Melting Point Apparatus LDMP-B11

Melting Point Apparatus LDMP-B11

Melting Point Apparatus LDMP-B11 offers desktop design, Semi- automatic detection method, with cooling function. Equipped with Peltier precise temperature function, In line with international standards such as CE & ISO for determination of the melting point of oils and fats. With addition of either high-definition camera or high definition video and camera technology, to delivers accurate, stable results, and user can clearly see the whole process of sample melting, automatic detection to eliminate the subjective error to determine the melting point.

View Catalog
Temperature control range 6 to 100℃
Detection method Semi-automatic
Capacity per batch 2 pcs/batch
Temperature resolution 0.1℃
Temperature gradients (0.1 to 10.0)℃/Min
Temperature accuracy ±0.3℃
Repeatability 0.1℃/Min , ±0.1℃
Camera & Video Camera & Video
Video playback Yes
Operator account 8
Result storage 400
SD card capacity 8G
Display TFT Touch screen
Interface USB RS232 SD card Enternet
Opening capillary size I.D>1.0 mm, O.D.1.4 mm Double opening
Power 110 to 220V 50, 60HZ 120W
Dimension 400 × 280× 330 mm
Weight 5 kg
  • TFT touch screen display
  • Semi- automatic detection method, with cooling function
  • Capacity per batch is 2 pcs
  • Designed with a key automatic detection function
  • Use of double opening capillary size I.D>1.0 mm,O.D.1.4 mm
  • In line with international standards such as CE & ISO
  • Adopted with Peltier precise temperature function technology
It finds application across finding meting point of oil and fat in food and drug industry, biochemistry, medicines, mining, water management industry.

Touch Screen Melting Point Apparatus

Touch Screen Melting Point Apparatus : Melting Point Apparatus LDMP-A12

Melting Point Apparatus LDMP-A12

Temperature RangeRT to 320°C
Cooling FunctionNO
Sample CellCapillary tube
Touch Screen Melting Point Apparatus : Melting Point Apparatus LDMP-A13

Melting Point Apparatus LDMP-A13

Temperature RangeRT to 400°C
Cooling FunctionBuilt-in Cooling Fan
Sample CellCapillary tube
Touch Screen Melting Point Apparatus : Melting Point Apparatus LDMP-A20
Melting Point Apparatus LDMP-A20
Temperature rangeRoom temperature to 350 ℃
Detection modeFully automatic (compatible with manual)
Processing capacity4 / batch
Touch Screen Melting Point Apparatus : Melting Point Apparatus LDMP-B10
Melting Point Apparatus LDMP-B10
Temperature control rangeRT to 100℃
Detection methodSemi-automatic
Capacity per batch2 pcs/batch