Biosafety Cabinet Class II A2 LBS2-A20

Biosafety Cabinet Class II A2 LBS2-A20 offers maximum opening of 420 mm (17 inch) and tested opening of safety height 200 mm (8 inch). Designed with UV life indicator and ULPA Filter, Two in number, 99.999 % efficiency at 0.12 um. Built in with foot switch to avoid airflow turbulence caused by arm movement, motorized front window of two layered laminated toughened glass and anti UV, UV lamp for most efficient decontamination and remote control with all functions for easier and convenient operation. Features airflow system of 30 % air exhaust and 70 % air recirculation and three protection such as sample, environment and operator. Incorporated with interlock function for blower and front window, UV lamp and front window, UV lamp and blower and LED lamp.

Buy Now View Catalog
Tested Opening Safety height of 200 mm (8 inch)
Maximum Opening 420 mm (17 inch)
Inflow Velocity 0.53 ± 0.025 m/s
Down Flow Velocity 0.33 ± 0.025 m/s
ULPA Filter Two, 99.999 % efficient at 0.12 um, filter life indicator
Front Window Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV
Noise EN12469 ≤ 58 dB / NSF49 ≤ 61 dB
UV Lamp 30 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination
Illuminating Lamp 12 W×2 LED Lamp
Illumination ≥ 1000 Lux
Consumption 760 W
Waterproof Sockets Two, total load of two sockets: 500 W
Display LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc.
Control System Microprocessor
Airflow System 70 % air recirculation, 30 % air exhaust
Visual and audio alarm Filter replacement, front window at unsafe height, abnormal airflow velocity
Material Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-vvbacteria powder coating
Work Surface Height 750 mm
Caster Foot master caster
Power Supply AC 220 V ± 10 %, 50/60 hz; 110 V ± 10 %, 60 hz
Internal Size (W×D×H) 940×600×660 mm
External Size (W×D×H) 1100×750×2250 mm
Package Size (W×D×H) 1220×1000×1840 mm
Gross Weight 243 kg
  • Managed and monitored by an integrated microprocessor controller
    Large LCD digital display for ease of monitoring all safety parameters
    Incorporated with memory function in case of power-failure
    Work zone made up of 304 stainless steel
    Built in with time reserve function, automatic air speed adjustable with filter block and interlock function
    Integrated with visual and audible alarm for abnormal airflow velocity, filter replacement, front window at unsafe height
    Designed with universal caster with brake and leveling feet
    Easy to use, operate and maintain
    Easy to clean, corrosion resistant, stainless steel lining
    Incorporated with air vent
Sr. No Name of the Accessory Unit
1.       Illumination LED Lamp 2
2.       UV Lamp 1
3.       Base Stand 1
4.       Remote Control 1
5.       Foot Switch 1
6.       Drain Valve 1
7.       Waterproof Sockets 2
Electric Height Adjustable Base Stand

Biosafety Cabinet Class II A2 is widely used in pathology, research laboratories, universities, colleges and hospitals. It is suitable to use for microbiology research in absence of volatile, toxic chemicals and radionuclide.

{"Tested Opening":"Safety height of 200 mm (8 inch)","Maximum Opening":"420 mm (17 inch)","Inflow Velocity":"0.53 \u00b1 0.025 m\/s","Down Flow Velocity":"0.33 \u00b1 0.025 m\/s","ULPA Filter":"Two, 99.999 % efficient at 0.12 um, filter life indicator","Front Window":"Motorized, two-layer laminated toughened glass \u2265 5 mm, anti UV","Noise":"EN12469 \u2264 58 dB \/ NSF49 \u2264 61\u00a0dB","UV Lamp":"30 W\u00d71 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination","Illuminating Lamp":"12 W\u00d72 LED Lamp","Illumination":"\u2265 1000 Lux","Consumption":"760 W","Waterproof Sockets":"Two, total load of two sockets: 500 W","Display":"LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc.","Control System":"Microprocessor","Airflow System":"70 % air recirculation, 30 % air exhaust","Visual and audio alarm":"Filter replacement, front window at unsafe height, abnormal airflow velocity","Material":"Work Zone: 304 stainless steel;\nMain Body: Cold-rolled steel with anti-vvbacteria powder coating","Work Surface Height":"750 mm","Caster":"Foot master caster","Power Supply":"AC 220 V \u00b1 10 %, 50\/60 hz; 110 V \u00b1 10 %, 60 hz","Internal Size (W\u00d7D\u00d7H)":"940\u00d7600\u00d7660\u00a0mm","External Size (W\u00d7D\u00d7H)":"1100\u00d7750\u00d72250 mm","Package Size (W\u00d7D\u00d7H)":"1220\u00d71000\u00d71840 mm","Gross Weight":"243 kg"}
Managed and monitored by an integrated microprocessor controller
Large LCD digital display for ease of monitoring all safety parameters
Incorporated with memory function in case of power-failure
Work zone made up of 304 stainless steel
Built in with time reserve function, automatic air speed adjustable with filter block and interlock function
Integrated with visual and audible alarm for abnormal airflow velocity, filter replacement, front window at unsafe height
Designed with universal caster with brake and leveling feet
Easy to use, operate and maintain
Easy to clean, corrosion resistant, stainless steel lining
Incorporated with air vent
Biosafety Cabinet Class II A2 is widely used in pathology, research laboratories, universities, colleges and hospitals. It is suitable to use for microbiology research in absence of volatile, toxic chemicals and radionuclide.


