Benchtop Multi-parameter Water Quality Meter LMPWM-A40

Benchtop Multi-parameter Water Quality Meter LMPWM-A40 with 7 inch TFT display measures pH, mV, relative mV, water hardness, and temperature and Ion concentration of the sample. With expanded memory, it stores and recalls up to 1000 readings. Calibration due reminder informs operator to calibrate the meter regularly.

Buy Now View Catalog
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
ORP Mode
mV Range ± 2000 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1 mV, selectable
mV Calibration Points 1 Point, only for relative mode
mV Mode
Ion Mode
Ion measurement range 0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection)
Ion measurement accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent)
Ion measurement resolution 0.001/0.01/0.1/1
Ion measurement calibration points 2 to 5 points
Ion measurement calibration solutions 0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L
Ion measurement methods Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction
Water Hardness Mode
Water hardness measurement range 0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3)
Water hardness measurement accuracy ±1% F.S
Water hardness measurement resolution 0.001/0.01/0.1/1
Water hardness calibration points 2 to 5 points
Water hardness calibration solutions 0.01/0.1/1/10/100 mmol/L
Temperature Mode
Temperature measurement range 0 to 105°, 32 to 212°F
Temperature measurement accuracy ± 0.5°C, ± 0.9°F
Temperature measurement resolution 0.1°C, 0.1°F
Temperature measurement calibration points 1 point
Conductivity Mode
TDS Mode
Salinity Mode
Resistivity Mode
Dissolved Oxygen Mode
Temperature Range 0 to 100°C, 32 to 221°F
Temperature Accuracy
Temperature Resolution
Temperature Calibrations Points
Temperature Compensation Mode Manual or Automatic
Data Hold Function Manual or Automatic end point detection
Stability Criteria Standard or high accuracy
Calibration Due Alarm 1 to 31 days
Reset Function Yes
Memory Stores up to 1000 sets data
Output USB communication interface
Connector BNC Connector
Display 7 inch TFT LCD display
Power supply DC 12 V, AC adapter, AC 220 V, 50 Hz
Dimension (L × W × H) 240 × 220 × 80 mm
Weight 1.7 kg
  • Common features Auto read feature to lock and read endpoint measurement
    Stability indicator to record stable measurement reading
    Reset feature automatically sets all function to default condition
    Automatic interval readings, sends the measurement data to the computer/printer
    USB communication interface to transfer store data
    pH features 1-5 points push button calibration to automatically identify pH buffer
    Convenient to select pH buffer standard (USA/NIST/DIN) or custom calibration solutions
    Automatic temperature compensation, provides accurate readings over entire pH range
    Automatic electrode diagnosis with pH slope, offset display
    Alarm when pH readings are out of range
    ORP features 1 point offset calibration, can adjust display value to known standard
    Relative and absolute millivolt mode of measurement
    Water Hardness features 2 to 5 points calibration with high to low concentration
    Advanced measurements using different measurement units
    Ion features 2 to 5 2 to 5 points calibration, when 8 concentration points are selected
    Different concentration units like ppm, mg/l, mol/l, mmol/l for selection
    Automatic recognition of ion selective electrode
    Different Ion measurement methods for selection
    Calibration report with details of calibration standard and slope
Accessories No. Name
1 pH electrode
2 Temperature probe
3 pH buffer pouches (4.01/7.00/10.01)
4 Ion selective electrode
5 Ion calibration standard solution 100 and 1000 ppm
6 Water hardness electrode
7 Water hardness calibration solutions
8 Electrode holder
9 Power adapter
Accessories No. Name of the Ion electrode Range
1 NH4 [Ammonium] Electrode 5 × 10-6 ~1M
2 Br [Bromide] Electrode 5 × 10-6 ~1M
3 Ca [Calcium] Electrode 5 × 10-7 ~1M
4 Cl [Chloride] Electrode 5 × 10-6 ~1M
5 Cn [Cyanide] Electrode 5 × 10-6 ~0.01M
6 F [Fluoride] Electrode 1 × 10-6 M~Saturation
7 NO3 [Nitrate] Electrode 7 × 10-6 ~1M
8 Ag [Silver] Electrode 1 × 10-7 ~1M
9 Na [Sodium[ Electrode 1 × 10-5 ~1M
10 Cd [Cadmium] Electrode 1 × 10-6 ~0.1M
11 Cu [Cupric] Electrode 1 × 10-8 ~0.1M
12 I [Iodide] Electrode 5 × 10-8 ~1M
13 Pb [Lead[ Electrode 1 × 10-8 ~0.1M
14 K [Potassium] Electrode 1 × 10-6 ~1M
15 S [Sulphide] Electrode 1 × 10-7 ~1M
16 NH3 [Ammonia] Electrode 1 × 10-6 ~1M

