Portable Spectrophotometer LSP-C11

Portable Spectrophotometer LSP-C11 adopts 1000 line precision blazed grating as the spectroscopic element, the silicon photocell array with large photosensitive area as the detector. The full spectrum LED with high life as the light source, and the optical resolution is less than 10 nm in the visible light range. Under the condition of d/8 geometric optical illumination recommended by CIE, spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples. It has stable performance, accurate color measurement and powerful function.

Buy Now View Catalog
Reflect 8º(diffused illumination, 8 degree viewing angle)
Optical Geometry SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
Standards ISO7724-1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size Φ 40 mm
Light Source Combined full spectrum LED light source, UV light source
Spectrophotometric Mode Flat Grating
Sensor Silicon photodiode array (double row 40 groups)
Wavelength Range 400 to 700 nm
Wavelength Interval 10 nm
Semi band Width 10 nm
Measured Reflectance Range 0 to 200%
Measuring Aperture MAV Φ8 mm / Φ10 mm SAV Φ4 mm / Φ5 mm
Specular Component SCI & SCE
Color Space CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, βxy,DIN, Munsell (C/2)
Color Difference Formula ΔE×ab, ΔE×uv, ΔE×94, ΔE×cmc(2:1), ΔE×cmc(1:1), ΔE×00
Other Colorimetric Index WI (ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness, 555 tone classification
Illuminant D65, A , C, D50, F2(CWF), F7(DLF), F10(TPL5), F11(TL84), F12(TL83/U30)
Observer Angle 2° / 10°
Measuring Time About 1.5 s (Measure SCI & SCE about 3.2 s)
Repeatability Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) Chromaticity value: MAV/SCI, within ΔE × ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error MAV/SCI, Within ΔE×ab0.2 (Average for 12 BCRA Series II color tiles)
Measurement Mode Single Measurement, Average Measurement(2 to 99 times)
Locating Method Camera Locating, stabilizer cross position
Displayed Data 3.5 inch TFT color LCD, Capacitive Touch Screen
Data Port USB
Data Storage Standard 1000 Pcs, Sample 20000 Pcs
Language English
Operating temperature 0 to 40ºC
Operating humidity 0 to 85 % RH
Dimension 129 × 76 × 217 mm
Battery Li-ion battery, 6000 measurements within 8 hours
Weight Approx. 600 g
  • Designed with combined LED light source with high life and low power consumption, including UV / excluding UV
    Dual optical path system, the optical resolution in the visible range is less than 10 nm
    It measures the SCI and SCE spectrum of the sample at the same time
    Accurate spectrum and lab data, used for color matching and accurate color transmission
    USB / Bluetooth dual communication mode, wider adaptability
    Large capacity storage space, which can store more than 30000 pieces of test data
    Camera locating position and Stabilizer cross measurement position
    PC software has powerful function expansion
Accessories no.Name
1Power Adapter
2User Guide
3PC Software
4USB cable
5White and Black Calibration Cavity
6Protective Cover
7Wrist strap
8One aperture 8mm or 4mm

Portable Spectrophotometer is used in plastic electronics, paint and coating, textile printing and dyeing, printing paper, automobile, medical treatment, cosmetics and food industries, as well as scientific research institutions and laboratories etc.

{"Reflect":"8\u00ba(diffused illumination, 8 degree viewing angle)","Optical Geometry":"SCI (specular component included)\/SCE (specular component excluded) Include UV \/ excluded UV light source","Standards":"ISO7724-1, ASTM E1164, DIN5033 Teil7","Integrating Sphere Size":"\u03a6 40 mm","Light Source":"Combined full spectrum LED light source, UV light source","Spectrophotometric Mode":"Flat Grating","Sensor":"Silicon photodiode array (double row 40 groups)","Wavelength Range":"400 to 700 nm","Wavelength Interval":"10 nm","Semi band Width":"10 nm","Measured Reflectance Range":"0 to 200%","Measuring Aperture":"MAV \u03a68 mm \/ \u03a610 mm SAV \u03a64 mm \/ \u03a65 mm","Specular Component":"SCI & SCE","Color Space":"CIE LAB, XYZ, Yxy, LCh, CIE LUV, \ns-RGB, \u03b2xy,DIN, Munsell (C\/2)","Color Difference Formula":"\u0394E\u00d7ab, \u0394E\u00d7uv, \u0394E\u00d794, \u0394E\u00d7cmc(2:1), \u0394E\u00d7cmc(1:1), \u0394E\u00d700","Other Colorimetric Index":"WI (ASTM E313\uff0cCIE\/ISO, AATCC, Hunter), YI(ASTM D1925\uff0c ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8\u00b0 Glossiness, 555 tone classification","Illuminant":"D65, A , C, D50, F2(CWF), F7(DLF), F10(TPL5), F11(TL84),\nF12(TL83\/U30)","Observer Angle":"2\u00b0 \/ 10\u00b0","Measuring Time":"About 1.5 s (Measure SCI & SCE about 3.2 s)","Repeatability":"Spectral reflectance: MAV\/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) Chromaticity value: MAV\/SCI, within \u0394E \u00d7 ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)","Inter-instrument Error":"MAV\/SCI, Within \u0394E\u00d7ab0.2 (Average for 12 BCRA Series II color tiles)","Measurement Mode":"Single Measurement, Average Measurement(2 to 99 times)","Locating Method":"Camera Locating, stabilizer cross position","Displayed Data":"3.5 inch TFT color LCD, Capacitive Touch Screen","Data Port":"USB","Data Storage":"Standard 1000 Pcs, Sample 20000 Pcs","Language":"English","Operating temperature":"0 to 40\u00baC","Operating humidity":"0 to 85 % RH","Dimension":"129 \u00d7 76 \u00d7 217 mm","Battery":"Li-ion battery, 6000 measurements within 8 hours","Weight":"Approx. 600 g"}
Designed with combined LED light source with high life and low power consumption, including UV / excluding UV
Dual optical path system, the optical resolution in the visible range is less than 10 nm
It measures the SCI and SCE spectrum of the sample at the same time
Accurate spectrum and lab data, used for color matching and accurate color transmission
USB / Bluetooth dual communication mode, wider adaptability
Large capacity storage space, which can store more than 30000 pieces of test data
Camera locating position and Stabilizer cross measurement position
PC software has powerful function expansion
Portable Spectrophotometer is used in plastic electronics, paint and coating, textile printing and dyeing, printing paper, automobile, medical treatment, cosmetics and food industries, as well as scientific research institutions and laboratories etc.


Related Products of Portable Spectrophotometer

Portable Spectrophotometer LSP-C10

Portable Spectrophotometer LSP-C10

Reflect : 8º(diffused illumination, 8 degree viewing angle)

Optical Geometry : SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source

Standards : ISO7724-1, ASTM E1164, DIN5033 Teil7

Portable Spectrophotometer LSP-A30

Portable Spectrophotometer LSP-A30

Illumination : 45/0 (45 ring shaped illumination,0° observation angle)

Repeatability : Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05

Sensor : High sensitivity silicon photodiode

Portable spectrophotometer LSP-A12
Portable spectrophotometer LSP-A12

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05

Sensor : Photoelectric diode sensor

Portable spectrophotometer LSP-A11
Portable spectrophotometer LSP-A11

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03

Sensor : Dual light path sensor array

Portable spectrophotometer LSP-A13

Portable spectrophotometer LSP-A13

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.04

Sensor : Photoelectric diode sensor

Portable Spectrophotometer LSP-A40

Portable Spectrophotometer LSP-A40

Optical Geometry : D/8 (diffused illumination,8° viewing), Specular Component Included (SCI)

Integrating Sphere Size : Φ 40 mm

Light Source : LED (Full band balanced LED)

Portable spectrophotometer LSP-A20
Portable spectrophotometer LSP-A20

Illumination : Observation angles 2°/10°
Illumination: d/8 (Diffused lighting, 8° observation angle)
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04

Sensor : Dual light path sensor array

Portable spectrophotometer LSP-A10
Portable spectrophotometer LSP-A10

Illumination : d/8 (Diffused lighting, 8° observation angle)
SCS optical engine (light splitting and integration system)
ETC (real time calibration technology )
SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement

Repeatability : Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05

Sensor : Blue light enhanced sensor array

Double Beam UV/Vis Spectrophotometer

Our range of Double Beam UV/VIS spectrophotometers offer long optical path which ensure high accuracy and stability. Its design measures the transmittance of the sample and solvent simultaneously. It is highly precise and performs powerful analysis.

Double Beam UV/Vis Spectrophotometer LUS-B31

Wavelength range 190 to 1100 nm
Spectral bandwidth 1 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

Double Beam UV/Vis Spectrophotometer LUS-B30

Wavelength range 190 to 1100 nm
Spectral bandwidth 2 nm
Wavelength Accuracy ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all

NIR Spectrophotometer

NIR Spectrophotometer LNIR-A10
Wavelength Range 900 nm to 2500 nm
Wavelength Accuracy ≤ 0.2
Wavelength Reproducibility ≤ 0.05

Nano Spectrophotometer

We produce a wide range of Nano spectrophotometer for qualitative and quantitative analysis of DNA/RNA in the sample. Our product is highly sensitive and requires only 0.5-2µl of sample for analysis.

Nano Spectrophotometer LNS-A10
Wavelength range 200 - 800 nm
Path length 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary)
Wavelength accuracy ± 1 nm

Nano Spectrophotometer LNS-A21

Wavelength range 200 - 850 nm
Path length 1 mm, 2 mm, 5 mm, 10 mm
Wavelength accuracy ± 1 nm

Fluorescence Spectrophotometer

Fluorescence Spectrophotometer LFS-A12

Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm
Fluorescence Spectrophotometer LFS-A10
Light source 150 W Xenon lamp
Excitation wavelength 200 nm to 900 nm
Emission wavelength 200 nm to 900 nm

Atomic Absorption Spectrophotometer

Labtron Atomic Absorption Spectrophotometer makes use of the modern in technology. It is acquired after thorough research into the desires of the diagnostic community. It has all the power, performance and speed necessitated in today’s modern laboratory.

Atomic Absorption Spectrophotometer LAAS-A13
Working spectral range 190 to 900 nm
Spectral Bandwith 0.1, 0.2, 0.4, 1.0 and 2.0 nm
Wavelength accuracy ± 0.15 nm

Atomic Absorption Spectrophotometer LAAS-A11

Wavelength range 190 - 900 nm
Spectral Bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength accuracy ≤ ± 0.5 nm