Horizontal Autoclave LHA-I14

Horizontal Autoclave LHA-I14 is a PLC system controlled fully automatic horizontal vacuum sterilizer, offers 180 L capacity with 150°C design temperature and 0.26 MPa of design pressure. With built-in high quality water ring pump and internal circulation structure, features automatic process of pulsation, temperature rise, sterilization and drying. Designed with SUS304 stainless steel chamber, touch screen display and multiple protective devices, has unique pulsating vacuum procedure for drying. Equipped with anti-dry burning device and fault alarm system, has cycle counting function and beep prompts along with a micro-printer for whole process data recording.

Buy Now View Catalog
Capacity 180 L
Design Temperature 150°C
Design Pressure 0.26 MPa
Sterilization Temperature Range 108 to 136°C
Temperature Display Accuracy 0.1°C
Temperature Uniformity ≤ ± 0.5°C
Maximum Working Pressure 0.23 MPa
Display Touch Screen
Controller PLC control system
Protection Devices Anti-dry burning device; Over-temperature; Over pressure; Door mechanical pressure interlock device
Parameter Settings Automatic
Chamber Material SUS304 stainless steel chamber
Water Source Distilled Water/ Tap Water
Power Supply 380 V, 50 Hz
Power 10.2 kW
Chamber Dimension (Φ×L) 500×910 mm
Dimension (L×W×H) 1180×655×1550 mm
Net Weight 360 kg
  • PLC system controlled fully automatic horizontal vacuum sterilizer with 180 L capacity
    150°C design temperature and 0.26 MPa of design pressure, ensures precise sterilization
    Built-in high quality water ring pump and internal circulation structure, optimal results
    Automatic process of pulsation, temperature rise, sterilization and drying
    SUS304 stainless steel chamber, long life-span with easy maintenance and cleaning
    Touch screen display, easy and convenient setting and monitoring of different parameters
    Multiple protective devices, ensures safety of user and prolonged equipment lifespan
    Unique pulsating vacuum procedure for drying, suitable for heat-sensitive material
    Anti-dry burning device, automatically display alarm information for low water level
    Fault alarm system, displays fault information in real-time
    Cycle counting function, to autoclaving large volumes of liquid in a timely manner
    Beep prompts on completion of sterilization cycle
    Micro-printer for whole process data recording, ensures easy data processing and analysis
    High-efficient, stable and reliable unit with precise and accurate operation

Horizontal Autoclave is used to sterilize the packed, the unpacked, the solid instruments, the hollow (class A and class B) instruments, the instruments with pipelines, the implants and the other high-temperature and high-pressure resistance articles across the dental departments, the ophthalmology departments, the operating rooms, the laboratories, etc.

{"Capacity":"180 L","Design Temperature":"150\u00b0C","Design Pressure":"0.26 MPa","Sterilization Temperature Range":"108 to 136\u00b0C","Temperature Display Accuracy":"0.1\u00b0C","Temperature Uniformity":"\u2264 \u00b1 0.5\u00b0C","Maximum Working Pressure":"0.23 MPa","Display":"Touch Screen","Controller":"PLC control system","Protection Devices":"Anti-dry burning device; Over-temperature; Over pressure; Door mechanical pressure interlock device","Parameter Settings":"Automatic","Chamber Material":"SUS304 stainless steel chamber","Water Source":"Distilled Water\/ Tap Water","Power Supply":"380 V, 50 Hz","Power":"10.2 kW","Chamber Dimension (\u03a6\u00d7L)":"500\u00d7910 mm","Dimension (L\u00d7W\u00d7H)":"1180\u00d7655\u00d71550 mm","Net Weight":"360 kg"}
PLC system controlled fully automatic horizontal vacuum sterilizer with 180 L capacity
150°C design temperature and 0.26 MPa of design pressure, ensures precise sterilization
Built-in high quality water ring pump and internal circulation structure, optimal results
Automatic process of pulsation, temperature rise, sterilization and drying
SUS304 stainless steel chamber, long life-span with easy maintenance and cleaning
Touch screen display, easy and convenient setting and monitoring of different parameters
Multiple protective devices, ensures safety of user and prolonged equipment lifespan
Unique pulsating vacuum procedure for drying, suitable for heat-sensitive material
Anti-dry burning device, automatically display alarm information for low water level
Fault alarm system, displays fault information in real-time
Cycle counting function, to autoclaving large volumes of liquid in a timely manner
Beep prompts on completion of sterilization cycle
Micro-printer for whole process data recording, ensures easy data processing and analysis
High-efficient, stable and reliable unit with precise and accurate operation
Horizontal Autoclave is used to sterilize the packed, the unpacked, the solid instruments, the hollow (class A and class B) instruments, the instruments with pipelines, the implants and the other high-temperature and high-pressure resistance articles across the dental departments, the ophthalmology departments, the operating rooms, the laboratories, etc.


