Conductivity measurement range |
0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm |
Conductivity calibration points |
1 to 3 points |
Conductivity accuracy |
±1 % F.S. |
Conductivity resolution |
0.001/ 0.01/ 0.1/ 1 |
Conductivity calibration solutions |
84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm |
TDS measurement range |
0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
TDS accuracy |
±1 % F.S. |
TDS factor |
0.1 to 1.0 |
Temperature measurement range |
0 to 100°C, 32 to 212°F |
Temperature accuracy |
1°C |
Temperature resolution |
0.1°C |
Temperature calibration points |
1 point |
Temperature calibration range |
Measured value ± 10°C |
Signal output |
4 to 200 mA |
Load |
Max. 500 Ω |
Low and high alarm limits |
0.02 uS/ cm to 20.0 mS/ cm, selectable |
Interface |
RS485 |
Connection terminals |
Detachable screw terminals |
Temperature compensation |
Automatic, 0 to 100°C , 32 to 212°F |
Cell constant |
K= 0.1, 1, 10 |
Environmental conditions |
Ambient temperature to ≤ 60°C, RH ≤ 80% |
Reference temperature |
25°C |
Display |
LCD |
Power |
DC 24 V |
Dimension (L*W*H) |
96 × 96 × 75 mm |
Weight |
350 g |
-
Equipped with industrial conductivity electrode
1 to 3 conductivity calibration points, 1 temperature calibration point
Selectable temperature units °C or °F for diff. applications
System menu allows setting of up to 9 parameters
Reset features to resumes all setting back to default
ATC mode for accurate readings over entire range
Low and high alarm limits set automatically activate an external device
Manual temperature calibration improves accuracy
Accessories no. |
Name |
Qty. |
1 |
Industrial Conductivity electrode |
1 |
2 |
Conductivity calibration solutions (bottle of 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm) |
1 each |
|
|
|
Accessories no. |
Name |
Qty. |
1 |
Industrial Conductivity electrode for measuring pure water |
1 |
2 |
Industrial Conductivity electrode for measuring general liquids |
1 |
3 |
Industrial Conductivity electrode for measuring high conductivity liquids |
1 |
4 |
Conductivity calibration solutions (bottle of 84 µS/ cm, 1413 µS/ cm, 12.88 mS/ cm,111.8 mS/ cm) |
1 each |
|
|
|
Used to measure conductivity and TDS values required for quality checking and research purpose across water treatment plants, filtration units, RO treatment plants, Agriculture industry, Aquaculture industry and others.
{"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/ cm, 20.00, 200.0 mS\/ cm","Conductivity calibration points":"1 to 3 points","Conductivity accuracy":"\u00b11 % F.S.","Conductivity resolution":"0.001\/ 0.01\/ 0.1\/ 1","Conductivity calibration solutions":"84 \u00b5S\/ cm, 1413 \u00b5S\/ cm, 12.88 mS\/ cm,111.8 mS\/ cm","TDS measurement range":"0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS accuracy":"\u00b11 % F.S.","TDS factor":"0.1 to 1.0","Temperature measurement range":"0 to 100\u00b0C, 32 to 212\u00b0F","Temperature accuracy":"1\u00b0C","Temperature resolution":"0.1\u00b0C","Temperature calibration points":"1 point","Temperature calibration range":"Measured value \u00b1 10\u00b0C","Signal output":"4 to 200 mA","Load":"Max. 500 \u03a9","Low and high alarm limits":"0.02 uS\/ cm to 20.0 mS\/ cm, selectable","Interface":"RS485","Connection terminals":"Detachable screw terminals","Temperature compensation":"Automatic, 0 to 100\u00b0C , 32 to 212\u00b0F","Cell constant":"K= 0.1, 1, 10","Environmental conditions":"Ambient temperature to \u2264 60\u00b0C, RH \u2264 80%","Reference temperature":"25\u00b0C","Display":"LCD","Power":"DC 24 V","Dimension (L*W*H)":"96 \u00d7 96 \u00d7 75 mm","Weight":"350 g"}
Equipped with industrial conductivity electrode
1 to 3 conductivity calibration points, 1 temperature calibration point
Selectable temperature units °C or °F for diff. applications
System menu allows setting of up to 9 parameters
Reset features to resumes all setting back to default
ATC mode for accurate readings over entire range
Low and high alarm limits set automatically activate an external device
Manual temperature calibration improves accuracy
Used to measure conductivity and TDS values required for quality checking and research purpose across water treatment plants, filtration units, RO treatment plants, Agriculture industry, Aquaculture industry and others.