Benchtop Water hardness meter LBWM-A10

Benchtop Water hardness meter LBWM-A10 is equipped with large backlit LCD display, 2 to 5 points calibration with low to high concentration range. The calibration due reminder alerts user for calibration of the meter on regular basis. The System menu allows setting the 7 parameters like stability condition, auto-power off etc. It measure salts of calcium & other elements at mg/L, mmol/ scale which causes hardness water.

Buy Now View Catalog
Water hardness range 0.05 mmol / L -0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Calibration solution 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
Temperature range 0 - 105 °C
Temperature accuracy ± 0.5 °C
Calibration range Measured value ± 10 °C
Temperature compensation range 0 to 50 °C
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Memory Stores up to 500 sets of data
Output USB communication interface
Connector BNC
Power DC5V, using AC adapter, 220V/50Hz
Dimension (L × W × H) 170 × 85 × 30 mm
Weight 1.5 kg
  • Large LCD display
    Two to five points calibration with low to high range
    System menu with 7 parameters setting
    Stability indicator to robotically display current measurements
    Automatic electrode diagnosis shows the slope of sensor
    Calibration due reminder for regular calibration of the meter
    Manual temperature compensation for better measurement accuracy of meter
    Auto hold function freezes stable, final readings for better viewing and recording
    Automatic temperature compensation for accurate measured value over the entire range
    Reset function
    Enlarged memory can store up to 500 sets of data
    Built-in real time clock stamps
    Operational guide for Quick access to the conductivity meter
Water hardness electrode
Temperature probe
Carrying case
Water hardness electrode range 0.00005 to 0.2 M

Benchtop water hardness meter is used in testing the hardness level of tap water, drinking water, filtered water, water used for different experiments and testing across food, textile, painting & other industries.

{"Water hardness range":"0.05 mmol \/ L -0.2 mol \/ L (CaCO3<\/sub>) 0 - 19999 mg \/ L, (CaO) 0 - 11220 mg \/ L, (boiler) 0 - 400 mmol \/ L, (Ca) 0 - 8020 mg \/ L (German degree) 0 - 1122 \u00b0dH, (English degree) 0 - 1404 \u00b0e, (French degree) 0 - 2000 \u00b0f","Accuracy":"\u00b1 1 % F.S.","Calibration points":"2 to 5 points","Calibration solution":"0.001, 0.01, 0.1 mmol\/L, 0.001, 0.01, 0.1 mol\/L","Temperature range":"0 - 105 \u00b0C","Temperature accuracy":"\u00b1 0.5 \u00b0C","Calibration range":"Measured value \u00b1 10 \u00b0C","Temperature compensation range":"0 to 50 \u00b0C","Compensation mode":"Manual or automatic","Data hold function":"Manual or automatic endpoint detection","Reset function":"Yes","Stability condition":"Low or high","Calibration due":"0 to 31 days","Memory":"Stores up to 500 sets of data","Output":"USB communication interface","Connector":"BNC","Power":"DC5V, using AC adapter, 220V\/50Hz","Dimension (L \u00d7 W \u00d7 H)":"170 \u00d7 85 \u00d7 30 mm","Weight":"1.5 kg"}
Large LCD display
Two to five points calibration with low to high range
System menu with 7 parameters setting
Stability indicator to robotically display current measurements
Automatic electrode diagnosis shows the slope of sensor
Calibration due reminder for regular calibration of the meter
Manual temperature compensation for better measurement accuracy of meter
Auto hold function freezes stable, final readings for better viewing and recording
Automatic temperature compensation for accurate measured value over the entire range
Reset function
Enlarged memory can store up to 500 sets of data
Built-in real time clock stamps
Operational guide for Quick access to the conductivity meter
Benchtop water hardness meter is used in testing the hardness level of tap water, drinking water, filtered water, water used for different experiments and testing across food, textile, painting & other industries.


Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for Cl, LBIM-A10

Ion measurement range Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Benchtop Ion meter for F, LBIM-A11

Ion measurement range F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter LMPWM-A30
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
Benchtop Multi-parameter Water Quality Meter LMPWM-A31
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1

Benchtop Conductivity Meter LBCM-A13

Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L

BOD Meter

BOD Meter LBOD-A10
Determination range
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error Less or less than 10 %
Sample container/ bottle quantity 1 to 6

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A10
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L

Benchtop Dissolved oxygen meter LBDO-A11

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L

Talk to us?