Water hardness range |
0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f |
Accuracy |
± 1 % F.S. |
Calibration points |
2 to 5 points |
Calibration solution |
0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L |
Temperature range |
0 - 105 °C |
Temperature accuracy |
± 0.5 °C |
Calibration range |
Measured value ± 10 °C |
Temperature compensation range |
0 to 50 °C |
Compensation mode |
Manual or automatic |
Data hold function |
Manual or automatic endpoint detection |
Reset function |
Yes |
Stability condition |
Low or high |
Calibration due |
0 to 31 days |
Memory |
Stores up to 500 sets of data |
Output |
USB communication interface |
Connector |
BNC |
Power |
DC5V, using AC adapter, 220V/50Hz |
Dimension (L × W × H) |
170 × 85 × 30 mm |
Weight |
1.5 kg |
-
Large LCD display
Two to five points calibration with low to high range
System menu with 7 parameters setting
Stability indicator to robotically display current measurements
Automatic electrode diagnosis shows the slope of sensor
Calibration due reminder for regular calibration of the meter
Manual temperature compensation for better measurement accuracy of meter
Auto hold function freezes stable, final readings for better viewing and recording
Automatic temperature compensation for accurate measured value over the entire range
Reset function
Enlarged memory can store up to 500 sets of data
Built-in real time clock stamps
Operational guide for Quick access to the conductivity meter
Water hardness electrode
Temperature probe
Carrying case
Water hardness electrode range 0.00005 to 0.2 M
Benchtop water hardness meter is used in testing the hardness level of tap water, drinking water, filtered water, water used for different experiments and testing across food, textile, painting & other industries.
{"Water hardness range":"0.05 mmol \/ L -0.2 mol \/ L
(CaCO3<\/sub>) 0 - 19999 mg \/ L, (CaO) 0 - 11220 mg \/ L, (boiler) 0 - 400 mmol \/ L, (Ca) 0 - 8020 mg \/ L
(German degree) 0 - 1122 \u00b0dH, (English degree) 0 - 1404 \u00b0e, (French degree) 0 - 2000 \u00b0f","Accuracy":"\u00b1 1 % F.S.","Calibration points":"2 to 5 points","Calibration solution":"0.001, 0.01, 0.1 mmol\/L, 0.001, 0.01, 0.1 mol\/L","Temperature range":"0 - 105 \u00b0C","Temperature accuracy":"\u00b1 0.5 \u00b0C","Calibration range":"Measured value \u00b1 10 \u00b0C","Temperature compensation range":"0 to 50 \u00b0C","Compensation mode":"Manual or automatic","Data hold function":"Manual or automatic endpoint detection","Reset function":"Yes","Stability condition":"Low or high","Calibration due":"0 to 31 days","Memory":"Stores up to 500 sets of data","Output":"USB communication interface","Connector":"BNC","Power":"DC5V, using AC adapter, 220V\/50Hz","Dimension (L \u00d7 W \u00d7 H)":"170 \u00d7 85 \u00d7 30 mm","Weight":"1.5 kg"}
Large LCD display
Two to five points calibration with low to high range
System menu with 7 parameters setting
Stability indicator to robotically display current measurements
Automatic electrode diagnosis shows the slope of sensor
Calibration due reminder for regular calibration of the meter
Manual temperature compensation for better measurement accuracy of meter
Auto hold function freezes stable, final readings for better viewing and recording
Automatic temperature compensation for accurate measured value over the entire range
Reset function
Enlarged memory can store up to 500 sets of data
Built-in real time clock stamps
Operational guide for Quick access to the conductivity meter
Benchtop water hardness meter is used in testing the hardness level of tap water, drinking water, filtered water, water used for different experiments and testing across food, textile, painting & other industries.