Automatic Bomb Calorimeter LABC-B10 comes with automatic oxygen filling and releasing, fully automatic bomb raising and lowering system. Equipped with propeller to achieve high stirring efficiency, and faster oxygen bomb heat transfer to reduce test period. It is in accordance with international standards ASTM D5865, ISO 1928.
Buy Now View CatalogCalorimeter type | Isoperibol |
Oxygen filling | Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering |
Bomb volume | 250 ml |
Analysis time | < 8 min full test process: <10 min |
Bomb washing | Manual |
Bomb pressure (maximum) | 20 MPa |
Bomb identity | Yes |
No. of Tests | 6/hour |
Temperature resolution | 0.0001 K |
Precision (RSD) | ≤ 0.01 % |
Heat Capacity Stability | ≤ 0.25 % within three months |
Gas requirement | 99.5 % oxygen |
Water requirements | Distilled water |
Energy measurement range | 0 to 50000 J |
Bucket filling | Automatic |
Stirring method | Propeller |
Reproducibility | 0.10 % (analysis of 1 g of benzoic acid) |
Temperature Increase | 2°C (average) |
Temperature measurement | PT1000 (temperature probe) |
Working temperatures | ≤ 32°C |
Cooling type | Refrigerating device |
Network | Yes |
Maximum Power | 0.6 kW |
Power Inverter | No |
Power supply | 220 V ±, 15 to 10 %, 50/60 Hz |
Advance Calculations | Yes |
Dimension | Main body: 440 × 550 × 460 mm Water Tank: 390 × 550 × 440 mm |
Weight | 50 kg |
Accessories no. | Name | Unit | Qty. |
1 | Ignition thread (500 pieces) Box | Box | 20 |
2 | Standard Benzoic Acid (1 gm * 10 pieces) | Bottle | 10 |
3 | Gasket Ring for Oxygen Filling Facility (big, middle, small) | Set | 15 |
4 | Heating Crucible | PC | 60 |
5 | Oxygen bomb gasket ring (big, middle, small) | Set | 15 |
6 | Plastic insulation cover | Set | 5 |
7 | Special Oxygen filling pipe | PC | 2 |
8 | Electrodes | Set | 1 |
Used in determination of calorific value of solid and liquid combustibles such as coal, coke, oil, petroleum material, biomass, cement and others.
Calorimeter type : Isoperibol
Temperature range : 5 to 40°C
Measurement range : 5 to 40 MJ/ kg
Calorimeter type : Isoperibol
Oxygen filling : Semi-automatic
Bomb volume : 282 ml
Calorimeter type : Isoperibol
Temperature range : 5 to 40°C
Measurement range : 5 to 40 MJ/ kg
Electric Muffle Furnace |
|
||||||||||||||||
Temperature controller |
|
||||||||||||||||
Electric heating plate |
|
Capacity | 2.0 kVA |
Speed of voltage increase | 2 k V/ s |
Voltage inspection accuracy | 0.01 |
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Measurement range | 32 ℃ to 160 ℃ |
Ambient temperature | 35 °C |
Temperature resolution | 0.01 ℃ |
Talk to us?