Used in multi-parameters based research testing , and quality analysis of water, other general liquids across water plants, food and beverages production units, laboratories, and institutes.

{"pH Mode":"\n \n \n \n \n \n
pH range <\/td>\n -2.00 to 20.00 pH<\/td>\n <\/tr>\n
pH Accuracy <\/td>\n \u00b1 0.002 pH<\/td>\n <\/tr>\n
pH Resolution <\/td>\n 0.1\/0.01\/0.001 pH, selectable<\/td>\n <\/tr>\n
pH Calibration Points <\/td>\n 1 to 5 Points<\/td>\n <\/tr>\n
pH Buffer Solutions <\/td>\n USA (pH 4.0\/7.00\/10.01) or NIST (pH 4.01\/6.86\/9.18) or DIN buffers<\/td>\n <\/tr>\n <\/table>","ORP Mode":"\n \n \n \n \n
mV Range <\/td>\n \u00b1 2000 mV<\/td>\n <\/tr>\n
mV Accuracy <\/td>\n \u00b1 0.2 mV<\/td>\n <\/tr>\n
mV Resolution <\/td>\n 0.1 mV, selectable<\/td>\n <\/tr>\n
mV Calibration Points<\/td>\n 1 Point, only for relative mode<\/td>\n <\/tr>\n <\/table>","mV Mode":"","Ion Mode":"\n \n \n \n \n \n \n
Ion measurement range <\/td>\n 0.01 to 30000 ppm, mg\/l, mol\/l, mmol\/l (refer Range of ion selection) <\/td>\n <\/tr>\n
Ion measurement accuracy<\/td>\n \u00b10.5% F.S (Monovalent), \u00b11% F.S (Divalent)<\/td>\n <\/tr>\n
Ion measurement resolution<\/td>\n 0.001\/0.01\/0.1\/1<\/td>\n <\/tr>\n
Ion measurement calibration points<\/td>\n 2 to 5 points<\/td>\n <\/tr>\n
Ion measurement calibration solutions<\/td>\n 0.001\/0.01\/0.1\/1\/10\/100\/1000\/10000 ppm, mg\/L, mol\/L<\/td>\n <\/tr>\n
Ion measurement methods<\/td>\n Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction<\/td>\n <\/tr>\n <\/table>","Water Hardness Mode":"\n \n \n \n \n \n
Water hardness measurement range <\/td>\n 0.05-200mmol\/L, 0-1120\u00b0dH, 0-1404\u00b0e, 0-2000\u00b0fH, 0-8000mg\/L (Ca2+), 0~19999mg\/L (CaCO3)<\/td>\n <\/tr>\n
Water hardness measurement accuracy<\/td>\n \u00b11% F.S<\/td>\n <\/tr>\n
Water hardness measurement resolution<\/td>\n 0.001\/0.01\/0.1\/1<\/td>\n <\/tr>\n
Water hardness calibration points<\/td>\n 2 to 5 points<\/td>\n <\/tr>\n
Water hardness calibration solutions<\/td>\n 0.01\/0.1\/1\/10\/100 mmol\/L<\/td>\n <\/tr>\n <\/table>","Temperature Mode":"\n \n \n \n \n
Temperature measurement range <\/td>\n 0 to 105\u00b0, 32 to 212\u00b0F<\/td>\n <\/tr>\n
Temperature measurement accuracy<\/td>\n \u00b1 0.5\u00b0C, \u00b1 0.9\u00b0F<\/td>\n <\/tr>\n
Temperature measurement resolution<\/td>\n 0.1\u00b0C, 0.1\u00b0F<\/td>\n <\/tr>\n
Temperature measurement calibration points<\/td>\n 1 point<\/td>\n <\/tr>\n <\/table>","Conductivity Mode":"","TDS Mode":"","Salinity Mode":"","Resistivity Mode":"","Dissolved Oxygen Mode":"","Temperature Range":"0 to 100\u00b0C, 32 to 221\u00b0F","Temperature Accuracy":"","Temperature Resolution":"","Temperature Calibrations Points":"","Temperature Compensation Mode":"Manual or Automatic","Data Hold Function":"Manual or Automatic end point detection","Stability Criteria":"Standard or high accuracy","Calibration Due Alarm":"1 to 31 days","Reset Function":"Yes","Memory":"Stores up to 1000 sets data","Output":"USB communication interface","Connector":"BNC Connector","Display":"7 inch TFT LCD display","Power supply":"DC 12 V, AC adapter, AC 220 V, 50 Hz","Dimension (L \u00d7 W \u00d7 H)":"240 \u00d7 220 \u00d7 80 mm","Weight":"1.7 kg"}
