Pocket ORP tester LPOT-A10

Pocket ORP tester LPOT-A10 is easy to use ORP meter equipped with a platinum sensor. It is suitable for measuring the oxidation reduction potential of liquids. The relative & absolute mV measurement modes are possible with this pocket ORP meter.

Buy Now View Catalog
Sensor type Platinum sensor
Connector 6 pin
ORP measurement range (-999) to 999 mV
ORP accuracy ± 2 mV
ORP resolution 1 mV
ORP calibration solutions mV & relative mV
ORP calibration points 1 point (only for relative mV mode)
Data hold function Manual or automatic endpoint detection
Reset function Yes
Display LCD screen
Power off Manual or automatic (8 minutes after last key is pressed)
Power 2 × 1.5V “AAA” batteries
Battery life 200 hours
Dimension (L*dia.) 175 × 40 mm
Weight 100 g
  • Equipped with a platinum sensor
    Equipped with 6 pin connector
    1 point offset calibration for adjusting display value to known standards
    Auto hold function freezes stable, final readings for better viewing and recording
    Automatic power off helps to reduce battery power consumption
    Reset function automatically resumes all the setting back to factory default options
    Waterproof features guarantees protection against harsh conditions
ORP electrode
AAA batteries
Carrying case
Plastic storage bottles
High purity platinum electorde

Pocket ORP tester can be used for measurement of chromate reduction, cyanide oxidation, redox & oxidation reaction content in swimming pool water, aquaculture industry and drinking water.

{"Sensor type":"Platinum sensor","Connector":"6 pin","ORP measurement range":"(-999) to 999 mV","ORP accuracy":"\u00b1 2 mV","ORP resolution":"1 mV","ORP calibration solutions":"mV & relative mV","ORP calibration points":"1 point (only for relative mV mode)","Data hold function":"Manual or automatic endpoint detection","Reset function":"Yes","Display":"LCD screen","Power off":"Manual or automatic (8 minutes after last key is pressed)","Power":"2 \u00d7 1.5V \u201cAAA\u201d batteries","Battery life":"200 hours","Dimension (L*dia.)":"175 \u00d7 40 mm","Weight":"100 g"}
Equipped with a platinum sensor
Equipped with 6 pin connector
1 point offset calibration for adjusting display value to known standards
Auto hold function freezes stable, final readings for better viewing and recording
Automatic power off helps to reduce battery power consumption
Reset function automatically resumes all the setting back to factory default options
Waterproof features guarantees protection against harsh conditions
Pocket ORP tester can be used for measurement of chromate reduction, cyanide oxidation, redox & oxidation reaction content in swimming pool water, aquaculture industry and drinking water.


Related Products of ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Pocket ORP tester LPOT-A11

Pocket ORP tester LPOT-A11

Connector : BNC

ORP measurement range : (-999) to 999 mV

ORP accuracy : ± 2 mV

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter LMPWM-A31

pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Multi-parameter Water Quality Meter LMPWM-A30

pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11
Ion measurement range F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Cl, LBIM-A10
Ion measurement range Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1

Benchtop Conductivity Meter LBCM-A13

Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10
Water hardness range 0.05 mmol / L -0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A11
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L

Benchtop Dissolved oxygen meter LBDO-A10

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L

Talk to us?