Testing Instruments

Aging Oven TAO-A10
  • The maximum temperature : 300°C
  • Temperature fluctuation : Within ± 0.5°C
  • Temperature uniformity : Within ± 1°C
  • Rotate speed of the turntable : 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Automatic horizontal tensile tester TP-B11
  • Sample (size) length : 90 to 200 mm
  • Sample width : 15 mm, 25 mm, 50mm
  • Measuring range : 0 to 30, 0 to 100 N,0 to 300 N
  • Accuracy : ± 1 %
Automatic horizontal tensile tester TP-B12
  • Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
  • Sample width : 15 mm
  • Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
  • Accuracy : ± 1 %
Bekk Smoothness tester TP-L20
  • Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
  • Accuracy : ±0.1 s within 300 s
  • Vacuum system volume (ml) : Bigger volume: 380 ± 1
    Smaller volume: 38 ± 1
  • Contact pressure : 100 ± 2 kPa
Benchtop gloss meter TBGM-A10
  • Test angle : 60°
  • Gloss aperture : 2 × 3 mm
  • Measurement range : 0 to 1000 GU
  • Repeatability : 0.2 GU (0 to 100 GU), 0.2 % GU (100 to 1000 GU)
Carton compression tester TP-I10
  • Measuring range : 0.1 to 10 kN
  • Indication error : < ± 1%
  • Platen Size : 500×500 mm (customized)
  • Operating stroke : 500 mm (customized)
Carton compression tester TP-I11
  • Measuring range : 1 to 50 kN
  • Indication error : < ± 1%
  • Platen Size : 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
  • Operating stroke : 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Charpy/ Izod Impact Tester TCI-A10
  • Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
  • Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
  • Resolution of impact energy : 0.001 J
  • Pendulum up angle : 160°
COBB sample cutter TP-C30
  • Sample diameter : 125 mm
  • Sample error : ± 0.2 mm
  • Sample Thickness : 0.1 to 1.0 mm
  • Dimension : 240×288×435 mm
Coefficient of friction tester TP-D10
  • Measurement range : 0.01 to 10 N
  • Slider weight : 200 g
  • Slider size : 63×63 mm
  • Testing accuracy : ± 2 %
Crush tester TP-L10
  • Measurement range : 5 to 500 N, 50 to 3000 N
  • Resolution : 1 N
  • Accuracy : ± 1 %
  • Variability : ≤ 1 %
Digital Brinell hardness Tester TDBH-A10
  • Test force : 612.5 N, 980 N, 1225 N
  • Brinell hardness test : 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
  • Hardness measuring area : 8 to 650 HBW (hard metals steel ball)
  • Hardness indication : Digital display
Digital low load Vickers Hardness tester TDVH-A10
  • Test force : 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol : HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display : ± 3.0 %, ± 2.0 %
  • Hardness indication : Digital display
DIN abrasion tester TDAT-A10
  • Test arm weight : 2.5 N
  • Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler : 150 mm
  • Abrasion stroke : 40 ± 0.2 M
Electronic bending stiffness tester TP-E10
  • Testing speed : 200° ± 20° / min
  • Test range : 1 to 10000 mN
  • Indicating Error : ± 1 %
  • Testing length : 5, 10, 15, 20, 25, 50 mm
Electronic Tearing tester TP-J21
  • Capacity : 10 -16000 mN
  • Resolution : 0.1 mN
  • Tearing arm : 104 ± 1 mm
  • Tearing angle : 27.5° ± 5°
Falling Weight Impact Tester TFWT-A10
  • Temperature range : 10 to 35°C
  • Maximum falling height : 2000 mm
  • Resolution of displacement : 1 mm
  • Height error : < ± 2 mm
Folding endurance tester TP-M10
  • Measuring scope : 0 to 99999 s
  • Folding angle : 135° ± 2°
  • Tensile scope : 4.9 to 14.7 N
  • Folding head suture size : 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Heat sealer THS-A10
  • Seal temperature : Room temperature -250°C
  • Control accuracy : ± 0.2°C
  • Dwell time : 0.1 S to 999.9 S
  • Dwell pressure : 0.05 to 0.7 MPa
Ink rubber tester TP-F10
  • Sample size (L*B) : 230×50 mm (can join short samples together)
  • Rub pressure : 20 ± 0.2 N
  • Friction speed : 43 times / min
  • Friction area (L*B) : 155×50 mm
Internal Ply bond Tester TP-J11
  • Capacity : A: 20 to 500 J/m2 B: 500 to 1000 J/m2
  • Impact angle : 90°
  • Unit : Lb-ft/in2  J/m2
  • Error : A: ± 1 J/m2 B: ± 2 J/m2
Lasting adhesive tester TLAT-A10
  • Standard roller : 2000 ± 50 g
  • Testing stations : 3
  • Dimension (L*W*H) tester : 320×210×550 mm (3 stations)
  • Weight for stations : 10 kg (3 stations)
Lasting adhesive tester TLAT-A11
  • Standard roller : 2000 ± 50 g
  • Testing stations : 6
  • Dimension (L*W*H) tester : 650×210×550 mm (6 stations)
  • Weight for stations : 15 kg (6 stations)
Melt flow Indexer TMFI-A10
  • Measuring range : 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
  • Measuring rate : 0.001 S
  • Temperature range : 50 to 400°C
  • Temperature precision : ± 0.5°C
Melt flow Indexer TMFI-A11
  • Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
  • Measuring rate : 0.001 S
  • Temperature range : 50 to 400°C
  • Temperature precision : ± 0.5°C
Mooney viscometer TMV-A10
  • Control temperature range : Normal temperature to 200°C
  • Temperature display resolution : 0.01°C
  • Temperature control accuracy : ± 0.3°
  • Calibration accuracy : Mooney value ± 0.5
Mullen burst tester TP-K10
  • Measurement range : 0 to 5600 kPa
  • Accuracy : ± 0.5 % F.S.
  • Compression speed : 170 ± 15 ml/min
  • Clamp pressure : ≥ 690 kPa
Mullen burst tester TP-K11
  • Measurement range : 0 to 1600 kPa
  • Accuracy : ± 0.5 % F.S.
  • Compression speed : 95 ± 5 ml/min
  • Clamp pressure : ≥ 430 kPa
No rotor rheometer TNRR-A10
  • Temperature tester : Room temperature to 200°C
  • Temperature display resolution : 0.1°C
  • Temperature control accuracy : ≤ ± 0.3°C
  • Rotor speed : 100 times/ min
Oxygen Index Tester TOIT-A10
  • Resolution : 0.1 % O2
  • Measuring range : 0 to 100 % O2
  • Precision : ± 0.4 % O2
  • Response time : < 10 S
Paper air permeability tester TP-J10
  • Measuring range : 0 to 1000 ml/min
  • Test area : 10 ± 0.02 cm2
  • Area differential pressure : 1 ± 0.01 kPa
  • Inner diameter of grip ring : 35.68 ± 0.05 mm
Paper and cardboard thickness meter TP-E20
  • Measuring range : 0 to 4 mm
  • Accuracy : 0.01 or 0.001 mm
  • Gauge : Analogue gauge display
  • Contact pressure (to create false weight) : 100 ± 10 kPa
Paper and cardboard thickness meter TP-E21
  • Measuring range : 0 to 20 mm
  • Accuracy : 0.01 mm
  • Gauge : Analogue gauge display
  • Contact pressure (to create false weight) : 20 ± 0.5 kPa
Paper tearing tester TP-J20
  • Measuring range : 0 to 1000 mN
  • Resolution : 0.1 mN
  • Indication error : ± 1 %
  • Tearing arm : 104 ± 1 mm
Portable Vibration Calibrator LPVC-A10
  • Frequency (continually adjustable) : 10 Hz to1280 Hz + 0.01 %
  • Amplitude acceleration ( at 30m/s2 pk ) : 40 Hz to 320 Hz + 0.3 dB + 1 digit
  • Amplitude velocity ( at 25mm / sec pk ) : 40 Hz to 320 Hz + 0.5dB +1 digit
  • Amplitude displacement ( at 50 μm pk-pk ) : 40 Hz to 320 Hz + 0.5 dB + 1 digit
Primary adhesive tester TPAT-A10
  • Inclined adjustable angle : 0 to 40°
  • Panel width : 120 mm
  • Test area width : 80 mm
  • Standard steel balls : 1/32 to 1 inch
Pulp beating (refining) freeness tester TP-C10
  • Measurement range : 0 to 100° SR
  • Sealed testing speed : 100 ± 10 mm/s
  • Volume of distilled water : 1000 ± 5 ml
  • Draining time : 149 ± 1 s
Puncture strength tester TP-J12
  • Measuring range : A (1 to 6) J indicating error ± 0.05 J
    B (1 to 12) J indicating error ± 0.05 J
    C (1 to 24) J indicating error ± 0.05 J
    D (1 to 48) J indicating error ± 0.05 J
    The indicating errors w.r.t measurement range of 20 to 80 %
  • Frictional resistance : <0.25 J
  • Pyramid dimension : Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
  • Dimension : 800×470×840 mm
Rockwell hardness meter (motorized type) TRHM-B10
  • Preliminary test force : 98 N
  • Total test force : 588, 980, 1471 N
  • Brinell hardness test : 306, 613, 1839 N
  • Vickers hardness test : 294, 588, 980 N
Rockwell hardness meter TRHM-A10
  • Preliminary test force : 98 N
  • Total test force : 588, 980, 1471 N
  • Total test force dwell time : 0 to 30 S
  • Hardness indication : Analogue display
Rockwell hardness meter TRHM-A11
  • Preliminary test force : 98 N
  • Total test force : 588, 980, 1471 N
  • Total test force dwell time : 1 to 30 S
  • Hardness indication : Digital display
Rubber low temperature brittleness tester TRBT-A10
  • Temperature range : -60°C to 0°C
  • Temperature accuracy : ± 0.5°C
  • Impact speed : 2 m/s ± 0.2 m/s
  • Temperature fluctuation : <± 0.5°C
Rubber Low Temperature Brittleness Tester TRBT-A11
  • Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
  • Temperature accuracy : ± 0.3 ℃
  • Impact speed : 0℃ to -30℃ around 2.5 ℃/min
    -30℃ to -40℃ around 2.5 ℃/min
    -40℃ to -70℃ around 2.0 ℃/min
  • Max dimension L × W × H : 910 × 510 × 860 mm
Rubber-weiss plasticity testing machine TRWM-A10
  • Temperature range : RT 50° to 300°
  • Temperature accuracy : ± 1°
  • Measuring range : 0.01 to 25 mm
  • Accuracy : ± 0.01 mm
Softness tester TP-H10
  • Measuring range : 10 to 1000 mN
