Benchtop Conductivity Meter LBCM-A13

Benchtop Conductivity Meter LBCM-A13 with 7 inch display conducts up to 5 point calibration, automatically recognizes calibration standards. Comes with 03 reading mode: fast, medium, strict, custom to balance the work operations. Complied with GLP specifications, meter allows user to carry data statistics, measure results, carry out and review, analyze, and compare statistics.

Buy Now View Catalog
Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L
Salinity measurement range 0.00 to 8.00 %
Temperature measurement range -5.0 to 135.0 °C
Conductivity accuracy ± 0.5 % FS
Resistivity accuracy ± 0.5 % FS
TDS accuracy ± 0.5 % FS
Salinity accuracy ± 0.1 %
Temperature accuracy ± 0.1  °C
Automatic temperature compensation Yes
Automatic calibration Yes
Automatic range switching Yes
Calibration function Yes
Reading mode
Timed reading Yes
Balanced reading Yes
Continuous reading Yes
Data interface RS232, USB
Data storage 1000 sets
Complied with GLP specifications Yes
Power supply (Input: AC 100 to 240 V, 1.35 A) (Output: DC 24 V, 3A)
Dimension 280 × 280 × 130 mm
Weight 2.5 kg
  • 7 inch color touch screen
    Automatic temperature compensation and calibration
    Electrode correction function
    5 point conductivity calibrations
    Intelligent operating system
    100 sets of measurement data
    Different conductivity compensation methods (includes pure water)
    Different salinity compensation methods (includes saline , brine water)
    Supports USB, RS232 connection with PC, serial printer
    Supports firmware upgrade, support U disk hot swap
Accessories no. Name
1 Conductivity Electrode
2 Temperature sensor
3 Electrode holder
4 AC/DC Power Adapter
5 USB Communication Line
Accessories No. Name
1 Conductivity Probe (K=0.01)
2 Conductivity Probe (K=0.1)
3 Conductivity Probe (K=1)
4 Conductivity Probe (K=10)

Used to test Conductivity, TDS, Salinity, resistivity values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose.

{"Conductivity measurement range":"0.000 \u03bcS\/cm\u00a0to\u00a03000mS\/cm","Resistivity measurement range":"5.00 \u03a9\u00b7cm to 100.0 M\u03a9\u00b7cm","TDS measurement range":"0.000 mg\/L\u00a0to\u00a01000g\/L","Salinity measurement range":"0.00\u00a0to\u00a08.00\u00a0%","Temperature measurement range":"-5.0\u00a0to\u00a0135.0\u00a0\u00b0C","Conductivity accuracy":"\u00b1 0.5 % FS","Resistivity accuracy":"\u00b1 0.5 % FS","TDS accuracy":"\u00b1 0.5 % FS","Salinity accuracy":"\u00b1 0.1 %","Temperature accuracy":"\u00b1 0.1\u00a0 \u00b0C","Automatic temperature compensation":"Yes","Automatic calibration":"Yes","Automatic range switching":"Yes","Calibration function":"Yes","Reading mode":"\n \n \n \n
Timed reading<\/td>\n Yes<\/td>\n <\/tr>\n
Balanced reading<\/td>\n Yes<\/td>\n <\/tr>\n
Continuous reading<\/td>\n Yes<\/td>\n <\/tr>\n <\/table>","Data interface":"RS232, USB","Data storage":"1000 sets","Complied with GLP specifications":"Yes","Power supply":"(Input: AC 100 to 240 V, 1.35 A) (Output: DC 24 V, 3A)","Dimension":"280 \u00d7 280 \u00d7 130 mm","Weight":"2.5 kg"}
7 inch color touch screen
Automatic temperature compensation and calibration
Electrode correction function
5 point conductivity calibrations
Intelligent operating system
100 sets of measurement data
Different conductivity compensation methods (includes pure water)
Different salinity compensation methods (includes saline , brine water)
Supports USB, RS232 connection with PC, serial printer
Supports firmware upgrade, support U disk hot swap
Used to test Conductivity, TDS, Salinity, resistivity values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose.


Related Products of Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

Benchtop conductivity meter LBCM-A11

Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm

Conductivity accuracy : ± 1 % F.S.

Conductivity resolution : 0.01, 0.1, 1

Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

Conductivity Mode :

  • Conductivity measurement range: 0.01-20.0, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
  • Conductivity accuracy: ±1% F.S.
  • Conductivity resolution: 0.001, 0.01, 0.1, 1
  • Conductivity calibration points: 1 to 3 points
  • Conductivity calibration solutions: 10 µS/cm , 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm

TDS Mode :

  • TDS measurement Range: 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)
  • TDS Accuracy: ± 1 % F.S.
  • TDS Factor: 0.01 to 1.00 (default 0.5)
  • TDS Calibration points: 3 points

Temperature Mode :

  • Temperature range: 0 to 105°C, 32 to 221°F
  • Temperature accuracy: ±1°C
  • Temperature resolution: 0.1°C, 0.1°F
  • Temperature calibration points: 1 point
  • Temperature Compensation Range and Mode: Manual or Automatic, 0 to 100°C , 32 to 212°F
  • Temperature coefficient: 0.0 to 10.0 % per °C

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11

Ion measurement range F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Benchtop Ion meter for Cl, LBIM-A10

Ion measurement range Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10
Water hardness range 0.05 mmol / L -0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points
Benchtop Multi-parameter Water Quality Meter LMPWM-A30
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Multi-parameter Water Quality Meter LMPWM-A31

pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A10

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Benchtop Dissolved oxygen meter LBDO-A11
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L
BOD Meter LBOD-A10
Determination range
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error Less or less than 10 %
Sample container/ bottle quantity 1 to 6

Talk to us?