Atomic Absorption Spectrophotometer LAAS-A20

Atomic absorption spectrophotometer designed with the latest technology, can automatically accomplish safety ignition and reproducibility of the flame method. The graphic analysis system gives information on analysis of the whole process e.g. measured value, temperature, procedures, time, etc. It consist of hollow cathode lamp to improve the analysis efficiency and accuracy of the flame & deuterium lamp for background correction.

Buy Now View Catalog
Monochromator
Wavelength range 180 - 900 nm
Spectral Bandwidth 0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)
Wavelength accuracy ≤ 0.15 nm
Wavelength repeatability ± 0.1 nm
Baseline drift ≤ ± 0.002 Abs / 30 min (Static), ≤ ± 0.005 Abs / 30 min (Dynamic)
Grating groove density
Sample Volume
The volume of sample
Repeated Sampling Frequency
Cleaning and waste container volume
Absorbance Range 0 - 4 A
The Program
Temperature Range
Detector Imported photomultiplier tube
Heating Mode
Temperature Control Method
Temperature Control
Resolution
Lamp holder ≤ 6 lamps automatic turret, automatic alignment
Lamp current adjustment range
Lamp power supply mode pulsed power supply
Optical System large 1800 /mm grating ruling, full closed optical system
Atomization Chamber Polymer explosion-proof spray chamber
Characteristics Volume
Characteristic concentration (Cu) 0.015 μg / mL / 1 %
Detection Limit
Detection Limit (Cu) 0.002 μg/mL
Background calibration ability
Burner Full titanium combustion head, 50 mm or 100 mm general combustion head
Nebulizer Atomizer efficient glass atomizer,can also be customized
Precision RSD ≤ 0.5 %
Ignition Type Microcomputer control, automatic ignition
Sprayer
Room Spray
Sample Tray
The Smallest Lincrement
Safety measures
Gas Control Automatic gas control system
Measurement Flame method, Hydride generation-Atomic absorption method
Concentration calculation Standard curve method(1 - 3 times curve), automatic fitting
The Cooling Water
The number of repeated measurements 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.
Print results Print the final stages of test data or analysis. The results can be exported into Excel worksheet.
Software Environment
Operating temperature
Working humidity
Power supply 110 / 220 V (+5 % ~ (-10) %), 60 / 50 Hz; 5000 VA
Power (VAC)
Gross Weight
Weight
Dimension (L × W × H)
  • 1800 /mm reticle (dispersion rate) large area grating Monochromator
    Titanium burner for the flame analysis
    Polymer automization chamber
    Automatic analysis ensures sensitivity and reproducibility of the flame method
    Light source 6 lamp holder
    Graphic furnace system gives information on analysis of the whole process
    Convenient data processing & sharing & printing
    Powerful software with automatic instrument and additional control

Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.

