Analytical HPLC-A7835 system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time.
Buy Now View CatalogPump Specifications |
|
Detector Specifications |
|
Accessory | Quantity |
Pump | 2 |
UV-Vis detector ( without flow cell ) | 1 |
Analytical flow cell | 1 |
Injection valve | 1 |
20 μl sample loop | 1 |
4.6 x 250 mm ( 5μm ) analytical column | 1 |
Solvent tray | 1 |
Binary gradient kit | 1 |
Mixing chamber | 1 |
Accessory | Quantity |
Autosampler | 1 |
Fraction collector | 1 |
Column oven | 1 |
Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysis
High Pressure Constant Flow Pump :
UV/Visible Detector :
High Pressure Constant Flow Pump :
UV/Visible Detector :
Detector Specifications :
Model No | HPD-A20 | HPD-A21 |
Wavelength range | Single wavelength ( 190 to 800 nm ) | Dual wavelength ( 190 to 800 nm ) |
Wavelength accuracy | ± 0.5 nm | ± 2 nm |
Wavelength repeatability | 0.15 nm | 0.3 nm |
Band width | 8 nm | 8 nm |
Optical path | 10 nm | 10 nm |
Deuterium lamp | 190 to 400 nm | 190 to 400 nm |
Tungsten lamp | 400 to 800 nm | 400 to 800 nm |
Baseline noise ( Static ) Au | ≤ ± 0.35 × 10-5 | ≤ ± 0.5 × 10-5 |
Baseline drift ( Static ) Au / h | ≤ 1 × 10-4 | ≤ 1.5 × 10-4 |
Minimum detection limit | ≤ 4 × 10-8 | ≤ 4 × 10-8 |
Power | 100 W | 100 W |
Power supply | 90 V / 50 to 60 Hz | 90 V / 50 to 60 Hz |
Dimension | 460 × 315 × 180 mm | 460 × 315 × 180 mm |
Weight | 9.5 kg | 9.5 kg |
Pump Specifications :
Pump specification :
UV/VIS Detector :
Data-processing Workstation : System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA
Pump Specifications :
Detector Specifications :
High pressure pump | Single pump |
Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increment) |
Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |
High pressure pump | Two sets of pump |
Flow rate range | 0.001 - 9.999 mL / min (0.001 mL / min increments) |
Pressure range | ≤ 0.5 MPa (0 - 42 MPa) |