Conductivity measurement range |
0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm |
Conductivity accuracy |
± 1 % F.S. |
Conductivity resolution |
0.01, 0.1, 1 |
Conductivity calibration solutions |
10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm |
Conductivity calibration points |
1 - 3 points |
Temperature compensation range & mode |
Manual or automatic, 0 to 100 °C , 32 to 212 °F |
Temperature range |
0 to 105 °C, 32 to 221 °F |
Temperature accuracy |
± 1° |
Temperature resolution |
0.1 °C |
Temperature coefficient |
0.0 to 10.0 % per °C |
Cell constant |
K= 0.1, 1, 10 or User-defined |
Data hold function |
Manual or automatic |
Connector |
6 - pin mini plug |
Display |
LCD (315 × 75 mm) |
Power |
DC 6 V / 400 mA power adapter, AC 220 V / 50Hz |
Dimension (L × W × H) |
210 × 205 × 75 mm |
Weight |
1.5 kg |
-
Equipped with white backlit LCD display
1 - 3 point calibration with automatic recognition of calibration solution
Manual temperature compensation improves the measurement accuracy of meter
Automatic temperature compensation for accurate measured value over the entire range
Auto hold function freezes stable, final readings for better viewing and recording
Reset function automatically resumes all the settings to default mode
System menu allows setting the 6 parameters
Automatic power off helps to reduce battery power consumption
Help message as an operational guide for Quick access to the conductivity meter
Conductivity electrode
Temperature probe
DC 9 V power adapter
Conductivity electrode for pure water
Conductivity electrode for general liquids
Conductivity electrode for high conductivity
Conductivity standard solution 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
The benchtop conductivity meter is used in water quality analysis, research, education, environmental monitoring, chemicals & liquids quality testing etc. for measuring conductivity.
{"Conductivity measurement range":"0 - 20.0, 200.0, 2000 \u00b5S \/ cm, 200.0 mS \/ cm","Conductivity accuracy":"\u00b1 1 % F.S.","Conductivity resolution":"0.01, 0.1, 1","Conductivity calibration solutions":"10 \u00b5S \/ cm , 84 \u00b5S \/ cm, 1413 \u00b5S \/ cm, 12.88 mS \/ cm, 111.8 mS \/ cm","Conductivity calibration points":"1 - 3 points","Temperature compensation range & mode":"Manual or automatic, 0 to 100 \u00b0C , 32 to 212 \u00b0F","Temperature range":"0 to 105 \u00b0C, 32 to 221 \u00b0F","Temperature accuracy":"\u00b1 1\u00b0","Temperature resolution":"0.1 \u00b0C","Temperature coefficient":"0.0 to 10.0 % per \u00b0C","Cell constant":"K= 0.1, 1, 10 or User-defined","Data hold function":"Manual or automatic","Connector":"6 - pin mini plug","Display":"LCD (315 \u00d7 75 mm)","Power":"DC 6 V \/ 400 mA power adapter, AC 220 V \/ 50Hz","Dimension (L \u00d7 W \u00d7 H)":"210 \u00d7 205 \u00d7 75 mm","Weight":"1.5 kg"}
Equipped with white backlit LCD display
1 - 3 point calibration with automatic recognition of calibration solution
Manual temperature compensation improves the measurement accuracy of meter
Automatic temperature compensation for accurate measured value over the entire range
Auto hold function freezes stable, final readings for better viewing and recording
Reset function automatically resumes all the settings to default mode
System menu allows setting the 6 parameters
Automatic power off helps to reduce battery power consumption
Help message as an operational guide for Quick access to the conductivity meter
The benchtop conductivity meter is used in water quality analysis, research, education, environmental monitoring, chemicals & liquids quality testing etc. for measuring conductivity.