Flame Atomic Absorption Spectrophotometer LAAS-A13 is a microprocessor controlled instrument based on analysis of metal ions by flame and graphite furnace atomizer with their absorption at wavelength of 190 to 900 nm. Czerny-Turner monochromator and variance of bandwidth provides user flexibility. It is provided with deuterium hollow cathode lamp to exclude interference of molecular absorption and Titanium Burner to increase the analysis efficiency and precision of flame. Its double beam radiation sources enables good basic line stability. Graphic analysis system provides data on analysis of entire process e.g. measured value, temperature, procedures, time, etc. It has great applications in research, medicine, environmental science and other industries.
Buy Now View CatalogWorking spectral range | 190 to 900 nm |
Spectral Bandwith | 0.1, 0.2, 0.4, 1.0 and 2.0 nm |
Wavelength accuracy | ± 0.15 nm |
Wavelength repeatability | ≤ 0.04 nm |
Baseline stability | ≤ 0.002 Abs / 30 min |
Characteristic concentration of copper | 0.02 μg / ml / 1 % |
Detection limit of copper | 0.004 μg / ml |
Measurement Repeatability | 0.005 |
Grating | 1800 lines / mm |
Inflamer | All-metal titanium burner |
Atomizer | Efficient glass atomizer |
Lamp stand | 8 lamps automatic turret, automatic alignment |
D2 Background calibration ability | 1 A ≤ 30 times correction ability |
Dimensions | 700 × 550 × 450 mm |
Net weight | 75 Kg |
Power supply | 220 V ± 22 V AC |
Acetylene air burner | 100 mm |
Ignition dynamic baseline drift | ≤ 0.006 Abs / 30 min |
Characteristic viscocity | ≤ 0.025 μg / ml / 1 % |
Standard deviation of the accuracy | ≤ 0.5 % (Cu, absorbance > 0.8 A) (detection limit Cu ≤ 0.008 μg / ml) |
Protection system | Can inevitably cut off gas if pressure is low, power cut-off, flame out and alteration of the burner |
Accessories no. | Name |
1 | PC workstation |
2 | Printer |
3 | Oil free Air compressor |
4 | Acetylene reducing valve |
5 | Cu - Hollow cathode lamp |
6 | Air filter |
GRAPHITE FURNACE | |
Maximum temperature | 3000 ℃ |
Temperature increasing speed | ≥ 2000 ℃ / S |
Characteristic quantity | (Cd) ≤ 0.5 × 10 to 12g , (Cu) ≤ 0.5 × 10 to 11g |
Accuracy | (Cu) ≤3 % , (Cd) ≤ 3 % |
Dimension | 550 × 450 × 300 mm |
Net weight | 65 Kg |
Safety system | Protection for Overload current, reduced air pressure, low cooling water flow |
Power supply | 220 V ± 22 V AC, 7000 W |
It is suitable to analyse trace amount of element from mixture, also in forensics and chemistry, biological science to detect toxic elements from blood and drug samples.
Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.
Wavelength range : 180 – 900 nm
Spectral Bandwidth : 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting
Wavelength accuracy : ≤ 0.15 nm
Wavelength range : 190 - 900 nm
Spectral Bandwidth : 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy : ≤ ± 0.5 nm
Wavelength range : 180 – 900 nm
Spectral Bandwidth : 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)
Wavelength accuracy : ≤ 0.15 nm
Wavelength range : 190 nm ~ 900 nm
Spectral bandwidth : 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm
Wavelength accuracy : ± 0.25 nm
Wavelength range : 180 - 900 nm
Spectral Bandwidth : 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy : ≤ 0.15 nm
Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 2 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength range | 190 to 1100 nm |
Spectral bandwidth | 1 nm |
Wavelength Accuracy | ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all |
Wavelength Range | 900 nm to 2500 nm |
Wavelength Accuracy | ≤ 0.2 |
Wavelength Reproducibility | ≤ 0.05 |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Illumination | 45/0 (45 ring shaped illumination,0° observation angle) |
Repeatability | Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 |
Sensor | High sensitivity silicon photodiode |
Light source | 150 W Xenon lamp |
Excitation wavelength | 200 nm to 900 nm |
Emission wavelength | 200 nm to 900 nm |
Light source | 150 W Xenon lamp |
Excitation wavelength | 200 nm to 900 nm |
Emission wavelength | 200 nm to 900 nm |
We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.
Wavelength range | 200 - 850 nm |
Path length | 1 mm, 2 mm, 5 mm, 10 mm |
Wavelength accuracy | ± 1 nm |
Wavelength range | 200 - 800 nm |
Path length | 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary) |
Wavelength accuracy | ± 1 nm |