BOD Meter LBOD-A10

BOD Meter LBOD-A10 is a benchtop unit designed to automatically measure B.O.D. (biological oxygen demand) with 0 to 4000 mg/ L measurement range. Simple and safe mercury pressure difference measurement method is applied to prevent poisoning caused by the leakage of the mercury column. Equipped with high end brand mini thermal printer, quickly prints measurement process data, result data. Automatically saves test data on power failure and executes experimental process once power supply is on.

Buy Now View Catalog
Determination range
0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution)
0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error Less or less than 10 %
Sample container/ bottle quantity 1 to 6
Sample container/ bottle Capacity 1000 ml
Repeatability ≤ 10 %
Resolution 0.1 mg
Storage space Test data of 1000 groups
Data record interval 5 to 180 mins adjustable
Measurement period 1 to 30 days adjustable
Display mode 7 inch full color touch LCD screen
Operation mode Touch Screen Full Graphic Human-Computer Interaction Operation
Print mode Heat sensitive line type printing
Communication interface RS232
Power supply 220 V, 50 Hz
Packaging Dimension 500 × 500 × 400 mm
Gross Weight 15 kg
HS Code 902780990
  • Automatic determination of BOD content
    7 inch high end full color LCD touch screen display
    Supports 1 to 6 bottles (samples) at the a time
    Detects up to 6 samples at one time
    Intelligent automatic temperature compensation
    Data curve is drawn automatically without conversion of the BOD concentration value
    Real time data storage
    Supports on-line processing of test data
    User-friendly applications
Accessories no. Name Qty.
1 BOD Glass Bottle 6 units
2 BOD Glass Bottle Cover 6 units
3 Mixing Bar 6 units
4 Test cup 6 units
5 pH test strips 1 pack
6 Data cable 7 units
7 Power line 220 V 1 unit

Used in automatic determination of BOD content in surface water, municipal water, sewage waste water, water testing and quality checking plants and others.

{"Determination range":"\n \n \n
0 to 35 mg\/L, 0 to 70 mg\/ L, 0 to 350 mg\/L, 0 to 700 mg\/L (without dilution)<\/td>\n <\/tr>\n
0 to 4000 mg\/ L (need to dilute) (subsection measurement)<\/td>\n <\/tr>\n <\/table>","Measurement error":"Less or less than 10 %","Sample container\/ bottle quantity":"1 to 6","Sample container\/ bottle Capacity":"1000 ml","Repeatability":"\u2264 10 %","Resolution":"0.1 mg","Storage space":"Test data of 1000 groups","Data record interval":"5 to 180 mins adjustable","Measurement period":"1 to 30 days adjustable","Display mode":"7 inch full color touch LCD screen","Operation mode":"Touch Screen Full Graphic Human-Computer Interaction Operation","Print mode":"Heat sensitive line type printing","Communication interface":"RS232","Power supply":"220 V, 50 Hz","Packaging Dimension":"500 \u00d7 500 \u00d7 400 mm","Gross Weight":"15 kg","HS Code":"902780990"}
Automatic determination of BOD content
7 inch high end full color LCD touch screen display
Supports 1 to 6 bottles (samples) at the a time
Detects up to 6 samples at one time
Intelligent automatic temperature compensation
Data curve is drawn automatically without conversion of the BOD concentration value
Real time data storage
Supports on-line processing of test data
User-friendly applications
Used in automatic determination of BOD content in surface water, municipal water, sewage waste water, water testing and quality checking plants and others.


Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A11

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L

Benchtop Dissolved oxygen meter LBDO-A10

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Benchtop Multi-parameter Water Quality Meter LMPWM-A31
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C
Benchtop Multi-parameter Water Quality Meter LMPWM-A30
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1

Benchtop Conductivity Meter LBCM-A13

Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11
Ion measurement range F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Benchtop Ion meter for Cl, LBIM-A10
Ion measurement range Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

Water hardness range 0.05 mmol / L -0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points

Talk to us?