  • Division value : 1 mN
  • Accuracy : ± 1%
  • Indicating Error : ≤ 0.5
Soil moisture meter TSMM-A10
  • Measurement range : 0 to 80 %
  • Resolution : 0.1
  • Accuracy : ± 2 % n (non-saturation condition)
  • Needle : 280 mm
Soil moisture meter TSMM-A11
  • Measurement range : 0 to 90 %
  • Resolution : 0.1 or 0.01
  • Accuracy : ± 5 % n (non-saturation condition)
  • Needle : 235 mm
Soil moisture meter TSMM-A12
  • Measurement range : 0 to 60 %
  • Resolution : 0.1
  • Accuracy : ± 5 % n (non-saturation condition)
  • Needle : 280 mm
Soil nutrient tester TSNA-A10
  • Measuring range : 0.001 to 9999
  • Stability : A (absorbency of light) <0.003 within 3 mins
  • Linearity error : <3.0 %
  • Repeatability error : A (absorbency of light) <0.005
Soil nutrient tester TSNA-A11
  • Measuring range : 0.001 to 9999
  • Stability : A (absorbency of light) <0.003 within 3 mins
  • Linearity error : <3.0 %
  • Repeatability error : A (absorbency of light) <0.005
Soil Salinity tester TSST-A10
  • Salinity Measurement range : 0.00 to 19.99 ms/cm
  • Measuring accuracy : EC ± 2% full scale
  • Temperature Measurement range : -5 to 50°C
  • Temperature accuracy : ± 0.5°C
Soil water hardness meter TSHM-A10
  • Maximum load : 100 kg ( kg and N can be switched automatically)
  • Resolution : 0.01 g
  • Accuracy : ± 0.5 %
  • Measuring depth : 0 to 40 mm
Soil water hardness meter TSHM-A11
  • Maximum load : 100 kg ( kg and N can be switched automatically)
  • Resolution : 0.01 g
  • Accuracy : ± 0.5 %
  • Measuring depth : 0 to 450 mm
Soil Water potential tester TSWT-A10
  • Measuring range : 0 to 100 kPa
  • Resolution : 0.01 kPa
  • Accuracy : ± 1 kPa
  • Soil temperature measuring range : -55 to 105°C
Standard strip cutter TP-G10
  • Sample width : 15 mm
  • Sample maximum length : 300 mm
  • Parallelism : ≤ 0.1 mm
  • Dimension : 240×520×70 mm
Tensile Stiffness Tester TP-B10
  • Sample (size) length : 38×70 mm
  • Measuring range : (1-500) mN.m (divided into 7 small ranges)
  • Indication error : 0.02
  • Test speed : (200° ± 20°)/ min
Three roll mill machine TRMM-A10
  • Mixed capacity : 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
  • Temperature range : RT to 300°C
  • Temperature control system : PID control
  • Display : LED display
Vacuum Leak Tester TVLT-A10
  • Vacuum degree : 0 to 90 KPa
  • Accuracy : 1 % FS
  • Resolution : 0.1 KPa
  • Vacuum chamber effective size : 270 × 210 mm
Vertical tensile tester TP-B20
  • Sample (size) length : 0 to 200 mm adjustable
  • Sample width : 15 mm
  • Measuring range : 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
  • Accuracy : ± 1 %
Vicat softening temperature & HDT machine TVHT-A10
  • Operating temperature : Ambient temperature to 300°C
  • Heating rate : 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
  • Maximum temp. error with heating speed : ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
  • Range of deformation : 0 to 10 mm
Water absorption tester TP-C20
  • Measurement range : 0 to 200 mm
  • Specimen size : 15×250 mm
  • Division value : 1 mm
  • Number of specimen holders : 5
Water absorption tester- Cobb Tester TP-C21
  • Metal Cylinder inner area : (100 ± 0.2) cm2
  • Metal Cylinder height : 50 mm
  • Metal roller width : (200 ± 0..5) mm
  • Metal roller weight : (10 ± 0.5) kg
Whiteness and chromaticity tester TP-A10
  • Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
  • Measurement mode : Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
  • Stability : ≤ 0.1 within 30 min
  • Accuracy : Chromaticity co-ordinate 0.0001
Whiteness meter TP-A11
  • Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
  • System : D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
  • Light source : D65 as illuminating source
  • Zero drift : ≤ 0.1 %