Fluorescence Spectrophotometer LFS-A12 consist of a high quality 150 W Xenon light source and photoelectric multiplier tube detectors for providing sufficient light intensity signal to detect sensitivity which ranges between 200 nm to 900 nm. Features fluorescence detection limit of ≤ 1×10-10 g/ml and Water Raman peak of S/N ≥ 150. It consists of the following characteristics, namely, high detection sensitivity, fast scanning speed, high dynamic range, fast 3D scanning, etc. The main principles includes measurement of absorption and fluorescence. Absorbance measurements can be taken via one or more wavelengths. The fluorescence unit increases the measuring range by 1000 for detecting DNA.
Buy Now View Catalog| Light source | 150 W Xenon lamp |
| Excitation wavelength | 200 nm to 900 nm |
| Emission wavelength | 200 nm to 900 nm |
| Excitation slit | 2 nm, 5 nm, 10 nm, 20 nm |
| Emission slit | 2 nm, 5 nm, 10 nm, 20 nm |
| Wavelength accuracy | ±1.0 nm |
| Wavelength repeatability | ≤ 0.5 nm |
| Signal-to-Noise Ratio | Raman peak of water (P-P): S/N ≥ 150 (10 nm Slit) |
| Detection limit | ≤1×10-10 g/ml (Quinine Sulphate Solution) |
| Linearity | γ ≥ 0.995 |
| Peak repeatability | ≤ 1.5% |
| Stability (10 min) Zero Drift | ±0.3 |
| Stability (10 min) Value Limit | ±1.5% |
| Wavelength scan speed | Multi-speed level, Maximum at 48000 nm/min |
| Photometric value | 0.00 to 10000.00 |
| Data interface | USB 2.0 |
| Maximum power consumption | 200 W |
| Power Source | AC 220 V/50 Hz; 110 V/60 Hz |
| Dimension | 380×445×310 mm |
| Net weight | 12 kg |
| Gross weight | 14 kg |
| Accessories No. | Accessories Name | Functions |
| 1 | Membrane sample rack | For membrane samples |
| 2 | Powder sample rack | For powder samples |
| 3 | Up conversion fluorescent holder | Base holder for other racks |
| 4 | Octave Double-frequency elimination filter (300 nm,350 nm,400 nm,450 nm,500 nm,550 nm,600 nm,650 nm for one set) | Remove the interference of double-frequency peaks of these wavelengths |
| 5 | Auto polarization filter | - |
| 6 | Sample cell jacket | - |
| 7 | Peltier temperature (15 to 40°C) control holder | - |
Fluorescence Spectrophotometer finds application in material research, pharmaceutical analysis, biochemical and clinical testing, water quality analysis and control, food safety testing.
Excitation Source : 150 W Xenon Lamp
Excitation Wavelength : 200 nm to 900 nm
Excitation Slit : 1 nm, 2 nm, 5 nm, 10 nm, 20 nm
Light source : 150 W Xenon lamp
Excitation wavelength : 200 nm to 900 nm
Emission wavelength : 200 nm to 900 nm
| Wavelength Range | 900 nm to 2500 nm |
| Wavelength Accuracy | ≤ 0.2 |
| Wavelength Reproducibility | ≤ 0.05 |
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
| Wavelength range | 200 - 800 nm |
| Path length | 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary) |
| Wavelength accuracy | ± 1 nm |
| Wavelength range | 200 - 850 nm |
| Path length | 1 mm, 2 mm, 5 mm, 10 mm |
| Wavelength accuracy | ± 1 nm |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
| Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
| Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
| Sensor | High sensitivity silicon photodiode |
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 1 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
| Wavelength range | 190 to 1100 nm |
| Spectral bandwidth | 2 nm |
| Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
| Wavelength range | 190 - 900 nm |
| Spectral Bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm |
| Wavelength accuracy | ≤ ± 0.5 nm |
| Working spectral range | 190 to 900 nm |
| Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
| Wavelength accuracy | ± 0.15 nm |