Spray particle size analyzer LSPA-A10

Spray particle size analyzer LSPA-A10 is an accurate and reliable bench top spray particle size analyzer that adopts Fraunhofer of scalar diffraction principle and parallel light path design for measuring over 1 - 2000 μm particle size range. With split-type structure design, it is well equipped with high performance and high power laser, airflow protection device and stable automatic optical path alignment system.

Buy Now View Catalog
Measuring range 1 μm - 2000 μm
Principle Fraunhofer light diffraction
Spray area range 1 - 10 m
Structure Split-type
Executive standard ISO13320 - 1 : 1999
Sample type Droplet
Laser LD pump laser, 532 nm
Detector Photoelectric
Number of channel 58 pcs.
Sample introduction open
Lens protection Double air curtains
Adjusting range
  • Horizontal moving: ± 20 mm
  • Lifting: ± 20 mm
  • Rotation: ± 20°
Accuracy error < 3%
Reproducibility error < 3%
Software running Win XP/Win 7
Dimension 369 x 295 x 360 mm
  • Fraunhofer light diffraction particle size measurement principle
    High performance and high power laser
    It embraces Parallel optical testing technology and spectrum amplification technique
    Split-type structure design and adjustable test area to satisfy the needs of the spray test in any condition
    Integrated auxiliary photoelectric detector
    Unique airflow protection device to protect the lens
    Output can be in Word, Excel, Bmp picture and text format which ensures viewing and referencing of results at different situations
    Accurate and reliable

Spray particle size analyzer is used: for measurement of the droplet size produced by atomizer system, for rapid screening of formulations for the desired spray properties to improve drug delivery efficacy, for measuring the fluctuations in droplet size, for studying sprays appearing in the study of firefighting, spray granulation etc.

{"Measuring range":"1 \u03bcm - 2000 \u03bcm","Principle":"Fraunhofer light diffraction","Spray\u00a0area\u00a0range":"1 - 10 m","Structure":"Split-type","Executive standard":"ISO13320 - 1 : 1999","Sample type":"Droplet","Laser":"LD pump laser, 532 nm","Detector":"Photoelectric","Number of channel":"58 pcs.","Sample introduction":"open","Lens protection":"Double air curtains","Adjusting range":{"Horizontal moving":"\u00b1 20 mm","Lifting":"\u00b1 20 mm","Rotation":"\u00b1 20\u00b0"},"Accuracy error":"< 3%","Reproducibility error":"< 3%","Software running":"Win XP\/Win 7","Dimension":"369 x 295 x 360 mm"}
Fraunhofer light diffraction particle size measurement principle
High performance and high power laser
It embraces Parallel optical testing technology and spectrum amplification technique
Split-type structure design and adjustable test area to satisfy the needs of the spray test in any condition
Integrated auxiliary photoelectric detector
Unique airflow protection device to protect the lens
Output can be in Word, Excel, Bmp picture and text format which ensures viewing and referencing of results at different situations
Accurate and reliable
Spray particle size analyzer is used: for measurement of the droplet size produced by atomizer system, for rapid screening of formulations for the desired spray properties to improve drug delivery efficacy, for measuring the fluctuations in droplet size, for studying sprays appearing in the study of firefighting, spray granulation etc.


Laser Particle Size Analyzer

Laser Particle Size Analyzer LLPA-A10

Dispersion Type Wet
Measurement Range 0.1 to 300 µm
Channel number 39

Laser Particle Size Analyzer LLPA-A11

Dispersion Type Wet
Measurement Range 0.01 to 2000 µm
Channel number 127

Image Particle Shape & Size Analyzer

Image particle shape and size analyzer LISA-A11
Measuring range 2 μm to 6000 μm
Dispersion Ultrasonic, Stirring, Circulation
CCD High speed and resolution CCD (The shutter speed is 10-6/s)
Image particle shape and size analyzer LISA-A10
Measuring range 1μm to 6000 μm
Technology Computer image analysis technology
Particle properties measured Morphology & size

Nano Particle Size Analyzer

Nano-particle size analyzer LNPA-A10

Measuring range 1 nm-10000 nm
Principle Dynamic light scattering & Brownian motion
Test speed < 5 min

Talk to us?