Labtron LBC-C20 is manufactured with desktop computer and test software. The instrument is designed and made as per the International Standards ASTM D5865-13 “Test Methods for Heat of Coal”, ASTM D240-17 “Test Methods for Calorific Value of Petroleum Products” and ASTM D4809-13 “Oxygen Bomb Calorimeter”.

Buy Now View Catalog
Heat capacity 14000 ~ 15000 J / K
Temperature measurement range 10 ~ 35 ℃
Temperature controlling range
Repeatability error ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb 20 MPa
Operation environment temperature 15 ~ 28 ℃
Temperature resolution 0.001 ℃
Mean value of heat capacity
Heating power
Temperature fluctuation Not more than 1 ℃ during a test
Ambient temperature Less than 85 %
Relative humidity
Endured pressure of oxygen bomb
Temperature saved
Measurement accuracy for heat value
Dimension
weight
Power supply AC 220 V ± 5 %, 50 Hz
  • Desktop computer to control whole test Record and save test data automatically Equipped with test software User-friendly and operation convenience

It is mainly used in petroleum, chemical, automobile and development industries. It is suitable for determining heat value of petroleum products (Gasoline, jet fuels, diesel oil and fuel oils), which do not contain water, coal, paraffin and other combustible substance.

{"Heat capacity":"14000 ~ 15000 J \/ K","Temperature measurement range":"10 ~ 35 \u2103","Temperature controlling range":"","Repeatability error":"\u2264 0.2 % (Grade C)","Endured pressure in oxygen bomb":"20 MPa","Operation environment temperature":"15 ~ 28 \u2103","Temperature resolution":"0.001 \u2103","Mean value of heat capacity":"","Heating power":"","Temperature fluctuation":"Not more than 1 \u2103 during a test","Ambient temperature":"Less than 85 %","Relative humidity":"","Endured pressure of oxygen bomb":"","Temperature saved":"","Measurement accuracy for heat value":"","Dimension":"","weight":"","Power supply":"AC 220 V \u00b1 5 %, 50 Hz"}
Desktop computer to control whole test Record and save test data automatically Equipped with test software User-friendly and operation convenience
It is mainly used in petroleum, chemical, automobile and development industries. It is suitable for determining heat value of petroleum products (Gasoline, jet fuels, diesel oil and fuel oils), which do not contain water, coal, paraffin and other combustible substance.


Related Products of Oxygen Bomb Calorimeter

Oxygen Bomb Calorimeter LBC-C22

Oxygen Bomb Calorimeter LBC-C22

Temperature measurement range : 10 ~ 35 ℃

Repeatability error : ≤ 0.2 % (Grade C)

Endured pressure in oxygen bomb : 20 MPa

Oxygen Bomb Calorimeter LBC-C21

Oxygen Bomb Calorimeter LBC-C21

Temperature controlling range : 10 ℃ ~ 35 ℃

Temperature resolution : 0.001 ℃

Mean value of heat capacity : 15 kJ / K

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10

Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Ash Content Tester

Ash Content Tester LACT-A10

Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Aniline Test Equipment

Aniline Point Tester LAPT-A11
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V
Aniline Point Tester LAPT-A10
Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg