Transformer Oil Oxidation Stability Tester LOST-D11

Labtron LOST-D11 features metal bath for uniform heating, keeping the temperature constant. Equipped with pressure reducer ensuring constant output pressure of the gas cylinder when the pressure in the gas cylinder decreases. Furnished with 6 flow meters to adjust and indicate the flow rate in 6 oxidation tubes.

Buy Now View Catalog
Samples 6
Temperature
Oil bath cubage
Angle between bomb and water surface
Speed of rotary assembly
Pressure sensor
Oil bath Temperature controlling range
Temperature controlling mode Automatic digital temperature
Temperature controlling range Room temperature ~ 160 °C
Temperature controlling accuracy ± 0.2 °C
Flow meter
Size
Power of heater
Power supply 220 V, 50 Hz
Power consumption ≤ 1100 W
Weight
Dimension
  • Digital temperature controller for automatic mode
    Desktop type and compact
    Pressure reducer (ensuring constant output pressure)
    Digital timer (presetting and recording test time)

It can be widely used in petroleum, chemical industries, research and development laboratories.

{"Samples":"6","Temperature":"","Oil bath cubage":"","Angle between bomb and water surface":"","Speed of rotary assembly":"","Pressure sensor":"","Oil bath Temperature controlling range":"","Temperature controlling mode":"Automatic digital temperature","Temperature controlling range":"Room temperature ~ 160 \u00b0C","Temperature controlling accuracy":"\u00b1 0.2 \u00b0C","Flow meter":"","Size":"","Power of heater":"","Power supply":"220 V, 50 Hz","Power consumption":"\u2264 1100 W","Weight":"","Dimension":""}
Digital temperature controller for automatic mode
Desktop type and compact
Pressure reducer (ensuring constant output pressure)
Digital timer (presetting and recording test time)
It can be widely used in petroleum, chemical industries, research and development laboratories.


Related Products of Oxidation Stability Tester

Gasoline Oxidation Stability Tester LOST-D13

Gasoline Oxidation Stability Tester LOST-D13

Type : Compact; Desktop

Design : Integrated

Bath : Metal bath (without water usage)

Oxidation Stability Tester (Lubricating Grease) LOST-D20

Oxidation Stability Tester (Lubricating Grease) LOST-D20

Temperature Range : Ambient to 150℃

Temperature Precision : ± 0.1°C

Test Unit : 2 units

Distillate Fuel Oil Oxidation Stability Tester LOST-D12
Distillate Fuel Oil Oxidation Stability Tester LOST-D12

Samples : 8

Temperature : 100 ℃

Temperature controlling accuracy : 0.1 ℃

Automatic Lubricating Oils Oxidation Stability Tester LOST-D10
Automatic Lubricating Oils Oxidation Stability Tester LOST-D10

Samples : 2

Oil bath cubage : 30 L

Angle between bomb and water surface : 30 °

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml

Ash Content Tester

Ash Content Tester LACT-A10
Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Aniline Test Equipment

Aniline Point Tester LAPT-A11
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Aniline Point Tester LAPT-A10

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10

Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg