Acid Number Tester LAAT-A12 is automated and controlled by microprocessor unit. It offers 0 to 1800.0 mV potential measurement range and ≥0.05 mg KOH/g acid number measurement range. It works on potentiometric titration principle. Recording the titration of the electrode potential and the titration volume, find out the equivalence point and corresponding titrant volume, and thus obtained the sample pH value. This unit can accurately detect the acid value of transformer oil, turbine oil, anti-oil, diesel, gasoline and other petroleum products. It offers Standard Determination of acid number, Determination of acid number in transformer and turbine oils in service (BTB), ASTM D664-2011).
Buy Now View CatalogGraduated flask | |
Conical flask | |
Separatory funnel | |
Volumetric analysis | |
Automatic acid titration | |
Automatic potential control | |
Measurement range | ≥0.05 mg KOH/g |
Potential measurement range | 0 to 1800.0 mV |
Burette volume | 10 mL |
Minimum titration volume | 0.001 ml |
Burette precision | ±0.1 %FS |
Precision | Fit or above the relative standards |
Ambient temperature | 5℃ to 35℃ |
Relative humidity | Less 80 % |
Temperature compensation | |
Preset adjustment range of end point | |
Preset controlling range for titration | |
Precision of titration tube | |
Test tube | |
Acidometer Full scale | |
Acidometer Accuracy | |
Heating power | |
Total power consumption | |
Power supply | AC (220±11)V , 50±1 Hz |
Dimension | About 350 × 280 ×178 mm |
Net weight | Main unit 14 kg |
Accessories no. | Name | Qty. |
---|---|---|
1 | Magnetic Agitator | 1 pcs |
2 | Agitator Strut | 1 pcs |
3 | Electrode holder | 1 pcs |
4 | Magnetic rotor | 4 pcs |
5 | RS232 serial communication line | 1 pcs |
6 | Short-circuit plug | 2 pcs |
7 | Fuse (2A) | 2 pcs |
8 | 231 glass pH electrode | 2 pcs |
9 | 802 saturated calomel electrode | 2 pcs |
10 | Titration exchange unit (10mL) | 1 pcs |
11 | Agitator stabilized voltage supply (5V) | 1 pcs |
12 | 5ml(or 10ml) syringe | 1 pcs |
13 | Special size 9 injection needle | 1 pcs |
Acid Number Tester used in chemical industry, electric power, oil and other industries, it is ideal products to current meter acid number of petroleum products.
Graduated flask : 100 ml,50 ml
Conical flask : 100ml
Separatory funnel : 250ml
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Precision of titration tube : Scale division is 0.02 ml
Volumetric analysis : Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.02 ml
Automatic acid titration : Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.1 pH
Automatic potential control : Titration condensation: 0.1 N;
Controlling accuracy: ≤ 10 mV
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Capacity | 2.0 kVA |
Speed of voltage increase | 2 k V/ s |
Voltage inspection accuracy | 0.01 |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Electric Muffle Furnace |
|
||||||||||||||||
Temperature controller |
|
||||||||||||||||
Electric heating plate |
|
Measurement range | 32 ℃ to 160 ℃ |
Ambient temperature | 35 °C |
Temperature resolution | 0.01 ℃ |
Talk to us?