Ion Chromatograph LPIC-A10

Ion Chromatograph LPIC-A10 is a light weight, portable design model with powerful data processing system. The quick ion chromatograph columns are used for rapid 5 min detection. Adopted with built –in multi-channel solvent selection valve helps in gradient elusion, it shortens peak time, and improves efficiency of the chromatograph conducted. Upgraded with dual detection system (dual column for various applications), supports the needs of different industries.

Buy Now View Catalog
Chromatographic Pump
  • Type: High-pressure and low –pulse double plunger tandem advection pump
  • Maximum Pressure: 35 MPa (PEEK)
  • Flow Range: 0.001 to 9.999 mL/min
  • Flow accuracy: ± 0.5 %
  • Flow Repeatability: RSD ≤ 0.1%
  • Flow stability: (0.2 to 0.5) mL/min, ≤ 3 %
    (0.5 to 1.0) mL/min, ≤ 2 %
    >1.0 mL/min, ≤ 2 %
Built-in Heat conduction type column heater
  • Temperature range: Room temperature +5°C to 60°C (41 to 140°F)
  • Allowable deviation: ± 1°C
  • Temperature stability: ≤ 0.5°C/h
Electromagnetic injection valve
  • Maximum pressure: 35 MPa
  • Control mode: By stepper motor
  • Power supply: 24 V (DC)
Digital and temperature control detection system
  • Type: Temperature control and bipolar conductivity detector
  • Detection type: Bipolar conductivity detection
  • Cell volume: ≤ 0.8 µL
  • Measurement range: 0 to 45000 µ S/cm (adjustable)
  • Detection resolution: ≤ 0.0020 nS/cm
  • Output voltage: -6000 to 6000 mV (adjustable)
  • Temperature range: Room temperature +5°C to 60°C (41 to 140°F)
  • Temperature accuracy: ± 0.01°C
  • Maximum pressure: 10 MPa
  • Baseline drift: ≤ 20 % FS/30 min
  • Baseline noise: ≤0.5 % FS
  • Instrument linearity: ≥ 0.999
  • Quantitative Repeatability: ≤0.5 %
  • Qualitative Repeatability: ≤2 %
  • Minimum detectable concentration: Cl-≤0.005 µg/mL
    Li+ ≤0.005 µg/mL
Flow system
  • Plastic path flow: Made of PEEK material
  • Six way valve: PEEK material pressure 5000 psi, independent automatic collecting and flow function
Panel computer
  • Display screen: 12.3 inch
  • Internal memory: 2G
  • Weight: 786 g
External size (L × W × H) 440 × 226 × 420 mm
Net weight 8 kg
Gross weight 11 kg
  • Built-in column temperature control box for accurate experimental results
    Capable with Flash column for rapid detection of anions and cations
    Intelligent flow path clearing system for easy cleaning
    Real time display
    Wi-Fi connection for convenient data transfer
    Continuous, non-stop 10 hours working system
    Easy to operate
Accessories No. Name Qty.
1 Ion Chromatography Host 1
2 High Pressure Advection Pump 1
3 Conductivity Detector 1
4 Anion Column 1
5 Anion Guard Column 1
6 Suppressors 1
7 Chromatography Workstation 1
8 Column Thermostat System 1
9 Spare Parts Kits 1
10 Vacuum Degassing Pump 1
11 Sand Core Filtration Devices 1
12 Pretreatment Column 20
13 0.22 µm syringe filter 200
Accessories No. Name Qty.
1 Anion Column 1
2 Guard Column 1
3 Anion Suppressor 1
4 Spare Parts Kit 1

Used for on field selective analysis of organic and inorganic ions, also used in quality and research laboratories across pharmaceutical, water quality, chemical industries.

{"Chromatographic Pump":{"Type":"High-pressure and low \u2013pulse double plunger tandem advection pump","Maximum Pressure":"35 MPa (PEEK)","Flow Range":"0.001 to 9.999 mL\/min","Flow accuracy":"\u00b1 0.5 %","Flow Repeatability":"RSD \u2264 0.1%","Flow stability":"(0.2 to 0.5) mL\/min, \u2264 3 %\n(0.5 to 1.0) mL\/min, \u2264 2 %\n>1.0 mL\/min, \u2264 2 %"},"Built-in Heat conduction type column heater":{"Temperature range":"Room temperature +5\u00b0C to 60\u00b0C (41 to 140\u00b0F)","Allowable deviation":"\u00b1 1\u00b0C","Temperature stability":"\u2264 0.5\u00b0C\/h"},"Electromagnetic injection valve":{"Maximum pressure":"35 MPa","Control mode":"By stepper motor","Power supply":"24 V (DC)"},"Digital and temperature control detection system":{"Type":"Temperature control and bipolar conductivity detector","Detection type":"Bipolar conductivity detection","Cell volume":"\u2264 0.8 \u00b5L","Measurement range":"0 to 45000 \u00b5 S\/cm (adjustable)","Detection resolution":"\u2264 0.0020 nS\/cm","Output voltage":"-6000 to 6000 mV (adjustable)","Temperature range":"Room temperature +5\u00b0C to 60\u00b0C (41 to 140\u00b0F)","Temperature accuracy":"\u00b1 0.01\u00b0C","Maximum pressure":"10 MPa","Baseline drift":"\u2264 20 % FS\/30 min","Baseline noise":"\u22640.5 % FS","Instrument linearity":"\u2265 0.999","Quantitative Repeatability":"\u22640.5 %","Qualitative Repeatability":"\u22642 %","Minimum detectable concentration":"Cl-\u22640.005 \u00b5g\/mL\nLi+ \u22640.005 \u00b5g\/mL"},"Flow system":{"Plastic path flow":"Made of PEEK material","Six way valve":"PEEK material pressure 5000 psi, independent automatic collecting and flow function"},"Panel computer":{"Display screen":"12.3 inch","Internal memory":"2G","Weight":"786 g"},"External size (L \u00d7 W \u00d7 H)":"440 \u00d7 226 \u00d7 420 mm","Net weight":"8 kg","Gross weight":"11 kg"}
Built-in column temperature control box for accurate experimental results
Capable with Flash column for rapid detection of anions and cations
Intelligent flow path clearing system for easy cleaning
Real time display
Wi-Fi connection for convenient data transfer
Continuous, non-stop 10 hours working system
Easy to operate
Used for on field selective analysis of organic and inorganic ions, also used in quality and research laboratories across pharmaceutical, water quality, chemical industries.