Related Products of Class II Biosafety Cabinet

Labtron offers highly efficient and advanced technology based Class II, Type A2 Biological Safety Cabinets which provides protection to product, personnel and environment against airborne biological or particulate chemical agents. our class II biosafety cabinet storage ensures no leakage and free air return mode in the front suction channel. These products are certified by NSF/ANSI49 and are safe for the users.

Biosafety Cabinet Class II A2 LBS2-A21

Biosafety Cabinet Class II A2 LBS2-A21

Tested Opening : Safety height of 200 mm (8 inch)

Maximum Opening : 420 mm (17 inch)

Inflow Velocity : 0.53 ± 0.025 m/s

Biosafety Cabinet Class II A2 NSF Certified LBS2-A31

Biosafety Cabinet Class II A2 NSF Certified LBS2-A31

External Dimension (W×D×H) : 1087×775×2265 mm

 Internal Dimension (W×D×H) : 910×600×660 mm

 Work Surface Height : 750 mm

Biosafety Cabinet Class II A2 LBS2-A23
Biosafety Cabinet Class II A2 LBS2-A23

Tested Opening : Safety height of 200 mm (8 inch)

Maximum Opening : 550 mm (22 inch)

Inflow Velocity : 0.53 ± 0.025 m/s

Biosafety Cabinet Class II A2 NSF Certified LBS2-A30
Biosafety Cabinet Class II A2 NSF Certified LBS2-A30

External Dimension (W×D×H) : 1383×775×2295 mm

 Internal Dimension (W×D×H) : 1210×600×660 mm

 Work Surface Height : 750 mm

Biosafety Cabinet Class II B2 LBS2-B20

Biosafety Cabinet Class II B2 LBS2-B20

Max Opening : 420 mm (17 inch)

Tested Opening : Safety Height 200 mm(8 inch)

Inflow Velocity : 0.53 ± 0.025 m/s

Biosafety Cabinet Class II B2 LBS2-B21

Biosafety Cabinet Class II B2 LBS2-B21

Max Opening : 420 mm (17 inch)

Tested Opening : Safety Height 200 mm(8 inch)

Inflow Velocity : 0.53 ± 0.025 m/s

Biosafety Cabinet Class II A2 LBS2-A24
Biosafety Cabinet Class II A2 LBS2-A24

Tested Opening : Safety height of 200 mm (8 inch)

Maximum Opening : 370 mm (15 inch)

Inflow Velocity : 0.53 ± 0.025 m/s

Biosafety Cabinet Class II A2 LBS2-A22
Biosafety Cabinet Class II A2 LBS2-A22

Tested Opening : Safety height of 200 mm (8 inch)

Maximum Opening : 500 mm (20 inch)

Inflow Velocity : 0.53 ± 0.025 m/s

Clean Benches

Horizontal laminar flow clean bench LHCB-A11

External dimension (W x L x H) 1340 x 800 x 1800 mm
Internal dimension (W x L x H) 1180 x 620 x 575 mm
Illumination ≥ 300 lux

Horizontal laminar flow clean bench LHCB-A10

External dimension (W x L x H) 1590 x 800 x 1800 mm
Internal dimension (W x L x H) 1430 x 620 x 575 mm
Illumination ≥ 300 lux

Vertical Laminar Flow Cabinets

Our Vertical Laminar Flow Cabinet provides high degree of contamination free environment. It features tempered glass window for better observation and also provides protection from UV rays. It is widely used in medical, pharmaceutical, electronic and industrial sectors.

Vertical Laminar Flow Cabinet LVAC-A11
External dimension 802 × 650 × 1550 mm
Internal dimension 800 × 530 × 540 mm
Work surface height 660 mm
Vertical Laminar Flow Cabinet LVAC-A10
External dimension 680 × 410 × 1160 mm
Internal dimension 630 × 375 × 615 mm
Work surface height NA

Horizontal Laminar Flow Cabinets

Horizontal Laminar Flow Cabinet LHAC-A11

External dimension 1800 × 820 × 2070 mm
Internal dimension 1700 × 500 × 570 mm
Work surface height 750 mm

Horizontal Laminar Flow Cabinet LHAC-A10

External dimension 1300 × 820 × 2040 mm
Internal dimension 1200 × 500 × 570 mm
Work surface height 750 mm

PCR Cabinet

PCR Cabinet LPCR-A10
Internal dimension ( W x D x H ) 900 x 595 x 560 mm
External dimension ( W x D x H ) 1000 x 705 x 1770 mm
UV lamp 20 W x 2
PCR Cabinet LPCR-A11
Internal dimension ( W x D x H ) 700 x 595 x 550 mm
External dimension ( W x D x H ) 800 x 700 x 1770 mm
UV lamp 20 W x 1

Cytotoxic Safety Cabinet

Cytotoxic Safety Cabinet LCSC-A10

Exhaust Volume 465 m3/h (273 cfm)
Tested Opening Safety Height 200 mm (8 inches)
Max Opening 440 mm (17 inches)

Cytotoxic Safety Cabinet LCSC-A11

Exhaust Volume 347 m3/h (204 cfm)
Tested Opening Safety Height 200 mm (8 inches)
Max Opening 440 mm (17 inches)

Talk to us?