Handheld C2H4 Ethylene Gas Detector LEGD-A10 is a portable device with built-in sampling pump having a flow rate of 1 L/min. It meets IP-66 standards which makes it suitable for use in harsh environmental conditions. Rapid speed of sampling, high flow rate, least detection time, compact design, plastic housing, storage space, etc. are some of the features which ensures accurate results in few minutes. It is used in chemical industry, food industry, etc.
Buy Now View CatalogSampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
Gas | Ethylene C2H4 |
Measure Range | 0 to 1000 ppm |
Resolution | 1ppm |
Precision | 3 to 10% F.S. |
Response Time | ≤ 10 s |
Repeatability | ≤ ± 1% |
Zero Shift | ≤ ± 1%(F.S./year) |
Display | LCD dot matrix display |
Temperature | -20°C to 50°C |
Humidity | 0 to 95 % RH |
Degree of Protection | IP-66 |
Alarm | Sound, light, vibration |
Recovery Time | ≤ 10 s |
Linearity Error | ≤ ± 1% |
Gas Unit | Units are switchable |
Battery |
3.6 V 2300 mAh lithium polymer rechargeable battery operate time is about 12 h continuously charging time: 4 to 6 h |
Operating Time | 100 h (pump off) |
Dimensions | 205×75×32 mm |
Weight | 300 g |
It is used to detect ethylene gas. Extensively used in brewing and fermentation industry, cold storage places, agricultural research, chemical labs, paper making industry, bio-pharmaceutical plant etc.
Sampling Method : Diffusion
Working conditions :
Temperature | -20 to 50°C |
Pressure | 0.9 to 1.1 (standard atmospheric pressure) |
Humidity | 10 to 95 % RH (no dew condensation) |
Explosion proof grade : Exia II CT3
Measurement principle : Non-dispersive infrared (NDIR)
Gas Detected : SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.)
Detection Uncertainty : <1.5 % F.S
Gas detected : NO2
Detection principle : Electrochemistry
Sampling method : Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Gas detected : Sulfur dioxide SO2
Detection principle : Electrochemistry
Sampling method : Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection.
Gas Detected : Nitrogen N2
Detection principle : Electrochemistry
Measurement Range : 0 to 100 % VOL
Gas Detected : O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3
Detection principle : Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC)
Measurement Range : O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM
Sampling method : Diffusion
Sensor type : CO2: solid electrolyte sensor, O2:electrochemical sensor
Detection range : CO2:0.04 to 5.00 % and O2:0.0 to 30.0 %
Sampling method : Diffusion
Measurement principle : Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas)
Detector gas : Flammable gases, oxygen gas, toxic and harmful gases
Measuring range | ± 500 Pa |
Repeatability | ± 0.2 % FS |
Resolution | 0.1 Pa |
Measuring range | 0 ∼ 125 Pa |
Accuracy |
0 ± 0.2 Pa (liner error) ± 1 % |
Operating temperature range | 0 °C ∼ 50 °C |
Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
Flow rate | 1 L/min |
Accuracy | 0.01 ppm |
Ozone measurement range | 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional ) |
Flow rate | 1.5 L/min |
Accuracy | 0.01 ppm or 3 % of reading |
Measurement range | 0 ppm ∼ 5 ppm |
Resolution | 0.001 ppm ( 0 ppm ∼ 5 ppm ) |
Temperature range | ˗ 40 °C ∼ 120 °C |
Capacity | 50 kg |
Accuracy | 1 g |
Speed | 1 s |
Temperature Measurement Range | -10℃ to 60℃ |
Temperature Resolution | 0.1°C |
Temperature Accuracy | ± 1.5℃ |
Talk to us?