Benchtop pH meter LBPM-B10

Benchtop pH meter LBPM-B10 comes with -2.000 to 20.000 pH range and is suitable for daily pH measurement, testing. 1 to 5 points push button calibration is performed using standard USA or NIST pH buffers & 1 point calibration to measure ORP. It offers automatic or manual temperature compensation mode of pH measurements. The pH meter with sleek design has easy to read backlit LCD screen which shows pH measurements & temperature simultaneously.

Buy Now View Catalog
pH measurement range -2.000 to 20.000 pH
pH accuracy ± 0.002 pH
pH resolution
Calibration points 1-5 points
Calibration solutions USA, NIST, DIN or user defined
ORP measurement range -1999.9 to 1999.9 mV
ORP accuracy ±0.2 mV
ORP calibration points 1 point
ORP calibration range ±200 mV
ORP calibration solutions mV & relative mV
Temperature compensation 0 to 100°C, 32 to 212°F
Compensation mode Manual or automatic
mV range
mV accuracy
mV resolution
Temperature range
Temperature accuracy
Stability conditions Low or high
Calibration due 0 to 31 days
memory Stores up to 500 data sets
Output USB communication interface
Temperature resolution
Hold function
Power off
Reset function
Connector BNC
Display LCD
Dimension (L*W*H) 210×188×60 mm
Weight 1.5 kg
Power DC5V using AC adapter, AC220V /50 Hz
  • pH Mode Features:
    Equipped with white backlit LCD display
    pH measurement range -2.000 to 20.000 pH
    1 to 5 points push button calibration to automatically identify pH buffer
    Automatic electrode slope display, helps the operator when to replace the sensor
    Automatic temperature compensation for accurate measured value over the entire range
    Universal BNC connector
    Built-in solution holder
    ORP Mode Features:
    ORP measurement range -1999.9 to 1999.9 mV
    Single point offset calibration to adjust the display value to a known standard
    Relative & absolute mV measurements for accurate ORP readings
    Common Features:
    Calibration due reminder informs operator to calibrate the meter regularly
    Stability indicator displays the status of current measurement
    Auto hold function freezes stable, final readings for better viewing and recording
    Manual temperature calibration to rectify the deviations in temperature
    Automatic temperature compensation for accurate measured value over the entire range
    Selectable temperature units (°C or °F) for different application requirements
    Expanded memory stores and recalls up to 500 readings
    Help message as an operational guide, helps users for quick access to the parameters
    Reset function automatically resumes all the setting back to factory default options
    Store data is transferrable into computer via USB communication interface
BNC pH Electrode
Temperature probe
pH buffer pouches (pH 4.01/7.00/10.01)
USB cable
Dc5V power adapter
pH Electrode
pH buffer pouches (pH 4.01/6.98/9.18) NIST
pH buffer pouches (pH 4.01/7.00/10.01) USA
Temperature probe

The benchtop pH meter can be used for daily measurement of pH, ORP & temperature at schools, colleges & research laboratories & water testing plants.

{"pH measurement range":"-2.000 to 20.000 pH","pH accuracy":"\u00b1 0.002 pH","pH resolution":"","Calibration points":"1-5 points","Calibration solutions":"USA, NIST, DIN or user defined","ORP measurement range":"-1999.9 to 1999.9 mV","ORP accuracy":"\u00b10.2 mV","ORP calibration points":"1 point","ORP calibration range":"\u00b1200 mV","ORP calibration solutions":"mV & relative mV","Temperature compensation":"0 to 100\u00b0C, 32 to 212\u00b0F","Compensation mode":"Manual or automatic","mV range":"","mV accuracy":"","mV resolution":"","Temperature range":"","Temperature accuracy":"","Stability conditions":"Low or high","Calibration due":"0 to 31 days","memory":"Stores up to 500 data sets","Output":"USB communication interface","Temperature resolution":"","Hold function":"","Power off":"","Reset function":"","Connector":"BNC","Display":"LCD","Dimension (L*W*H)":"210\u00d7188\u00d760 mm","Weight":"1.5 kg","Power":"DC5V using AC adapter, AC220V \/50 Hz"}
pH Mode Features:
Equipped with white backlit LCD display
pH measurement range -2.000 to 20.000 pH
1 to 5 points push button calibration to automatically identify pH buffer
Automatic electrode slope display, helps the operator when to replace the sensor
Automatic temperature compensation for accurate measured value over the entire range
Universal BNC connector
Built-in solution holder
ORP Mode Features:
ORP measurement range -1999.9 to 1999.9 mV
Single point offset calibration to adjust the display value to a known standard
Relative & absolute mV measurements for accurate ORP readings
Common Features:
Calibration due reminder informs operator to calibrate the meter regularly
Stability indicator displays the status of current measurement
Auto hold function freezes stable, final readings for better viewing and recording
Manual temperature calibration to rectify the deviations in temperature
Automatic temperature compensation for accurate measured value over the entire range
Selectable temperature units (°C or °F) for different application requirements
Expanded memory stores and recalls up to 500 readings
Help message as an operational guide, helps users for quick access to the parameters
Reset function automatically resumes all the setting back to factory default options
Store data is transferrable into computer via USB communication interface
The benchtop pH meter can be used for daily measurement of pH, ORP & temperature at schools, colleges & research laboratories & water testing plants.


Related Products of pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop pH meter LBPM-A20

Benchtop pH meter LBPM-A20

pH measurement range : -1.00 to 15.00 pH

pH accuracy : ± 0.01 pH

pH resolution : 0.01 pH

Benchtop pH Meter LBPM-B11

Benchtop pH Meter LBPM-B11

Temperature compensation : 0 to 100°C, 32°F to 212°F Manual or Automatic

Hold function : Manual or automatic endpoint detection

Stability criteria : Standard or High-accuracy

Benchtop pH meter LBPM-A11
Benchtop pH meter LBPM-A11

pH measurement range : 0.00 to 14.00 pH

pH accuracy : ± 0.01 pH

pH resolution : 0.01 pH

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Conductivity Meter LBCM-A13

Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L

Benchtop conductivity meter LBCM-A11

Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A11
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
Benchtop Dissolved oxygen meter LBDO-A10
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter LMPWM-A31

pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Multi-parameter Water Quality Meter LMPWM-A30

pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11
Ion measurement range F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Cl, LBIM-A10
Ion measurement range Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

Water hardness range 0.05 mmol / L -0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points

Talk to us?