Semi-automatic Bio-chemistry Analyzer LSBA-A21 also known as chemistry analyzer is a table-top, compact, semi-automated and high performance analyzer offers photometric range from 0 to +3.0 OD with 3 level temperature range along with temperature accuracy of ±0.1˚C. Incorporated with excellent QC function with large memory. Equipped with different wavelengths such as 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm with accuracy of ±2nm. Built-in thermal printer with Real time graph display.
Buy Now View Catalog| Measuring System |
Measuring Range: 0 to 3.0 OD Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear Photometric linearity: ±2% (0 to 3.000 OD) Photometric accuracy: ±1% (0 to 3.000 OD) Carry over: ≤1% |
| Photometric System |
Light source: 6 V, 10 W halogen lamp; standby function Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request) Wavelength Accuracy: ±2 nm |
| Thermostatic Control |
Temperature: 25˚C, 30˚C, 37˚C Precision: ±0.1˚C |
| Drift | <0.005 OD/hr |
| Reading Cuvette | Flow through cell cuvette |
| Measuring Volume | 450 µl to 500 µl |
| Test Menu offered | T.BILI, r-GT/GGT, Ca, APOB-1/B, CHE, D.BILI, ALP/AKP, TG, CL, APOB, CREA, TP, UREA, CK, P, CK-MB, Mg, ALB, LDH, C, ASO, AFU, Lactic Acid, ALT/GPT, UA, α-HBDH, CO2, FMN, LP(a), AST/GOT, GLU, AMY, LDL-C, HDL-C, LA, TBA, ADA, HS-CRP, PA, Fe, Cu, Zn, C3, C4, IgG, IgM, IgA and drug, toxicity etc. |
| Quality Control | QC function with displaying and printing |
| Display | Back illuminated color touch panel; LCD display |
| Storage | Over 200 programs, 1000 test results |
| Printer | Built-in thermal printer |
| Interface | RS-232, USB |
| Power Supply | AC 110 V/ 60 Hz or 220 V/50 Hz |
| Dimension (W×D×H) | 340×380×180 mm |
| Weight | 7 kg |
Semi-automatic Bio-chemistry Analyzer is used across molecular biology, biotechnology, immunology, microbiology, routine biochemistry, hormonal assay, electrolytes, therapeutic drugs and drug-enzyme investigations.
Measuring System : Measuring Range: 0 to 3.0 OD
Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear
Photometric linearity: ±2% (0 to 3.000 OD)
Photometric accuracy: ±1% (0 to 3.000 OD)
Carry over: ≤1%
Photometric System : Light source: 6 V, 10 W halogen lamp; standby function
Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request)
Wavelength Accuracy: ±2 nm
Thermostatic Control : Temperature: 25˚C, 30˚C, 37˚C
Precision: ±0.1˚C
Absorbency Range : -0.3 to 3.0 abs
Resolution : 0.001 abs (display), 0.0001 abs (inner calculation)
Temperature Accuracy : ± 0.1°C
Absorbance Range : 0 to 3.0 Abs
Aspiration Volume : 100 to 5000 µl
Wavelengths : 340 nm, 380 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm and 1 free position