| Design |
Modular |
| Measuring range |
0.003 to 100ng/mL |
| Detection limit |
≤ 0.001ug/L |
| Working curve correlation coefficient |
y ≥ 0.999 |
| Relative standard deviation |
c.v ≤ 3% |
| Noise |
<±0.02 mV |
| Zero drift |
<± -0.05 mV |
| Modules |
3 |
| Argon or nitrogen |
purity>0.9999 |
| Power |
220 V, 50 Hz, 100 W |
| Dimension |
435×420×230mm |
| Net weight |
15 kg |
-
High sensitivity and high baseline stability with detection limit of 0.001 ng/ml
Excellent short term and long term accuracy
3 available modules; Peristaltic pump sampler, Gas mercury injection device, Solid pyrolysis mercury injection device
Single chip control peristaltic pump injection for accurate injection and good reproducibility
Gold film absorption method, pyrolysis mercury and direct automatic monitoring of atmospheric mercury content
Pyrolysis furnace, solid mercury sample pyrolysis direct injection measurement, to simplify the measurement process
Particularly suitable for ultra-trace liquid mercury testing
Original plug-in reaction bottle, easy to clean, high reliability and sensitivity
Simple and easy user friendly interface
Fluorescence mercury analyzer finds applications in the determination of water, air, soil, minerals, food and biological samples of trace mercury across environmental monitoring, food hygiene, water, hydrogeology, petrochemical and other departments.
{"Design":"Modular","Measuring range":"0.003 to 100ng\/mL","Detection limit":"\u2264 0.001ug\/L","Working curve correlation coefficient":"y \u2265 0.999","Relative standard deviation":"c.v \u2264 3%","Noise":"<\u00b10.02 mV","Zero drift":"<\u00b1 -0.05 mV","Modules":"3","Argon or nitrogen":"purity>0.9999","Power":"220 V, 50 Hz, 100 W","Dimension":"435\u00d7420\u00d7230mm","Net weight":"15 kg"}
High sensitivity and high baseline stability with detection limit of 0.001 ng/ml
Excellent short term and long term accuracy
3 available modules; Peristaltic pump sampler, Gas mercury injection device, Solid pyrolysis mercury injection device
Single chip control peristaltic pump injection for accurate injection and good reproducibility
Gold film absorption method, pyrolysis mercury and direct automatic monitoring of atmospheric mercury content
Pyrolysis furnace, solid mercury sample pyrolysis direct injection measurement, to simplify the measurement process
Particularly suitable for ultra-trace liquid mercury testing
Original plug-in reaction bottle, easy to clean, high reliability and sensitivity
Simple and easy user friendly interface
Fluorescence mercury analyzer finds applications in the determination of water, air, soil, minerals, food and biological samples of trace mercury across environmental monitoring, food hygiene, water, hydrogeology, petrochemical and other departments.