HPLC system LHLC-B11

This HPLC system delivers high quality performance and reliable results in order to meet the stringent requirements of the customer. To meet GMP/GLP requirements of the instrument, this HPLC system has hardware with VP function which records maintenance information and operations.

Buy Now View Catalog
High pressure pump High pressure constant-current infusion pump
Infusion Way Micro volume series dual-piston
Infusion pressure 0 - 9999 Psi
Flow rate ≤ 0.5 %
Flow rate range 0.001 - 9.999 mL / min (in 0.001 mL / min increments)
Stability error for the flow rate ≤ 0.2 % RSD
Gradient error ± 1 % (0 - 100 % water/acetone solvent)
Pressure pulsation < 15 Psi (flow rate 1 mL / min, pressure 600 - 1600 Psi)
Air tightness Pressure 5400 Psi, 10 min time, pressure drop < 400 Psi
Time program function Yes
Size (W × H × D) 260 × 130 × 420 mm
Weight 11 kg
Operation temperature 4 - 40 ºC
UV detector
  • Wavelength range: 240
  • Wavelength error: ≤ 1 nm
  • Wavelength repeatability error: ≤ ± 0.1 nm
  • Dynamic noise: ≤ ± 0.75 × 10-5 AU (methyl alcohol 1 mL / min, 254 nm, 20 ºC)
  • Static noise: ≤ ± 0.5 × 10-5 A (empty cell, response time, 1 second, 20 ºC)
  • Dynamic baseline Drift: ≤ ± 1 × 10-4 AU / h (methyl alcohol 1 mL / min, 254 nm, 20 ºC)
  • Static baseline Drift: ≤ 0.5 × 10-4 (empty cell, response time, 1 second, 20 ºC)
  • Linear range: ≥ 104
  • Limit of detection: ≤ 1 × 10-9 g / ml (Naphthalene methyl alcohol solvent)
  • Quantitative repeatability: RSD 6 ≤ 0.1 %
  • Qualitative repeatability: RSD 6 ≤ 0.5 %
  • Spectrum band width: 6 nm
  • Flow cell volume: 8 µL
  • Optical path: 10 nm
  • Time program function: Yes
  • Size (W × H × D): 260 × 130 × 420 mm
  • Weight: 11 kg
  • Operation Temperature: 4 - 40 ºC
  • High pressure constant-current infusion pump
    Even mixing of the injections using mixers
    Supreme appearance to meet the customer’s visual requirements
    Simple, easy to use operations
    UV detector unit consists of dual beam monochromator, light battery, deuterium lamp

This HPLC has applications in the scientific research studies, detection of residual amount in medicine, food, alcohol and in chemical analysis.

{"High pressure pump":"High pressure constant-current infusion pump","Infusion Way":"Micro volume series dual-piston","Infusion pressure":"0 - 9999 Psi","Flow rate":"\u2264 0.5 %","Flow rate range":"0.001 - 9.999 mL \/ min (in 0.001 mL \/ min increments)","Stability error for the flow rate":"\u2264 0.2 % RSD","Gradient error":"\u00b1 1 % (0 - 100 % water\/acetone solvent)","Pressure pulsation":"< 15 Psi (flow rate 1 mL \/ min, pressure 600 - 1600 Psi)","Air tightness":"Pressure 5400 Psi, 10 min time, pressure drop < 400 Psi","Time program function":"Yes","Size (W \u00d7 H \u00d7 D)":"260 \u00d7 130 \u00d7 420 mm","Weight":"11 kg","Operation temperature":"4 - 40 \u00baC","UV detector":{"Wavelength range":"240","Wavelength error":"\u2264 1 nm","Wavelength repeatability error":"\u2264 \u00b1 0.1 nm","Dynamic noise":"\u2264 \u00b1 0.75 \u00d7 10-5<\/sup> AU (methyl alcohol 1 mL \/ min, 254 nm, 20 \u00baC)","Static noise":"\u2264 \u00b1 0.5 \u00d7 10-5<\/sup> A (empty cell, response time, 1 second, 20 \u00baC)","Dynamic baseline Drift":"\u2264 \u00b1 1 \u00d7 10-4<\/sup> AU \/ h (methyl alcohol 1 mL \/ min, 254 nm, 20 \u00baC)","Static baseline Drift":"\u2264 0.5 \u00d7 10-4<\/sup> (empty cell, response time, 1 second, 20 \u00baC)","Linear range":"\u2265 104","Limit of detection":"\u2264 1 \u00d7 10-9<\/sup> g \/ ml (Naphthalene methyl alcohol solvent)","Quantitative repeatability":"RSD 6 \u2264 0.1 %","Qualitative repeatability":"RSD 6 \u2264 0.5 %","Spectrum band width":"6 nm","Flow cell volume":"8 \u00b5L","Optical path":"10 nm","Time program function":"Yes","Size (W \u00d7 H \u00d7 D)":"260 \u00d7 130 \u00d7 420 mm","Weight":"11 kg","Operation Temperature":"4 - 40 \u00baC"}}
High pressure constant-current infusion pump
Even mixing of the injections using mixers
Supreme appearance to meet the customer’s visual requirements
Simple, easy to use operations
UV detector unit consists of dual beam monochromator, light battery, deuterium lamp
This HPLC has applications in the scientific research studies, detection of residual amount in medicine, food, alcohol and in chemical analysis.


Related Products of Standard HPLC

HPLC system LHLC-A10

HPLC system LHLC-A10

High pressure pump : Single pump

Flow rate range : 0.001 - 9.999 mL / min (0.001 mL / min increment)

Pressure range : ≤ 0.5 MPa (0 - 42 MPa)

HPLC system LHLC-B10

HPLC system LHLC-B10

High pressure pump : High pressure gradient pump

Peak operating pressure : 45 MPa, Stainless steel pump

Pressure : ± 0.02 MPa

HPLC system LHLC-A11
HPLC system LHLC-A11

High pressure pump : Two sets of pump

Flow rate range : 0.001 - 9.999 mL / min (0.001 mL / min increments)

Pressure range : ≤ 0.5 MPa (0 - 42 MPa)

Analytical HPLC

Analytical HPLC-A7835

Pump Specifications
Model No HPP-B1
Flow rate range 0.0001 to 10 ml / min
Maximum pressure 42 MPa , 0 to 5 ml / min
Column size 4.6 × 250 mm
Sample size 5 μm
Pressure pulsation ≤ 1.5 % at 10 MPa
Flow rate accuracy ± 0.2 % at 1 ml / min
Flow rate repeatability % ≤ 0.15
Gradient accuracy % ± 2
Gradient repeatability % ≤ 0.2
Dimension 450 × 260 × 190 mm
Power supply 90 V to 240 V
Weight 11.2 kg
Detector Specifications
Model No HPD-B2
Wavelength range 190 to 800 nm
Wavelength accuracy ± 0.75 nm
Wavelength repeatability 0.2 nm
Band width 8 nm
Optical path 10 nm
Deuterium lamp 190 to 400 nm
Tungsten lamp 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.5 × 10 -5
Baseline drift ( Static ) Au / h ≤ 1.5 x 10 -4
Minimum detection limit ≤ 4 x 10 -8
Power 100 W
Power supply 90 V / 50 to 60 Hz
Dimension 460 × 260 × 190 mm
Weight 9.2 kg

Analytical HPLC-A7832

Detector Specifications
Model No HPD-A20 HPD-A21
Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm )
Wavelength accuracy ± 0.5 nm ± 2 nm
Wavelength repeatability 0.15 nm 0.3 nm
Band width 8 nm 8 nm
Optical path 10 nm 10 nm
Deuterium lamp 190 to 400 nm 190 to 400 nm
Tungsten lamp 400 to 800 nm 400 to 800 nm
Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5
Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4
Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8
Power 100 W 100 W
Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz
Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm
Weight 9.5 kg 9.5 kg
Pump Specifications
Flow rate range 0.0001 to 10 ml / min
Maximum pressure 50 MPa , 0 to 2 ml / min
Column size 4.6 × 250 mm
Sample size 5 µm
Pressure pulsation ≤ 1 % at 10 MPa
Flow rate accuracy ± 0.15 % at 1 ml / min
Flow rate repeatability % ≤ 0.1
Gradient accuracy % ± 1.5
Gradient repeatability % ≤ 0.2
Dimension 460 × 310 × 180 mm
Power supply 90 V
Weight 11.6 kg