Oven |
- Maximum capacity: 22 L
- Temperature range: RT + 5 ℃ to 400 ℃
- Temperature accuracy: ± 0.1 ℃
- Temperature program: 9-phase/ 10 platform
- Program total time: 9999.9 min
- Maximum temperature heating rate: 0.1 to 60 ℃/ min
- Maximum cooling rate: ˂ 10 mins (250 to 50 ℃)
|
Sample injector |
- Temperature range: RT+ 7 ℃ to 420 ℃
- Temperature control: Automatic
- Injector type: Column or split
- Maximum sample inlet: 3 pcs
- Carrier gas flow type: Constant pressure
- Pre column pressure range: 0 to 400 kPa
- Pre column pressure accuracy: 0.1 kPa
- Mobile phase flow range: H2: 0 to 200 ml/min, N2: 0 to 150 ml/min
|
Detector |
- Temperature range: RT + 7 ℃ to 420 ℃
- Maximum installation: Dual detector
- Flame ignition mode: Automatic
- Flame Ionization Detector (FID): Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s
(Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10 -13 A
Dynamic range: 10 7
RSD: ≤ 3 % |
Power supply |
AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W |
Packing dimension |
1020 × 660 × 740 mm |
Gross Weight |
82 kg |
Net weight |
70 kg |
-
7-inch LCD display specifies temperature, gas flow and heating curve
H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
Equipped with capillary analysis system and capillary split sampler
Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
Standard unit for high-speed analysis with polar capillary column
PEG-20M and FFAP stationary phase polar capillary columns can be coupled
Dual FID detector with automatic flame ignition and baseline signal display
Self-diagnostic and automatic fault recognition function
Multi-core and 32-bit embedded hardware system ensures the reliable operation
Equipped with chromatography workstation software to process data
Memory function can store 20 sample test data
RS232 interface and LAN port
Accessories no |
Accessories name |
1. |
FID detector system |
2. |
Capillary injection system |
3. |
Chromatography workstation software |
Accessories no |
Accessories name |
1 |
Polar capillary columns PEG-20M
Stationary phase: 30 m × 0.32 mm
injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
|
2 |
Polar capillary columns FFAP
Stationary phase: 30 m × 0.32 mm
Injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
|
3 |
Syringe 1 ul |
4 |
Syringe 5 ul |
Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.
{"Oven":{"Maximum capacity":"22 L","Temperature range":"RT + 5 \u2103 to 400 \u2103","Temperature accuracy":"\u00b1 0.1 \u2103","Temperature program":"9-phase\/ 10 platform","Program total time":"9999.9 min","Maximum temperature heating rate":"0.1 to 60 \u2103\/ min","Maximum cooling rate":"\u02c2 10 mins (250 to 50 \u2103)"},"Sample injector":{"Temperature range":"RT+ 7 \u2103 to 420 \u2103","Temperature control":"Automatic","Injector type":"Column or split","Maximum sample inlet":"3 pcs","Carrier gas flow type":"Constant pressure","Pre column pressure range":"0 to 400 kPa","Pre column pressure accuracy":"0.1 kPa","Mobile phase flow range":"H2: 0 to 200 ml\/min, N2: 0 to 150 ml\/min"},"Detector":{"Temperature range":"RT + 7 \u2103 to 420 \u2103","Maximum installation":"Dual detector","Flame ignition mode":"Automatic","Flame Ionization Detector (FID)":"Logarithmic amplifier
\nHigh voltage switch control
\nBaseline signal display
\nIgnition coil control
\nDetection limit: \u22643 \u00d710 to 12 g\/s \n(Sample: n-hexadecane)
\nBaseline noise: \u2264 5 \u00d7 10 - 14 <\/sup> A
\nBaseline draft: \u2264 6 \u00d7 10 -13 <\/sup> A
\nDynamic range: 10 7 <\/sup>
\nRSD: \u2264 3 %"},"Power supply":"AC 220 V \u00b1 22 V, 50 Hz \u00b1 0.5 Hz, 3000 W","Packing dimension":"1020 \u00d7 660 \u00d7 740 mm","Gross Weight":"82 kg","Net weight":"70 kg"}
7-inch LCD display specifies temperature, gas flow and heating curve
H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
Equipped with capillary analysis system and capillary split sampler
Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
Standard unit for high-speed analysis with polar capillary column
PEG-20M and FFAP stationary phase polar capillary columns can be coupled
Dual FID detector with automatic flame ignition and baseline signal display
Self-diagnostic and automatic fault recognition function
Multi-core and 32-bit embedded hardware system ensures the reliable operation
Equipped with chromatography workstation software to process data
Memory function can store 20 sample test data
RS232 interface and LAN port
Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.