Conductivity Mode |
- Conductivity measurement range: 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
- Conductivity accuracy: ±1% F.S.
- Conductivity resolution: 0.001, 0.01, 0.1, 1
- Conductivity calibration points: 1 to 3 points
- Conductivity calibration solutions: 10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
|
TDS Mode |
- TDS measurement Range: 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
- TDS Accuracy: ± 1 % F.S.
- TDS Factor: 0.01 to 1.00 (default 0.5)
- TDS Calibration points: 3 points
|
Temperature Mode |
- Temperature range: 0 to 105°C, 32 to 221°F
- Temperature accuracy: ±1°C
- Temperature resolution: 0.1°C, 0.1°F
- Temperature calibration points: 1 point
- Temperature Compensation Range and Mode: Manual or Automatic, 0 to 100°C , 32 to 212°F
- Temperature coefficient: 0.0 to 10.0 % per °C
|
Cell constant |
K=0.1, 1, 10 |
Power requirements |
DC 9 V, using AC adapter, AC 220 V, 50 Hz |
Dimension (L×W×H) |
210 × 205 × 75 mm |
Weight |
1.5 kg |
-
Measures conductivity, TDS, Temperature of the liquids
Automatic temperature compensation for accurate values over the entire range
Selectable temperature units (°C or °F) for different application requirements
Reset function automatically resumes all the setting back to factory default options
Manual and automatic mode of temperature calibration
Auto hold feature to lock, record and read stable measurement endpoint
Stability indicator displays the status of current measurement
Help message as an operational guide, with quick access to test parameters
Conductivity/TDS Mode
1 to 3 Conductivity push button calibration points
3 TDS calibration points
1 Temperature calibration point
Accessories no. |
Name |
1 |
Conductivity Electrode (range 0.01 to 20 mS/ cm) |
2 |
Temperature Probe |
3 |
Conductivity Calibration Standard Solutions |
4 |
Electrode Holder |
5 |
Power Adapter |
Accessories no. |
Name |
1 |
Conductivity Electrode (K=0.1) suitable for measuring the low conductivity liquids (
<10µS/ cm) e.g. Pure water
|
2 |
Conductivity Electrode (K=10) suitable for measuring the high conductivity liquids (>20mS/ cm) e.g. Sea water |
Used to test Conductivity, TDS values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose
{"Conductivity Mode":{"Conductivity measurement range":"0.01-20.0, 200.0, 2000 \u00b5S\/cm, 20.00, 200.0 mS\/cm","Conductivity accuracy":"\u00b11% F.S.","Conductivity resolution":"0.001, 0.01, 0.1, 1","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm , 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm"},"TDS Mode":{"TDS measurement Range":"0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS Accuracy":"\u00b1 1 % F.S.","TDS Factor":"0.01 to 1.00 (default 0.5)","TDS Calibration points":"3 points"},"Temperature Mode":{"Temperature range":"0 to 105\u00b0C, 32 to 221\u00b0F","Temperature accuracy":"\u00b11\u00b0C","Temperature resolution":"0.1\u00b0C, 0.1\u00b0F","Temperature calibration points":"1 point","Temperature Compensation Range and Mode":"Manual or Automatic, 0 to 100\u00b0C , 32 to 212\u00b0F","Temperature coefficient":"0.0 to 10.0 % per \u00b0C"},"Cell constant":"K=0.1, 1, 10","Power requirements":"DC 9 V, using AC adapter, AC 220 V, 50 Hz","Dimension (L\u00d7W\u00d7H)":"210 \u00d7 205 \u00d7 75 mm","Weight":"1.5 kg"}
Measures conductivity, TDS, Temperature of the liquids
Automatic temperature compensation for accurate values over the entire range
Selectable temperature units (°C or °F) for different application requirements
Reset function automatically resumes all the setting back to factory default options
Manual and automatic mode of temperature calibration
Auto hold feature to lock, record and read stable measurement endpoint
Stability indicator displays the status of current measurement
Help message as an operational guide, with quick access to test parameters
Conductivity/TDS Mode
1 to 3 Conductivity push button calibration points
3 TDS calibration points
1 Temperature calibration point
Used to test Conductivity, TDS values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose