HPLC system LHLC-A10

This HPLC system is equipped with high-pressure constant-current pump and UV detector. Pressure pulsation is controlled by diaphragmatic damper in seconds. The UV detectors helps in identification of samples and elutes that are colourless, odourless in nature. There is auto boot detection function available in this HPLC system.

Buy Now View Catalog
High pressure pump Single pump
Flow rate range 0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range ≤ 0.5 MPa (0 - 42 MPa)
Flow rate precision RSD < 0.06 %
Pulsation ≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa)
Qualitative analysis RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent)
Quantitative repeatability RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent)
Flow rate setting error Ss ≤ 2 % (1 mL / min water, 5 - 10 MPa, room temperature)
Air tightness of the pump
Mixing accuracy ± 1 %
Mixing precision ± 0.2 %
Size (W × H × D) 450 × 300 × 160 mm
UV Detector
  • Wavelength range: 190 - 680 nm
  • Flow cell: 8 µL
  • Spectrum band width: 8 nm
  • Baseline noise: ≤ ± 0.25 × 10-5 AU (empty cell)
  • Wavelength accuracy: ± 1 nm
  • Baseline drift: ≤ ± 0.4 × 10-4 AU (empty cell)
  • Wavelength precision: < 0.1 nm
  • Limit of detection: 3 × 10-9 g / mL (naphthalene methyl alcohol solvent)
  • Size (W × H × D): 450 × 300 × 160 mm
  • Limit baseline noise can be ensured using electronic pulse suppression technique
    High pressure single pump
    Easy to change gasket ring & automatic washing function for the column
    User-friendly software for smooth operations

The HPLC has applications in separation of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

{"High pressure pump":"Single pump","Flow rate range":"0.001 - 9.999 mL \/ min (0.001 mL \/ min increment)","Pressure range":"\u2264 0.5 MPa (0 - 42 MPa)","Flow rate precision":"RSD < 0.06 %","Pulsation":"\u2264 0.1 MPa (flow rate 1 ml \/ min, Pressure 5 - 10 MPa)","Qualitative analysis":"RSD 6 \u2264 0.1 % (naphthalene methyl alcohol solvent)","Quantitative repeatability":"RSD 6 \u2264 0.3 % (naphthalene methyl alcohol solvent)","Flow rate setting error":"Ss \u2264 2 % (1 mL \/ min water, 5 - 10 MPa, room temperature)","Air tightness of the pump":"","Mixing accuracy":"\u00b1 1 %","Mixing precision":"\u00b1 0.2 %","Size (W \u00d7 H \u00d7 D)":"450 \u00d7 300 \u00d7 160 mm","UV Detector":{"Wavelength range":"190 - 680 nm","Flow cell":"8 \u00b5L","Spectrum band width":"8 nm","Baseline noise":"\u2264 \u00b1 0.25 \u00d7 10-5<\/sup> AU (empty cell)","Wavelength accuracy":"\u00b1 1 nm","Baseline drift":"\u2264 \u00b1 0.4 \u00d7 10-4<\/sup> AU (empty cell)","Wavelength precision":"< 0.1 nm","Limit of detection":"3 \u00d7 10-9<\/sup> g \/ mL (naphthalene methyl alcohol solvent)","Size (W \u00d7 H \u00d7 D)":"450 \u00d7 300 \u00d7 160 mm"}}
Limit baseline noise can be ensured using electronic pulse suppression technique
High pressure single pump
Easy to change gasket ring & automatic washing function for the column
User-friendly software for smooth operations
The HPLC has applications in separation of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.


Related Products of Standard HPLC

HPLC system LHLC-B11

HPLC system LHLC-B11

High pressure pump : High pressure constant-current infusion pump

Infusion Way : Micro volume series dual-piston

Infusion pressure : 0 - 9999 Psi

HPLC system LHLC-B10

HPLC system LHLC-B10

High pressure pump : High pressure gradient pump

Peak operating pressure : 45 MPa, Stainless steel pump

Pressure : ± 0.02 MPa

HPLC system LHLC-A11
HPLC system LHLC-A11

High pressure pump : Two sets of pump

Flow rate range : 0.001 - 9.999 mL / min (0.001 mL / min increments)

Pressure range : ≤ 0.5 MPa (0 - 42 MPa)

Analytical HPLC

Analytical HPLC-A7835

Pump Specifications
Model No HPP-B1
Flow rate range 0.0001 to 10 ml / min
Maximum pressure 42 MPa , 0 to 5 ml / min
Column size 4.6 × 250 mm
Sample size 5 μm
Pressure pulsation ≤ 1.5 % at 10 MPa
Flow rate accuracy ± 0.2 % at 1 ml / min
Flow rate repeatability % ≤ 0.15
Gradient accuracy % ± 2
Gradient repeatability % ≤ 0.2
Dimension 450 × 260 × 190 mm
Power supply 90 V to 240 V
Weight 11.2 kg
Detector Specifications
Model No HPD-B2
Wavelength range 190 to 800 nm
Wavelength accuracy ± 0.75 nm
Wavelength repeatability 0.2 nm
Band width 8 nm
Optical path 10 nm
Deuterium lamp 190 to 400 nm
Tungsten lamp 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.5 × 10 -5
Baseline drift ( Static ) Au / h ≤ 1.5 x 10 -4
Minimum detection limit ≤ 4 x 10 -8
Power 100 W
Power supply 90 V / 50 to 60 Hz
Dimension 460 × 260 × 190 mm
Weight 9.2 kg

Analytical HPLC-A7832

Detector Specifications
Model No HPD-A20 HPD-A21
Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
Wavelength accuracy ± 0.5 nm ± 2 nm
Wavelength repeatability 0.15 nm 0.3 nm
Band width 8 nm 8 nm
Optical path 10 nm 10 nm
Deuterium lamp 190 to 400 nm 190 to 400 nm
Tungsten lamp 400 to 800 nm 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
Power 100 W 100 W
Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
Weight 9.5 kg 9.5 kg
Pump Specifications
Flow rate range 0.0001 to 10 ml / min
Maximum pressure 50 MPa , 0 to 2 ml / min
Column size 4.6 × 250 mm
Sample size 5 µm
Pressure pulsation ≤ 1 % at 10 MPa
Flow rate accuracy ± 0.15 % at 1 ml / min
Flow rate repeatability % ≤ 0.1
Gradient accuracy % ± 1.5
Gradient repeatability % ≤ 0.2
Dimension 460 × 310 × 180 mm
Power supply 90 V
Weight 11.6 kg

Talk to us?