Ash Content Tester LACT-A10

Ash Content Tester LACT-A10 is the device composed of muffle furnace, temperature controller and electric heating plate. It is small size and needs less land with special fire-resistant material and heating components. The heating time is short and it has a long lifetime. It used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and petroleum products.

Buy Now View Catalog
Electric Muffle Furnace
  • Controlled temperature: 775 ±25 ℃
  • Temperature rising time of empty chamber: ≤ 50 min
  • Furnace temperature uniformity: ≤ 15℃
  • Internal dimension: 200 × 120 × 80 mm
  • External dimension: 490 × 490 × 450 mm
  • Power consumption: 2.5 kW
  • Power supply: AC 220V ±10%, 50 Hz
  • Net weight: 35 kg
Temperature controller
  • Maximum control temperature: 1200 ℃
  • Dimension: 500 × 300 × 235 mm
  • Power consumption: 5000 W
  • Power supply: AC 220±10% V, 50Hz
  • Net weight: 5 kg
Electric heating plate
  • Heating power: (1 to 6) grades, continuously adjustable
  • Temperature: 400℃
  • Diameter of heating plate: Φ 180 mm
  • Dimension: 280 × 250 × 90 mm
  • Power consumption: 2000 W
  • Power supply: AC 220±10%V, 50Hz
  • It is composed of muffle furnace, a temperature controller and electric heating plate
    Muffle furnace adopts all-in-one structure
    Equipped with special fire-resistant material and heating components
    Adjustable LED and designed with temperature controller
    The overshoot is small and temperature control is stable
    Material used cold-roll steel sheet of outer shell furnace
    Good anti-corrosion and long life time
Accessories No. Name Qty
1 Main unit 1 set
2 Temperature controller 1 set
3 Hot plate 1 set
4 Thermocouple 1 piece
5 Compensation lead wire 1 piece
6 Porcelain crucible (50ml) 10 piece
7 Porcelain crucible (100ml) 10 piece
8 Crucible tong 1 piece
9 Fuse 2 piece

Ash Content Tester is used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and residual fuels, gas turbine fuels, crude oils, lubricating oils, waxes, and other petroleum products, in which any ash-forming materials present are normally considered to be undesirable impurities or contaminants.

{"Electric Muffle Furnace":{"Controlled\u00a0temperature":"775 \u00b125 \u2103","Temperature rising time of empty chamber":"\u2264 50 min","Furnace temperature uniformity":"\u2264 15\u2103","Internal dimension":"200 \u00d7 120 \u00d7 80 mm","External dimension":"490 \u00d7 490 \u00d7 450 mm","Power consumption":"2.5 kW","Power supply":"AC 220V \u00b110%, 50 Hz","Net weight":"35 kg"},"Temperature controller":{"Maximum control temperature":"1200 \u2103","Dimension":"500 \u00d7 300 \u00d7 235 mm","Power consumption":"5000 W","Power supply":"AC 220\u00b110% V, 50Hz","Net weight":"5 kg"},"Electric heating plate":{"Heating power":"(1 to 6) grades, continuously adjustable","Temperature":"400\u2103","Diameter of heating plate":"\u03a6 180 mm","Dimension":"280 \u00d7 250 \u00d7 90 mm","Power consumption":"2000 W","Power supply":"AC 220\u00b110%V, 50Hz"}}
It is composed of muffle furnace, a temperature controller and electric heating plate
Muffle furnace adopts all-in-one structure
Equipped with special fire-resistant material and heating components
Adjustable LED and designed with temperature controller
The overshoot is small and temperature control is stable
Material used cold-roll steel sheet of outer shell furnace
Good anti-corrosion and long life time
Ash Content Tester is used to determine the ash in the range 0.001 to 0.180 mass %, from distillate and residual fuels, gas turbine fuels, crude oils, lubricating oils, waxes, and other petroleum products, in which any ash-forming materials present are normally considered to be undesirable impurities or contaminants.


Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Automatic Bomb Calorimeter LABC-A10

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Automatic Softening Point Tester

Automatic Softening Point Tester LSPT-A10
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml

Acid Number and Acidity Tester LAAT-A11

Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Aniline Test Equipment

Aniline Point Tester LAPT-A11
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Aniline Point Tester LAPT-A10
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W