Octane Number and Cetane Number Tester LOCT-A10 is benchtop unit designed to measure Motor octane number (MON) of aviation gasoline, light gasoline; Research octane number (RON) of gasoline for motor vehicles, blended gasoline, isomerised gasoline, arene gasoline, ethanol and Cetane number of automobile diesel fuel. Test results meets the standards of ASTM D2699-86 and ASTM D613 - 18a. Features like digital transmission technology, anti-jamming, accurate results after several repetitions, less sample volume, short test time, LCD display etc. makes it highly reliable. It is widely used in testing labs, petroleum industry, quality control, etc.
Buy Now View CatalogMeasuring Range For Aviation Gasoline | 86.0 to 105.0/MON |
Measuring Range For Gasoline For Motor Vehicles |
National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON |
Measuring Range For Ethanol |
E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON |
Measuring Range For Automobile Diesel Fuels |
Cetane number: 25 to 75/CN Cetane index: 20 to 80/CI |
Measuring Accuracy |
Aviation gasoline: ≤ ± 1.5/MON Gasoline for motor vehicles: ≤ ± 1.5/RON, ≤ ± 1.5/MO Automobile diesel fuels: ≤ ± 2.6/CN, ≤ ± 2.6/CI Regression sample retest: ≤ ± 0.5/RON, ≤ ± 0.5/MON Regression sample measurement: ≤ ± 1.5/RON, ≤ ± 1.5/MON Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON |
Precision (Confidence Level 95%) |
Reproducibility: ≤ ± 0.5/RON Repeatability: ≤ ± 0.2/RON |
Minimum Scale | 0.1/RON, 0.1/MON, 0.1/CI |
Response Time | 1 min |
Ambient Temperature | 10°C to 35°C |
Humidity | < 85% RH |
Test Result | LCD display, it can store and print |
Power Supply | AC (220 ± 10%) V, (50 ± 1) Hz |
It is used in petroleum and oil industry to determine MON, RON, AK index values for gasoline and Cetane number for diesel.
Measurement item : motor gasoline and diesel
measurement unit of octane is ON : 40 to 120
Permissible error of octane : ± 0.5 max
Capacity | 2.0 kVA |
Speed of voltage increase | 2 k V/ s |
Voltage inspection accuracy | 0.01 |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Electric Muffle Furnace |
|
||||||||||||||||
Temperature controller |
|
||||||||||||||||
Electric heating plate |
|
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Talk to us?