Portable Spectrophotometer LSP-A30

Portable Spectrophotometer LSP-A30 is adopted with 45/0 geometry (45 ring shaped illumination, 0 observe degree), where the standard white board is included in the optical system for great accuracy of every measurement. Large data storage space up to 20000 samples measurement records. The measurement of the color of the powder, granules and other materials can be done by adding the powder accessories to this spectrophotometer.

Buy Now View Catalog
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Test angle -
Test area -
Test range -
Test repeatability -
Reproducibility -
Inter instrument agreement 0.2 ΔE*ab (BCRA II color tiles, average test value of 12 tiles)
Illumination light source LED
Light source A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, NBF, TL83, TL184, NBF, U35
Wavelength range 400 nm to 700 nm
Wavelength interval 10 nm
Observation angle 2°/10°
Measuring aperture 11 mm
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, Hunter-lab, Munsell MI, CMYK
Color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*94, ΔE*00, ΔEab(Hunter), 555 shade sort
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz) Metamerism index Milm, Stick color fastness, Color fastness, ISO brightness, A density, T density, M density, E density.
Color matching system Not included
UV light source Not included
Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
Battery capacity Rechargeable Lithium battery, 20000 continuous measurement tests, 7.4V/600 mAh
Interface USB
Data storage 20000 samples
Display True color TFT touch screen
Light source longevity 10 years, 3 million test
Dimension 181 × 73 × 112 mm
Weight 800 g (without battery)
  • 2.8 inch TFT touch screen
    High capacity rechargeable lithium-ion battery
    LED light source for measurement accuracy
    Pre-locating panel design for instrument calibration
    SCS system for measurement repeatability
    Simultaneous measurement of SCI & SCE
    USB & Bluetooth data transmission
    Large storage capacity
    Connection to mini printer for printing
Accessories no. Accessories name Unit
1 AC adapter 1
2 Lithium battery 1
3 Color QC software 1
4 Driver software 1
5 USB cable 1
6 Calibration tile (black and white) 1
7 Carrying bag 1

Used in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.

{"Illumination":"45\/0 (45 ring shaped illumination,0\u00b0 observation angle)","Repeatability":"Light splitting reflectivity\uff1astandard deviation within 0.08%\nColor values: \u0394E*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)\nMaximum\uff1a0.05","Sensor":"High sensitivity silicon photodiode","Test angle":"-","Test area":"-","Test range":"-","Test repeatability":"-","Reproducibility":"-","Inter instrument agreement":"0.2 \u0394E*ab (BCRA II color tiles, average test value of 12 tiles)","Illumination light source":"LED","Light source":"A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, NBF, TL83, TL184, NBF, U35","Wavelength range":"400 nm to 700 nm","Wavelength interval":"10 nm","Observation angle":"2\u00b0\/10\u00b0","Measuring aperture":"11 mm","Color space":"CIE-L*a*b,\u00a0L*C*h,\u00a0L*u*v,\u00a0XYZ,\u00a0Yxy,\u00a0Reflectance, Hunter-lab, Munsell MI, CMYK","Color difference formula":"\u0394E*ab,\u00a0\u0394E*CH,\u00a0\u0394E*uv,\u00a0\u0394E*cmc(2:1),\u00a0\u0394E*cmc(1:1),\u0394E*94, \u0394E*00, \u0394Eab(Hunter), 555 shade sort","Other colorimetric indices":"WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE\/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby)\nYI (yellowness) (ASTM D1925\uff0cASTM E313-00,ASTM E313-73), Tint (ASTM E313,CIE,Ganz)\nMetamerism index Milm, Stick color fastness, Color fastness, ISO brightness, A density, T density, M density, E density.","Color matching system":"Not included","UV light source":"Not included","Work temperature range":"0 to 45\u2103, relative humidity 80% or below( at 35\u00b0C ),no condensation","Battery capacity":"Rechargeable Lithium battery, 20000 continuous measurement tests, 7.4V\/600 mAh","Interface":"USB","Data storage":"20000 samples","Display":"True color TFT touch screen","Light source longevity":"10 years, 3 million test","Dimension":"181 \u00d7 73 \u00d7 112 mm","Weight":"800 g (without battery)"}
2.8 inch TFT touch screen
High capacity rechargeable lithium-ion battery
LED light source for measurement accuracy
Pre-locating panel design for instrument calibration
SCS system for measurement repeatability
Simultaneous measurement of SCI & SCE
USB & Bluetooth data transmission
Large storage capacity
Connection to mini printer for printing
Used in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.


Related Products of Portable Spectrophotometer

Portable spectrophotometer LSP-A11

Portable spectrophotometer LSP-A11

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03

Sensor : Dual light path sensor array

Portable spectrophotometer LSP-A12

Portable spectrophotometer LSP-A12

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05

Sensor : Photoelectric diode sensor

Portable Spectrophotometer LSP-A31
Portable Spectrophotometer LSP-A31

Illumination : 45/0 (45 ring shaped illumination,0° observation angle)

Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05

Sensor : High sensitivity silicon photodiode

Portable Spectrophotometer LSP-A40
Portable Spectrophotometer LSP-A40

Optical Geometry : D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)

Integrating Sphere Size : Φ 40 mm

Light Source : LED (Full band balanced LED)

Portable spectrophotometer LSP-A20

Portable spectrophotometer LSP-A20

Illumination : Observation angles 2°/10°
Illumination: d/8 (Diffused lighting, 8° observation angle)
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04

Sensor : Dual light path sensor array

Portable Spectrophotometer LSP-C11

Portable Spectrophotometer LSP-C11

Reflect : 8º(diffused illumination, 8 degree viewing angle)

Optical Geometry : SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source

Standards : ISO7724-1, ASTM E1164, DIN5033 Teil7

Portable Spectrophotometer LSP-A41
Portable Spectrophotometer LSP-A41

Optical Geometry : D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded)

Integrating Sphere Size : Φ 40 mm

Light Source : LED (Full band balanced LED)

Portable spectrophotometer LSP-A10
Portable spectrophotometer LSP-A10

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05

Sensor : Blue light enhanced sensor array

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer LFS-A10

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Fluorescence Spectrophotometer LFS-A12

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B31
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Double Beam UV/Vis Spectrophotometer LUS-B30
Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A13

Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm

Atomic Absorption Spectrophotometer LAAS-A11

Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A10
Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm
Nano Spectrophotometer LNS-A21
Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm

NIR Spectrophotometer

NIR Spectrophotometer LNIR-A10

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05