{"Monochromator":"","Wavelength range":"180 - 900 nm","Spectral Bandwidth":"0, 0.2, 0.4, 1.0, 2.0nm (Automatic setting)","Wavelength accuracy":"\u2264 0.15 nm","Wavelength repeatability":"\u00b1 0.1 nm","Baseline drift":"\u2264 \u00b1 0.002 Abs \/ 30 min (Static), \u2264 \u00b1 0.005 Abs \/ 30 min (Dynamic)","Grating groove density":"","Sample Volume":"","The volume of sample":"","Repeated Sampling Frequency":"","Cleaning and waste container volume":"","Absorbance Range":"0 - 4 A","The Program":"","Temperature Range":"","Detector":"Imported photomultiplier tube","Heating Mode":"","Temperature Control Method":"","Temperature Control":"","Resolution":"","Lamp holder":"\u2264 6 lamps automatic turret, automatic alignment","Lamp current adjustment range":"","Lamp power supply mode":"pulsed power supply","Optical System":"large 1800 \/mm grating ruling, full closed optical system","Atomization Chamber":"Polymer explosion-proof spray chamber","Characteristics Volume":"","Characteristic concentration (Cu)":"0.015 \u03bcg \/ mL \/ 1 %","Detection Limit":"","Detection Limit (Cu)":"0.002 \u03bcg\/mL","Background calibration ability":"","Burner":"Full titanium\u00a0combustion head,\u00a050 mm or\u00a0100 mm general combustion head","Nebulizer":"Atomizer efficient glass atomizer,can also be customized","Precision":"RSD \u2264 0.5 %","Ignition Type":"Microcomputer control, automatic ignition","Sprayer":"","Room Spray":"","Sample Tray":"","The Smallest Lincrement":"","Safety measures":"","Gas Control":"Automatic\u00a0gas control system","Measurement":"Flame method, Hydride generation-Atomic absorption method","Concentration calculation":"Standard curve method(1 - 3 times curve), automatic fitting","The Cooling Water":"","The number of repeated measurements":"1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation.","Print results":"Print the final stages of test data or analysis.\u00a0The results can be exported into Excel worksheet.","Software Environment":"","Operating temperature":"","Working humidity":"","Power supply":"110 \/ 220 V (+5 % ~ (-10) %), 60 \/ 50 Hz; 5000 VA","Power (VAC)":"","Gross Weight":"","Weight":"","Dimension (L \u00d7 W \u00d7 H)":""}
1800 /mm reticle (dispersion rate) large area grating Monochromator
Titanium burner for the flame analysis
Polymer automization chamber
Automatic analysis ensures sensitivity and reproducibility of the flame method
Light source 6 lamp holder
Graphic furnace system gives information on analysis of the whole process
Convenient data processing & sharing & printing
Powerful software with automatic instrument and additional control
Atomic absorption spectrophotometer is widely used in analysis of elements from the mixture in scientific research, environmental science, metallurgy, agriculture & chemical industry, food, mining, and petrochemical, pharmaceutical industries.


Related Products of Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A13

Atomic Absorption Spectrophotometer LAAS-A13

Working spectral range : 190 to 900 nm

Spectral Bandwith : 0.1, 0.2, 0.4, 1.0 and 2.0 nm

Wavelength accuracy : ± 0.15 nm

Atomic Absorption Spectrophotometer LAAS-A22

Atomic Absorption Spectrophotometer LAAS-A22

Wavelength range : 180 – 900 nm

Spectral Bandwidth : 0.1 nm,0.2 nm,0.4 nm, 1.0 nm, 2.0 nm automatic setting

Wavelength accuracy : ≤ 0.15 nm

Flame Atomic Absorption Spectrophotometer LAAS-A12
Flame Atomic Absorption Spectrophotometer LAAS-A12

Wavelength range : 190 nm ~ 900 nm

Spectral bandwidth : 0.1 nm, 0.2 nm, 1.0 nm, 2.0 nm

Wavelength accuracy : ± 0.25 nm

Atomic Absorption Spectrophotometer LAAS-A11
Atomic Absorption Spectrophotometer LAAS-A11

Wavelength range : 190 - 900 nm

Spectral Bandwidth : 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm

Wavelength accuracy : ≤ ± 0.5 nm

Atomic Absorption Spectrophotometer LAAS-A21

Atomic Absorption Spectrophotometer LAAS-A21

Wavelength range : 180 – 900 nm

Spectral Bandwidth : 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover)

Wavelength accuracy : ≤ 0.15 nm

NIR Spectrophotometer

NIR Spectrophotometer LNIR-A10

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer LFS-A10

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Fluorescence Spectrophotometer LFS-A12
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A21
Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm

Nano Spectrophotometer LNS-A10

Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm

Portable Spectrophotometer

Portable Spectrophotometer LSP-A31

Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode
Portable Spectrophotometer LSP-A30
Illumination 45/0 (45 ring shaped illumination,0° observation angle)
Repeatability Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05
Sensor High sensitivity silicon photodiode

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B31
Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV/Vis Spectrophotometer LUS-B30

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Talk to us?