Kinematics Viscometer LKV-A10 is designed with hard glass bath and electric stirring device with 1200 rpm stirring motor. Designed as per ASTM D445 standard configuration, features ambient to 100°C of temperature range and 0 to 9999.9 s of time range. Compact design with RTD PT100 sensor for uniform bath temperature and 6 capillary Pinkevitch viscometer tubes, it is an ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature.
Buy Now View Catalog| Ambient temperature | 15 to 35°C |
| Relative humidity | ≤ 85% |
| Capillary viscometer | 6 capillary Pinkevitch viscometer tubes |
| Stirring motor | 1200 rpm |
| Temperature range | Ambient to 100°C |
| Temperature accuracy | ±0.1℃ |
| Time range | 0 to 9999.9 s |
| Temperature sensor | RTD PT100 |
| Capillary viscometer diameter | 0.6 mm, 0.8 mm, 1mm, 1.2 mm, 1.5 mm, 2 mm |
| Bath capacity | 12 L |
| Bath size | Φ255×240 mm |
| Dimension (W×D×H) | 500×310×500 mm |
| Net weight | 11.5 kg |
Kinematics Viscometer is used to measure flow times for a fixed volume of fuel to flow under gravity through a capillary of the viscometer across the fields of petroleum and its products industries, research and development department etc.
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Ambient temperature : 0 ~ 40 ºC
Relative humidity : 20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy : ± 0.1 °C
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 13 pieces
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
| Graduated flask | 100 ml,50 ml |
| Conical flask | 100ml |
| Separatory funnel | 250ml |
| Ambient temperature | ≤ 35 °C |
| Relative humidity | ≤ 85 % |
| Precision of titration tube | Scale division is 0.02 ml |
| Measurement range | Room temperature ~ 150°C |
| Stirring speed | 0 ~ 1200 r / min |
| Heating power | 25 W |
| Temperature controlling accuracy | ≤ 0.5 ℃ |
| Temperature controlling range | Room temperature ~ 200 ℃ |
| Power supply for illumination | 5 V |
| Electric Muffle Furnace |
|
||||||||||||||||
| Temperature controller |
|
||||||||||||||||
| Electric heating plate |
|
| Capacity | 2.0 kVA |
| Speed of voltage increase | 2 k V/ s |
| Voltage inspection accuracy | 0.01 |
| Calorimeter type | Isoperibol |
| Temperature range | 5 to 40°C |
| Measurement range | 5 to 40 MJ/ kg |
| Calorimeter type | Isoperibol |
| Temperature range | 5 to 40°C |
| Measurement range | 5 to 40 MJ/ kg |