Automatic COC Flash & Fire Point Tester LOFP-B10

Our LOFP-B10 is deliberately furnished to determine both flash point and fire point. It has a wide range of applications with a great market value. It is designed as per the standard ASTM D92, ISO2592, IP36 (Standard Test Method for Flash Point of Petroleum Products-Cleveland Open Cup Method).

Buy Now View Catalog
Thermometer
Scale Division
Spout Aperture
Ambient Temperature 10 ℃ ~ 40 ℃
Relative Humidity ≤ 85 %
Temperature Measurement- Full Scale Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability ≤ 4 ℃
Temperature Measurement- Reproducibility
Temperature Measurement- Resolution
Test accuracy 0.005
Reappearance ≤ 8 times
Graduation 0.1 ℃
Outer Crucible-Material
Outer Crucible-Diameter Of Upper Opening
Outer Crucible-Height
Outer Crucible-Diameter Of Bottom
Inner Crucible-Material
Inner Crucible-Diameter Of Upper Opening
Inner Crucible-Height
Inner Crucible-Diameter Of Bottom
Inner Crucible-Scale Line
Precision
Gas Tube
Flame
Heater
Heating Power
Dimensions 620 x 500 x 440 mm
Power Consumption 400 W
Power Supply AC 220 V ± 10 %, 50 Hz
=#REF!
  • Highly precise LCD display Desktop structure and innovative design Fully-automatic Single chip microcomputer technology It have options of presetting the parameters of expected sample mark number, atmospheric pressure and test date

It can be widely used in railway, aviation, electric power, petroleum industry and colleges, scientific research institutes, measurement departments to do determination of flash point and fire point for petroleum products except oil fuel and samples whose open cup flash point is below 79 ℃

{"Thermometer":"","Scale Division":"","Spout Aperture":"","Ambient Temperature":"10 \u2103 ~ 40 \u2103","Relative Humidity":"\u2264 85 %","Temperature Measurement- Full Scale":"Ambient temperature to ~ 400 \u2103","Temperature Measurement- Repeatability":"\u2264 4 \u2103","Temperature Measurement- Reproducibility":"","Temperature Measurement- Resolution":"","Test accuracy":"0.005","Reappearance":"\u2264 8 times","Graduation":"0.1 \u2103","Outer Crucible-Material":"","Outer Crucible-Diameter Of Upper Opening":"","Outer Crucible-Height":"","Outer Crucible-Diameter Of Bottom":"","Inner Crucible-Material":"","Inner Crucible-Diameter Of Upper Opening":"","Inner Crucible-Height":"","Inner Crucible-Diameter Of Bottom":"","Inner Crucible-Scale Line":"","Precision":"","Gas Tube":"","Flame":"","Heater":"","Heating Power":"","Dimensions":"620 x 500 x 440 mm","Power Consumption":"400 W","Power Supply":"AC 220 V \u00b1 10 %, 50 Hz","=#REF!":""}
Highly precise LCD display Desktop structure and innovative design Fully-automatic Single chip microcomputer technology It have options of presetting the parameters of expected sample mark number, atmospheric pressure and test date
It can be widely used in railway, aviation, electric power, petroleum industry and colleges, scientific research institutes, measurement departments to do determination of flash point and fire point for petroleum products except oil fuel and samples whose open cup flash point is below 79 ℃


Related Products of Open Cup Flash Point Tester

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Automatic Cleveland Open Cup Flash Point Tester LOFP-A12

Ambient Temperature : 10 ℃ ~ 40 °C

Relative Humidity : ≤ 80 %

Temperature Measurement- Full Scale : Ambient temperature to 300 °C

Open Cup Flash Point Tester LOFP-A10

Open Cup Flash Point Tester LOFP-A10

Thermometer : 0 ℃ ~ 360 °C

Scale Division : 1 °C

Ambient Temperature : ≤ 35 °C

Cleveland Open Cup Flash Point Tester LOFP-A11
Cleveland Open Cup Flash Point Tester LOFP-A11

Thermometer : 6 ℃ ~ 400 ℃

Scale Division : 2 °C

Spout Aperture : 0.6 ~ 0.8 mm

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10

Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml
Water Soluble Acid and Alkali Tester LAAT-A10
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml

Ash Content Tester

Ash Content Tester LACT-A10
Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Automatic Bomb Calorimeter LABC-A10

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Aniline Test Equipment

Aniline Point Tester LAPT-A10
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Aniline Point Tester LAPT-A11
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Talk to us?