Overview
Benchtop Multi-parameter Water Quality Meter LMPWM-A40 with 7 inch TFT display measures pH, mV, relative mV, water hardness, and temperature and Ion concentration of the sample. With expanded memory, it stores and recalls up to 1000 readings. Calibration due reminder informs operator to calibrate the meter regularly.
Features :
Common features
Auto read feature to lock and read endpoint measurement
Stability indicator to record stable measurement reading
Reset feature automatically sets all function to default condition
Automatic interval readings, sends the measurement data to the computer/printer
USB communication interface to transfer store data
pH features
1-5 points push button calibration to automatically identify pH buffer
Convenient to select pH buffer standard (USA/NIST/DIN) or custom calibration solutions
Automatic temperature compensation, provides accurate readings over entire pH range
Automatic electrode diagnosis with pH slope, offset display
Alarm when pH readings are out of range
ORP features
1 point offset calibration, can adjust display value to known standard
Relative and absolute millivolt mode of measurement
Water Hardness features 2 to 5 points calibration with high to low concentration
Advanced measurements using different measurement units
Ion features 2 to 5 2 to 5 points calibration, when 8 concentration points are selected
Different concentration units like ppm, mg/l, mol/l, mmol/l for selection
Automatic recognition of ion selective electrode
Different Ion measurement methods for selection
Calibration report with details of calibration standard and slope
Specifications :
| pH Mode |
| pH range |
-2.00 to 20.00 pH |
| pH Accuracy |
± 0.002 pH |
| pH Resolution |
0.1/0.01/0.001 pH, selectable |
| pH Calibration Points |
1 to 5 Points |
| pH Buffer Solutions |
USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
|
| ORP Mode |
| mV Range |
± 2000 mV |
| mV Accuracy |
± 0.2 mV |
| mV Resolution |
0.1 mV, selectable |
| mV Calibration Points |
1 Point, only for relative mode |
|
| mV Mode |
|
| Ion Mode |
| Ion measurement range |
0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection) |
| Ion measurement accuracy |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
| Ion measurement resolution |
0.001/0.01/0.1/1 |
| Ion measurement calibration points |
2 to 5 points |
| Ion measurement calibration solutions |
0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L |
| Ion measurement methods |
Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction |
|
| Water Hardness Mode |
| Water hardness measurement range |
0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3) |
| Water hardness measurement accuracy |
±1% F.S |
| Water hardness measurement resolution |
0.001/0.01/0.1/1 |
| Water hardness calibration points |
2 to 5 points |
| Water hardness calibration solutions |
0.01/0.1/1/10/100 mmol/L |
|
| Temperature Mode |
| Temperature measurement range |
0 to 105°, 32 to 212°F |
| Temperature measurement accuracy |
± 0.5°C, ± 0.9°F |
| Temperature measurement resolution |
0.1°C, 0.1°F |
| Temperature measurement calibration points |
1 point |
|
| Conductivity Mode |
|
| TDS Mode |
|
| Salinity Mode |
|
| Resistivity Mode |
|
| Dissolved Oxygen Mode |
|
| Temperature Range |
0 to 100°C, 32 to 221°F |
| Temperature Accuracy |
|
| Temperature Resolution |
|
| Temperature Calibrations Points |
|
| Temperature Compensation Mode |
Manual or Automatic |
| Data Hold Function |
Manual or Automatic end point detection |
| Stability Criteria |
Standard or high accuracy |
| Calibration Due Alarm |
1 to 31 days |
| Reset Function |
Yes |
| Memory |
Stores up to 1000 sets data |
| Output |
USB communication interface |
| Connector |
BNC Connector |
| Display |
7 inch TFT LCD display |
| Power supply |
DC 12 V, AC adapter, AC 220 V, 50 Hz |
| Dimension (L × W × H) |
240 × 220 × 80 mm |
| Weight |
1.7 kg |
Standard Accessories :
| Accessories No. |
Name |
| 1 |
pH electrode |
| 2 |
Temperature probe |
| 3 |
pH buffer pouches (4.01/7.00/10.01) |
| 4 |
Ion selective electrode |
| 5 |
Ion calibration standard solution 100 and 1000 ppm |
| 6 |
Water hardness electrode |
| 7 |
Water hardness calibration solutions |
| 8 |
Electrode holder |
| 9 |
Power adapter |
Optional Accessories :
| Accessories No. |
Name of the Ion electrode |
Range |
| 1 |
NH4 [Ammonium] Electrode |
5 × 10-6 ~1M |
| 2 |
Br [Bromide] Electrode |
5 × 10-6 ~1M |
| 3 |
Ca [Calcium] Electrode |
5 × 10-7 ~1M |
| 4 |
Cl [Chloride] Electrode |
5 × 10-6 ~1M |
| 5 |
Cn [Cyanide] Electrode |
5 × 10-6 ~0.01M |
| 6 |
F [Fluoride] Electrode |
1 × 10-6 M~Saturation |
| 7 |
NO3 [Nitrate] Electrode |
7 × 10-6 ~1M |
| 8 |
Ag [Silver] Electrode |
1 × 10-7 ~1M |
| 9 |
Na [Sodium[ Electrode |
1 × 10-5 ~1M |
| 10 |
Cd [Cadmium] Electrode |
1 × 10-6 ~0.1M |
| 11 |
Cu [Cupric] Electrode |
1 × 10-8 ~0.1M |
| 12 |
I [Iodide] Electrode |
5 × 10-8 ~1M |
| 13 |
Pb [Lead[ Electrode |
1 × 10-8 ~0.1M |
| 14 |
K [Potassium] Electrode |
1 × 10-6 ~1M |
| 15 |
S [Sulphide] Electrode |
1 × 10-7 ~1M |
| 16 |
NH3 [Ammonia] Electrode |
1 × 10-6 ~1M |
Applications :
Used in multi-parameters based research testing , and quality analysis of water, other general liquids across water plants, food and beverages production units, laboratories, and institutes.
-