Benchtop pH meter LBPM-B10 comes with -2.000 to 20.000 pH range and is suitable for daily pH measurement, testing. 1 to 5 points push button calibration is performed using standard USA or NIST pH buffers & 1 point calibration to measure ORP. It offers automatic or manual temperature compensation mode of pH measurements. The pH meter with sleek design has easy to read backlit LCD screen which shows pH measurements & temperature simultaneously.
Buy Now View CatalogpH measurement range | -2.000 to 20.000 pH |
pH accuracy | ± 0.002 pH |
pH resolution | |
Calibration points | 1-5 points |
Calibration solutions | USA, NIST, DIN or user defined |
ORP measurement range | -1999.9 to 1999.9 mV |
ORP accuracy | ±0.2 mV |
ORP calibration points | 1 point |
ORP calibration range | ±200 mV |
ORP calibration solutions | mV & relative mV |
Temperature compensation | 0 to 100°C, 32 to 212°F |
Compensation mode | Manual or automatic |
mV range | |
mV accuracy | |
mV resolution | |
Temperature range | |
Temperature accuracy | |
Stability conditions | Low or high |
Calibration due | 0 to 31 days |
memory | Stores up to 500 data sets |
Output | USB communication interface |
Temperature resolution | |
Hold function | |
Power off | |
Reset function | |
Connector | BNC |
Display | LCD |
Dimension (L*W*H) | 210×188×60 mm |
Weight | 1.5 kg |
Power | DC5V using AC adapter, AC220V /50 Hz |
The benchtop pH meter can be used for daily measurement of pH, ORP & temperature at schools, colleges & research laboratories & water testing plants.
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
pH measurement range : -1.00 to 15.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Temperature compensation : 0 to 100°C, 32°F to 212°F Manual or Automatic
Hold function : Manual or automatic endpoint detection
Stability criteria : Standard or High-accuracy
pH measurement range : 0.00 to 14.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Conductivity measurement range | 0.000 μS/cm to 3000mS/cm |
Resistivity measurement range | 5.00 Ω·cm to 100.0 MΩ·cm |
TDS measurement range | 0.000 mg/L to 1000g/L |
Conductivity measurement range | 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
Conductivity accuracy | ± 1 % F.S. |
Conductivity resolution | 0.01, 0.1, 1 |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.2 mg / L |
Resolution | 0.01 mg / L |
Dissolved oxygen range | 0.0 to 20.0 mg / L (or ppm) |
Dissolved oxygen accuracy | ± 0.5 mg / L |
Resolution | 0.1 mg / L |
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
pH Mode |
|
||||||||||||||||||
mV Mode |
|
||||||||||||||||||
Conductivity Mode |
|
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Ion measurement range | F range: 1 × 106M – saturation, 0.02 ppm to saturation |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Ion measurement range | Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.
Water hardness range |
0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f |
Accuracy | ± 1 % F.S. |
Calibration points | 2 to 5 points |