of Upper Opening
Inner Crucible-Height
Inner Crucible-Diameter Of Bottom
Inner Crucible-Scale Line
Precision
Gas Tube
Flame
Heater
Heating Power
Dimensions 480 x 400 x 300 mm
Power Consumption 0 ~ 600 W
Power Supply AC 220 V ± 10 %, 50 Hz
=#REF!
  • Explosion protective Power can be constantly adjusted Robotically scanning flame application gadget Coal gas as ignition source

It is suitable to determine flash point and fire point of petroleum products having a flash point higher than 79 °C, excepting fuel oils

{"Thermometer":"6 \u2103 ~ 400 \u2103","Scale Division":"2 \u00b0C","Spout Aperture":"0.6 ~ 0.8 mm","Ambient Temperature":"-10 \u2103 ~ 50 \u2103","Relative Humidity":"\u2264 85 %","Temperature Measurement- Full Scale":"","Temperature Measurement- Repeatability":"","Temperature Measurement- Reproducibility":"","Temperature Measurement- Resolution":"","Test accuracy":"","Reappearance":"","Graduation":"","Outer Crucible-Material":"","Outer Crucible-Diameter Of Upper Opening":"","Outer Crucible-Height":"","Outer Crucible-Diameter Of Bottom":"","Inner Crucible-Material":"","Inner Crucible-Diameter Of Upper Opening":"","Inner Crucible-Height":"","Inner Crucible-Diameter Of Bottom":"","Inner Crucible-Scale Line":"","Precision":"","Gas Tube":"","Flame":"","Heater":"","Heating Power":"","Dimensions":"480 x 400 x 300 mm","Power Consumption":"0 ~ 600 W","Power Supply":"AC 220 V \u00b1 10 %, 50 Hz","=#REF!":""}
Explosion protective Power can be constantly adjusted Robotically scanning flame application gadget Coal gas as ignition source
It is suitable to determine flash point and fire point of petroleum products having a flash point higher than 79 °C, excepting fuel oils


Related Products of Open Cup Flash Point Tester

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Ambient Temperature : 10 ℃ ~ 40 °C

Relative Humidity : ≤ 80 %

Temperature Measurement- Full Scale : Ambient temperature to 300 °C

Automatic COC Flash & Fire Point Tester LOFP-B10

Automatic COC Flash & Fire Point Tester LOFP-B10

Ambient Temperature : 10 ℃ ~ 40 ℃

Relative Humidity : ≤ 85 %

Temperature Measurement- Full Scale : Ambient temperature to ~ 400 ℃

Open Cup Flash Point Tester LOFP-A10
Open Cup Flash Point Tester LOFP-A10

Thermometer : 0 ℃ ~ 360 °C

Scale Division : 1 °C

Ambient Temperature : ≤ 35 °C

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W

Aniline Point Tester LAPT-A11

Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml

Ash Content Tester

Ash Content Tester LACT-A10
Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Talk to us?