Automatic Softening Point Tester LSPT-A10

Automatic softening point tester LSPT-A10 is a bench top microprocessor controlled analytical unit that determines the softening point of two samples at once. Operated via touch panel it uses ball and ring apparatus for reliable detection. Designed as per Test methods of Bitumen and Bituminous Mixture for Highway Engineering and ASTM D36 Standard test method for Softening of Bitumen (Ring-and-Ball Apparatus) it is ideal for determining the softening points of petroleum asphalts, coal pitch, liquid petroleum asphalt, etc.

Buy Now View Catalog
Measurement range 32 ℃ to 160 ℃
Ambient temperature 35 °C
Temperature resolution 0.01 ℃
Beaker volume 1000 mL
Relative humidity ≤85%
Heating power 600 W
Total power consumption ≤ 700 W
Power supply AC 220V ( -5 % ~ 10 % ), 50 Hz
  • Microprocessor controlled compact structure
    Automatic stirring, linear heating and test result detection
    High temperature resistant glass made beaker
    LCD display
    Dual sample simultaneous softening point detection
    Automatic print of test results
    Light touch panel
    Connects easily to PC
Sr. No Name Unit Quantity
1 Automatic Softening Point Tester Set 1
2 Steel ball locator Piece 2
3 Steel ball Piece 2
4 Shoulder ring Piece 2
5 Beaker Piece 1
6 Stirring bar Piece 1
7 Temperature sensor and cable Piece 1
8 W-line Piece 1
9 Fuse 6A( Ф 5 × 20 ) Piece 2
10 Software CD Piece 1
11 Printer paper Roll 1
12 Glycerin ( 1000 ml ) Bottle 2
13 Softening point thermometer( 30 ~ 180 )℃,scale mark 0.5 ℃ Piece 1
14 Bracket box Piece 1
15 Thermometer stopper (3#) Piece 1
16 Stopping ring for thermometer (1#) Piece 2

Used in asphalt manufacturing companies, highway and bridge construction companies, laboratories, universities, scientific research institutes, etc.

{"Measurement range":"32 \u2103 to 160 \u2103","Ambient temperature":"35 \u00b0C","Temperature resolution":"0.01 \u2103","Beaker volume":"1000 mL","Relative humidity":"\u226485%","Heating power":"600 W","Total power consumption":"\u2264 700 W","Power supply":"AC 220V ( -5 % ~ 10 % ), 50 Hz"}
Microprocessor controlled compact structure
Automatic stirring, linear heating and test result detection
High temperature resistant glass made beaker
LCD display
Dual sample simultaneous softening point detection
Automatic print of test results
Light touch panel
Connects easily to PC
Used in asphalt manufacturing companies, highway and bridge construction companies, laboratories, universities, scientific research institutes, etc.


Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Automatic Bomb Calorimeter LABC-A11

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Acid Number and Acidity Tester LAAT-A11
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10

Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Ash Content Tester

Ash Content Tester LACT-A10

Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Aniline Test Equipment

Aniline Point Tester LAPT-A10
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W
Aniline Point Tester LAPT-A11
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Talk to us?