Ion Chromatography

Ion chromatograph system LICS-A22

Ion Chromatographic pump
Type High pressure and low pulse double plunger tandem advection pump
Maximum pressure 35 MPa (PEEK)
Display pressure accuracy ≤ 0.1 MPa
Flow stability (0.2 to 0.5) ml/ min ≤ 3 % , (0.5 to 1.0) ml/ min ≤ 2 %, > 1.0 ml/ min ≤ 2 %
Flow range 0.001 to 9.999 ml/ min
Pressure pulse ≤ 0.5 %
Numerical control and electromagnetic injection
Maximum pressure 35 MPa
Contact material of the rotor PEEK
Control mode By Stepper motor
Power supply DC 24 V
Column heater
Operating temperature range Room temperature 20 to 60°C ( 68 to 140°F)
Controlling temperature accuracy ± 0.01°C
Allowable deviation of column heater temperature ± 2°C
Temperature stability ≤ 1°C/ h

Ion chromatograph system LICS-A20

Ion Chromatographic Pump
Type High pressure and low pulse double plunger tandem advection pump
Maximum pressure 35 MPa (PEEK)
Pressure display accuracy ≤ 0.1 MPa
Flow stability (0.2 to 0.5) ml/ min ≤ 3 %
(0.5 to 1.0) ml/ min ≤ 2 %
> 1.0 ml/ min 2 %
Flow range 0.001 to 9.999 ml/ min
Pressure pulse ≤ 0.5%
Conductivity detector
Type Temperature Control and Bipolar Conductivity Detector
Detection mode Bipolar conductivity detection
Cell volume ≤ 0.8 µL
Detection range 0 to 35000 µS/ cm
Detection resolution ≤ 0.0020 nS/ cm
Output voltage - 6000 to +6000 mV (adjustable)
Baseline noise ≤ 0.05 % F.S.
Baseline drift ≤ 3 % FS/ 30 min
Operating temperature range Room temperature +5 to 60°C (41 to 140°F)
Controlling temperature accuracy ± 0.01°C
Maximum pressure 10 MPa
Linear range ≥ 103
Instruments linearity ≥ 0.999
Quantitative repeatability ≤ 1.0 %
Qualitative repeatability ≤ 1.0 %
Minimum detectable concentration Cl ≤ 0.0005 ug/ ml
BrO3 ≤ 0.001 ug/ ml
Li+ ≤ 0.001 ug/ ml
Flow system
Plastic flow path Made of PEEK materials
Six way Valve PEEK material, 5000 psi pressure, independent automatic collection and flow function

Gas Chromatography

Gas Chromatography LGC-B11
Oven
Maximum capacity 22 L
Temperature range RT + 5 ℃ to 400 ℃
Temperature accuracy ± 0.1 ℃
Temperature program 9-phase/ 10 platform
Program total time 9999.9 min
Maximum temperature heating rate 0.1 to 60 ℃/ min
Maximum cooling rate ˂ 10 mins (250 to 50 ℃)
Sample injector
Temperature range RT+ 7 ℃ to 420 ℃
Temperature control Automatic
Injector type Column or split
Maximum sample inlet 3 pcs
Carrier gas flow type Constant pressure
Pre column pressure range 0 to 400 kPa
Pre column pressure accuracy 0.1 kPa
Mobile phase flow range H2: 0 to 200 ml/min, N2: 0 to 150 ml/min
Detector
Temperature range RT + 7 ℃ to 420 ℃
Maximum installation Dual detector
Flame ignition mode Automatic
Flame Ionization Detector (FID) Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10 -13 A
Dynamic range: 10 7
RSD: ≤ 3 %

GC-MS

Gas chromatography mass spectrometry GC-MS-879
Gas Chromatography Specifications
Model No GC-87
Flow rate 1 ~ 1.5 ml / min
Maximum flow rate 10 ml / min
Inlet temperature 450 °C
Pressure range 0 ~ 100 psi
Heating rate Upto 120 °C / min
Room temperature 4 °C ~ 450 °C
Pressure control mode Electronic pressure control ( Supports CV and CC )
Split mode Split / split less
Split ratio 1000 : 1
Temperature programming 7 stages / 8 platforms
Auto sampler Optional
Mass Spectrometry Specifications
Model No MS-89
Mass range 1.5 ~ 1000 amu
Ion – source temperature 100 °C ~ 350 °C
GC-MS interface temperature 450 °C
Scan rate Upto 10000 amu/s
Stability ± 0.10 amu / 48 hrs.
Filament emission current 0 ~ 350 µA
EI source ionization energy 5 eV ~ 250 eV
Resolution Unit resolution
Detector High energy dynode electron multiplier
Sensitivity Full scan ( S / N is ≥ 30 : 1 )
Vacuum Turbo molecular pump ( 67 L/s )