Related Products of Horizontal Autoclave

Horizontal autoclaves manufactured by us are designed with two pressure gauges to indicate inner and interlayer pressure with interlock device for safety. These units are composed of corrosion resistant stainless steel and equipped with silicon rubber to prevent steam leakage.

Horizontal Laboratory Autoclave LHA-D10

Horizontal Laboratory Autoclave LHA-D10

Capacity : 250 L

Sterilization Temperature : 139 °C

Sterilization Pressure : 0.22MPa

Horizontal Laboratory Autoclave LHA-B10

Horizontal Laboratory Autoclave LHA-B10

Capacity : 150 L

Sterilization Temperature : 134 °C

Sterilization Pressure : 0.22 MPa

Horizontal Laboratory Autoclave LHA-F14
Horizontal Laboratory Autoclave LHA-F14

Capacity : 1200 L

Sterilization Temperature : 139 °C

Sterilization Pressure : 0.25MPa

Horizontal Laboratory Autoclave LHA-F10
Horizontal Laboratory Autoclave LHA-F10

Capacity : 250 L

Sterilization Temperature : 139 °C

Sterilization Pressure : 0.25MPa

Horizontal Autoclave LHA-I10

Horizontal Autoclave LHA-I10

Capacity : 60 L

Design Temperature : 150°C

Design Pressure : 0.26 MPa

Horizontal Laboratory Autoclave LHA-H11

Horizontal Laboratory Autoclave LHA-H11

Capacity : 200 L

Sterilization Temperature : 134 °C

Sterilization Pressure : 0.22 Mpa

Horizontal Laboratory Autoclave LHA-D15
Horizontal Laboratory Autoclave LHA-D15

Capacity : 1500 L

Sterilization Temperature : 139 °C

Sterilization Pressure : 0.22MPa

Horizontal Laboratory Autoclave LHA-A10
Horizontal Laboratory Autoclave LHA-A10

Capacity : 300 L

Sterilization Temperature : 134 °C

Sterilization Pressure : 0.22 Mpa

Portable autoclave

Portable Autoclave LPOA-A12

Volume of Chamber 24 L
Working temperature 126 ℃
Heating mode Electrically / LPG heated

Portable Autoclave LPOA-A11

Volume of Chamber 18 L
Working temperature 126 ℃
Heating mode Electrically / LPG heated

Plasma Autoclave

Plasma Autoclave LPA-A11
Capacity 120 L
Door type Rectangular, single door
Chamber material Anti rust aluminum alloy
Plasma Autoclave LPA-A10
Capacity 80 L
Door type Rectangular, single door
Chamber material Anti rust aluminum alloy

Ethylene Oxide Sterilizer

Ethylene Oxide Sterilizer LEOS-A10

Type Vertical; constant temperature heating box type
Door opening Manual
Capacity 80 L

Ethylene Oxide Sterilizer LEOS-A11

Type Vertical; constant temperature heating box type
Door opening Manual
Capacity 120 L

Medical Autoclave

We offer Medical autoclave with user-friendly features which will not only sterilize the medical tools but can also be used for sterilizing medical waste prior to disposal with respect to the standards of municipal solid waste management.

Medical Autoclave LMA-A11
Capacity 17 L
Sterilization Time 4 - 18 mins
Sterilization Temperature 121 °C / 134 °C
Medical Autoclave LMA-A10
Capacity 14 L
Sterilization Time 4 - 18 mins
Sterilization Temperature 121 °C / 134 °C

Table Top Autoclave

We deliver a wide range of Table Top autoclaves with user-friendly operating system and a capacity ranging from 20L to 50L. These are highly accurate, reliable and in compliance with Class N European Standards.

Tabletop Laboratory Autoclave LTTA-A12

Capacity 35 L
Sterilization Temperature 134 °C
Adjustment temperature 105 to 134 °C

Tabletop Laboratory Autoclave LTTA-A11

Capacity 24 L
Sterilization Temperature 134 °C
Adjustment temperature 105 to 134 °C