Portable spectrophotometer LSP-A20

Portable spectrophotometer LSP-A20 is adopted with every test calibration ETC technology, where the standard white boards included in the optical system for reliable, accuracy of every measurement. The pulse xenon lamp is used for measurement of UV samples with wide wavelength range. Its Built-in camera helps to view measured area precisely. The automatic gloss compensation technology helps in measurement data for the surface of different gloss.

Buy Now View Catalog
Illumination Observation angles 2°/10°
Illumination: d/8 (Diffused lighting, 8° observation angle)
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement
Repeatability Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
Sensor Dual light path sensor array
Size of integrated sphere 40 mm, alvan diffused reflection surface coating
Illumination light source Pulse Xenon Lamp
Light source A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, U35, CWF
Wavelength range 360-740 nm
Wavelength interval 10 nm
Half spectral width 5 nm
Reflectivity range & resolution 0 to 200%, 0.01%
Observation angle 2°/10°
Measurement time interval 2 seconds
Measurement time 2 seconds
Measuring aperture 8 mm
Color space CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK, RGB, HSB
Color difference formula ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1), ΔE*94,ΔE*00,ΔEab(Hunter),555 , color classification
Other colorimetric indices WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby)
YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz)
Metamerism index Milm, adhesive, Staining fastness, color fastness, ISO b/changing Color fastness, ISO brightness, 8 glossiness, A , T, M, E density
Color matching system Matches
UV light source Included
Work temperature range 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation
Storage temperature range 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation
Battery capacity
Data being displayed Reflective graph/value,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report
Interface USB, Bluetooth
Data storage 100 test samples , 200 measurement records for each sample
Display True color TFT touch screen
Light source longevity 10 years, 3 million tests
Dimension (L*W*H) 181 × 73 × 112 mm
Weight 550 g
  • 2.8 inch TFT touch screen
    Built-in camera to view measured area
    High capacity rechargeable lithium-ion battery
    CLED light source for measurement accuracy
    SCS system for measurement repeatability
    Simultaneous measurement of SCI & SCE
    Equipped with gloss compensation technology
    USB & Bluetooth data transmission
    Customized for PANTONE color matching technology
    Large storage capacity
    Connection to mini printer for printing
Accessories No. Name
1 Power cord
2 USB cable
3 Driving software
4 Color QC software
5 Black and white calibration tile

Portable spectrophotometer has applications in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.

{"Illumination":"Observation angles 2\u00b0\/10\u00b0\nIllumination: d\/8 (Diffused lighting, 8\u00b0 observation angle)\nSCI (specular reflection included) & SCE(specular reflection excluded)\nsimultaneous measurement","Repeatability":"Light splitting reflectivity\uff1astandard deviation within 0.08%\nColor values:\u0394E*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum\uff1a0.04","Sensor":"Dual light path sensor array","Size of integrated sphere":"40 mm, alvan diffused reflection surface coating","Illumination light source":"Pulse Xenon Lamp","Light source":"A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, U35, CWF","Wavelength range":"360-740 nm","Wavelength interval":"10 nm","Half spectral width":"5 nm","Reflectivity range & resolution":"0 to 200%, 0.01%","Observation angle":"2\u00b0\/10\u00b0","Measurement time interval":"2 seconds","Measurement time":"2 seconds","Measuring aperture":"8 mm","Color space":"CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK, RGB, HSB","Color difference formula":"\u0394E*ab,\u0394E*CH,\u0394E*uv,\u0394E*cmc(2:1),\u0394E*cmc(1:1), \u0394E*94,\u0394E*00,\u0394Eab(Hunter),555\n, color classification","Other colorimetric indices":"WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE\/ISO, AATCC, Hunter, Taube Berger,\n Ganz, Stensby)\nYI (yellowness) (ASTM D1925\uff0cASTM E313-00,ASTM E313-73),\nTint(ASTM E313,CIE,Ganz)\nMetamerism index Milm, adhesive, Staining fastness, color fastness, ISO b\/changing Color fastness, ISO brightness, 8 glossiness, A , T, M, E density","Color matching system":"Matches","UV light source":"Included","Work temperature range":"0 to 45\u2103, relative humidity 80% or below( at 35\u00b0C ),no condensation","Storage temperature range":"25\u2103 to 55\u2103 relative humidity 80% or below(at 35\u00b0C ),no condensation","Battery capacity":"","Data being displayed":"Reflective graph\/value\uff0csamples\u00a0color\u00a0values\uff0ccolor\u00a0difference\u00a0values\/graph\uff0cpass\/fail\u00a0results,color\u00a0error\u00a0tendency\uff0ccolor\u00a0simulation display\u00a0measurement\u00a0area\uff0chistory\u00a0data\u00a0color\u00a0simulation\uff0cmanual\u00a0input\u00a0standard\u00a0sample generate\u00a0measurement\u00a0report","Interface":"USB, Bluetooth","Data storage":"100 test samples , 200 measurement records for each sample","Display":"True color TFT touch screen","Light source longevity":"10 years, 3 million tests","Dimension (L*W*H)":"181 \u00d7 73 \u00d7 112 mm","Weight":"550 g"}
2.8 inch TFT touch screen
Built-in camera to view measured area
High capacity rechargeable lithium-ion battery
CLED light source for measurement accuracy
SCS system for measurement repeatability
Simultaneous measurement of SCI & SCE
Equipped with gloss compensation technology
USB & Bluetooth data transmission
Customized for PANTONE color matching technology
Large storage capacity
Connection to mini printer for printing
Portable spectrophotometer has applications in textile, plastic, food, paint, printing, automobile industries, laboratories & on-site applications for quality control purpose.


Related Products of Portable Spectrophotometer

Portable Spectrophotometer LSP-C11

Portable Spectrophotometer LSP-C11

Reflect : 8º(diffused illumination, 8 degree viewing angle)

Optical Geometry : SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source

Standards : ISO7724-1, ASTM E1164, DIN5033 Teil7

Portable spectrophotometer LSP-A10

Portable spectrophotometer LSP-A10

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05

Sensor : Blue light enhanced sensor array

Portable Spectrophotometer LSP-A30
Portable Spectrophotometer LSP-A30

Illumination : 45/0 (45 ring shaped illumination,0° observation angle)

Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05

Sensor : High sensitivity silicon photodiode

Portable Spectrophotometer LSP-C10
Portable Spectrophotometer LSP-C10

Reflect : 8º(diffused illumination, 8 degree viewing angle)

Optical Geometry : SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source

Standards : ISO7724-1, ASTM E1164, DIN5033 Teil7

Portable spectrophotometer LSP-A13

Portable spectrophotometer LSP-A13

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.04

Sensor : Photoelectric diode sensor

Portable spectrophotometer LSP-A12

Portable spectrophotometer LSP-A12

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05

Sensor : Photoelectric diode sensor

Portable Spectrophotometer LSP-A40
Portable Spectrophotometer LSP-A40

Optical Geometry : D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)

Integrating Sphere Size : Φ 40 mm

Light Source : LED (Full band balanced LED)

Portable spectrophotometer LSP-A11
Portable spectrophotometer LSP-A11

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03

Sensor : Dual light path sensor array

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B31

Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV/Vis Spectrophotometer LUS-B30

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A11
Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm
Atomic Absorption Spectrophotometer LAAS-A13
Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm

NIR Spectrophotometer

NIR Spectrophotometer LNIR-A10

Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer LFS-A12

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Fluorescence Spectrophotometer LFS-A10
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A10
Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm

Nano Spectrophotometer LNS-A21

Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm

Talk to us?