Chromatographic Pump |
- Type: High-pressure and low –pulse double plunger tandem advection pump
- Maximum Pressure: 35 MPa (PEEK)
- Flow Range: 0.001 to 9.999 mL/min
- Flow accuracy: ± 0.5 %
- Flow Repeatability: RSD ≤ 0.1%
- Flow stability: (0.2 to 0.5) mL/min, ≤ 3 %
(0.5 to 1.0) mL/min, ≤ 2 %
>1.0 mL/min, ≤ 2 % |
Built-in Heat conduction type column heater |
- Temperature range: Room temperature +5°C to 60°C (41 to 140°F)
- Allowable deviation: ± 1°C
- Temperature stability: ≤ 0.5°C/h
|
Electromagnetic injection valve |
- Maximum pressure: 35 MPa
- Control mode: By stepper motor
- Power supply: 24 V (DC)
|
Digital and temperature control detection system |
- Type: Temperature control and bipolar conductivity detector
- Detection type: Bipolar conductivity detection
- Cell volume: ≤ 0.8 µL
- Measurement range: 0 to 45000 µ S/cm (adjustable)
- Detection resolution: ≤ 0.0020 nS/cm
- Output voltage: -6000 to 6000 mV (adjustable)
- Temperature range: Room temperature +5°C to 60°C (41 to 140°F)
- Temperature accuracy: ± 0.01°C
- Maximum pressure: 10 MPa
- Baseline drift: ≤ 20 % FS/30 min
- Baseline noise: ≤0.5 % FS
- Instrument linearity: ≥ 0.999
- Quantitative Repeatability: ≤0.5 %
- Qualitative Repeatability: ≤2 %
- Minimum detectable concentration: Cl-≤0.005 µg/mL
Li+ ≤0.005 µg/mL |
Flow system |
- Plastic path flow: Made of PEEK material
- Six way valve: PEEK material pressure 5000 psi, independent automatic collecting and flow function
|
Panel computer |
- Display screen: 12.3 inch
- Internal memory: 2G
- Weight: 786 g
|
External size (L × W × H) |
440 × 226 × 420 mm |
Net weight |
8 kg |
Gross weight |
11 kg |
-
Built-in column temperature control box for accurate experimental results
Capable with Flash column for rapid detection of anions and cations
Intelligent flow path clearing system for easy cleaning
Real time display
Wi-Fi connection for convenient data transfer
Continuous, non-stop 10 hours working system
Easy to operate
Accessories No. |
Name |
Qty. |
1 |
Ion Chromatography Host |
1 |
2 |
High Pressure Advection Pump |
1 |
3 |
Conductivity Detector |
1 |
4 |
Anion Column |
1 |
5 |
Anion Guard Column |
1 |
6 |
Suppressors |
1 |
7 |
Chromatography Workstation |
1 |
8 |
Column Thermostat System |
1 |
9 |
Spare Parts Kits |
1 |
10 |
Vacuum Degassing Pump |
1 |
11 |
Sand Core Filtration Devices |
1 |
12 |
Pretreatment Column |
20 |
13 |
0.22 µm syringe filter |
200 |
Accessories No. |
Name |
Qty. |
1 |
Anion Column |
1 |
2 |
Guard Column |
1 |
3 |
Anion Suppressor |
1 |
4 |
Spare Parts Kit |
1 |
Used for on field selective analysis of organic and inorganic ions, also used in quality and research laboratories across pharmaceutical, water quality, chemical industries.
{"Chromatographic Pump":{"Type":"High-pressure and low \u2013pulse double plunger tandem advection pump","Maximum Pressure":"35 MPa (PEEK)","Flow Range":"0.001 to 9.999 mL\/min","Flow accuracy":"\u00b1 0.5 %","Flow Repeatability":"RSD \u2264 0.1%","Flow stability":"(0.2 to 0.5) mL\/min, \u2264 3 %
\n(0.5 to 1.0) mL\/min, \u2264 2 %
\n>1.0 mL\/min, \u2264 2 %"},"Built-in Heat conduction type column heater":{"Temperature range":"Room temperature +5\u00b0C to 60\u00b0C (41 to 140\u00b0F)","Allowable deviation":"\u00b1 1\u00b0C","Temperature stability":"\u2264 0.5\u00b0C\/h"},"Electromagnetic injection valve":{"Maximum pressure":"35 MPa","Control mode":"By stepper motor","Power supply":"24 V (DC)"},"Digital and temperature control detection system":{"Type":"Temperature control and bipolar conductivity detector","Detection type":"Bipolar conductivity detection","Cell volume":"\u2264 0.8 \u00b5L","Measurement range":"0 to 45000 \u00b5 S\/cm (adjustable)","Detection resolution":"\u2264 0.0020 nS\/cm","Output voltage":"-6000 to 6000 mV (adjustable)","Temperature range":"Room temperature +5\u00b0C to 60\u00b0C (41 to 140\u00b0F)","Temperature accuracy":"\u00b1 0.01\u00b0C","Maximum pressure":"10 MPa","Baseline drift":"\u2264 20 % FS\/30 min","Baseline noise":"\u22640.5 % FS","Instrument linearity":"\u2265 0.999","Quantitative Repeatability":"\u22640.5 %","Qualitative Repeatability":"\u22642 %","Minimum detectable concentration":"Cl-\u22640.005 \u00b5g\/mL
\nLi+ \u22640.005 \u00b5g\/mL"},"Flow system":{"Plastic path flow":"Made of PEEK material","Six way valve":"PEEK material pressure 5000 psi, independent automatic collecting and flow function"},"Panel computer":{"Display screen":"12.3 inch","Internal memory":"2G","Weight":"786 g"},"External size (L \u00d7 W \u00d7 H)":"440 \u00d7 226 \u00d7 420 mm","Net weight":"8 kg","Gross weight":"11 kg"}
Built-in column temperature control box for accurate experimental results
Capable with Flash column for rapid detection of anions and cations
Intelligent flow path clearing system for easy cleaning
Real time display
Wi-Fi connection for convenient data transfer
Continuous, non-stop 10 hours working system
Easy to operate
Used for on field selective analysis of organic and inorganic ions, also used in quality and research laboratories across pharmaceutical, water quality, chemical industries.