Benchtop pH meter LBPM-A11 comes with 0.0 to 14.00 pH range is suitable for daily measurements, testing. Automatic calibration can be performed at 2 points using standard USA or NIST pH buffers. It offers automatic or manual temperature compensation of pH measurements. The pH meter with sleek design has easy to read backlit LCD screen that display pH measurements & temperature simultaneously.
Buy Now View CatalogpH measurement range | 0.00 to 14.00 pH |
pH accuracy | ± 0.01 pH |
pH resolution | 0.01 pH |
Calibration points | 2 points |
Calibration solutions | USA (pH 4.0/7.00/10.01) |
ORP measurement range | |
ORP accuracy | |
ORP calibration points | |
ORP calibration range | |
ORP calibration solutions | |
Temperature compensation | 0 to 100°C |
Compensation mode | Manual or automatic |
mV range | -1999 to 1999 mV |
mV accuracy | ±1mV |
mV resolution | 1 mV |
Temperature range | 0 to 100°C, 32 to 212°F |
Temperature accuracy | ±1°C |
Stability conditions | |
Calibration due | |
memory | |
Output | |
Temperature resolution | 1°C |
Hold function | |
Power off | |
Reset function | |
Connector | BNC |
Display | LCD |
Dimension (L*W*H) | 210×205×65 mm |
Weight | 1.5 kg |
Power | DC9V, Ac adapter, AC220V /50Hz |
The benchtop pH meter can be used for daily measurement of pH & temperature at schools, colleges & research laboratories & water testing plants.
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
pH measurement range : -2.000 to 20.000 pH
pH accuracy : ± 0.002 pH
Calibration points : 1-5 points
pH measurement range : -1.00 to 15.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Temperature compensation : 0 to 100°C, 32°F to 212°F Manual or Automatic
Hold function : Manual or automatic endpoint detection
Stability criteria : Standard or High-accuracy
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Ion measurement range | Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Ion measurement range | F range: 1 × 106M – saturation, 0.02 ppm to saturation |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Conductivity measurement range | 0.000 μS/cm to 3000mS/cm |
Resistivity measurement range | 5.00 Ω·cm to 100.0 MΩ·cm |
TDS measurement range | 0.000 mg/L to 1000g/L |
Conductivity measurement range | 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
Conductivity accuracy | ± 1 % F.S. |
Conductivity resolution | 0.01, 0.1, 1 |
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Water hardness range |
0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f |
Accuracy | ± 1 % F.S. |
Calibration points | 2 to 5 points |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.2 mg / L |
Resolution | 0.01 mg / L |
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Resolution | 0.1 mg / L |