Common features Auto read feature to lock and read endpoint measurement
Stability indicator to record stable measurement reading
Reset feature automatically sets all function to default condition
Automatic interval readings, sends the measurement data to the computer/printer
USB communication interface to transfer store data
pH features 1-5 points push button calibration to automatically identify pH buffer
Convenient to select pH buffer standard (USA/NIST/DIN) or custom calibration solutions
Automatic temperature compensation, provides accurate readings over entire pH range
Automatic electrode diagnosis with pH slope, offset display
Alarm when pH readings are out of range
ORP features 1 point offset calibration, can adjust display value to known standard
Relative and absolute millivolt mode of measurement
Water Hardness features 2 to 5 points calibration with high to low concentration
Advanced measurements using different measurement units
Ion features 2 to 5 2 to 5 points calibration, when 8 concentration points are selected
Different concentration units like ppm, mg/l, mol/l, mmol/l for selection
Automatic recognition of ion selective electrode
Different Ion measurement methods for selection
Calibration report with details of calibration standard and slope
Used in multi-parameters based research testing , and quality analysis of water, other general liquids across water plants, food and beverages production units, laboratories, and institutes.


Benchtop Multi-parameter Water Quality Meter LMPWM-A32

Benchtop Multi-parameter Water Quality Meter LMPWM-A32

pH Mode :

pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers

mV Mode :

mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point

Conductivity Mode :

Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Multi-parameter Water Quality Meter LMPWM-A31

Benchtop Multi-parameter Water Quality Meter LMPWM-A31

pH Mode :

pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers

mV Mode :

mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point

Conductivity Mode :

Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Multi-parameter Water Quality Meter LMPWM-A30
Benchtop Multi-parameter Water Quality Meter LMPWM-A30

pH Mode :

pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers

mV Mode :

mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point

Conductivity Mode :

Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

BOD Meter LBOD-A10

Determination range
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error Less or less than 10 %
Sample container/ bottle quantity 1 to 6

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A10

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Benchtop Dissolved oxygen meter LBDO-A11
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10
Water hardness range 0.05 mmol / L -0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Conductivity Meter LBCM-A13

Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L

Benchtop conductivity meter LBCM-A11

Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11
Ion measurement range F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Cl, LBIM-A10
Ion measurement range Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1