Kinematics Viscometer LKV-A10

Kinematics Viscometer LKV-A10 is designed with hard glass bath and electric stirring device with 1200 rpm stirring motor. Designed as per ASTM D445 standard configuration, features ambient to 100°C of temperature range and 0 to 9999.9 s of time range. Compact design with RTD PT100 sensor for uniform bath temperature and 6 capillary Pinkevitch viscometer tubes, it is an ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature.

Buy Now View Catalog
Ambient temperature 15 to 35°C
Relative humidity ≤ 85%
Capillary viscometer 6 capillary Pinkevitch viscometer tubes
Stirring motor 1200 rpm
Temperature range Ambient to 100°C
Temperature accuracy ±0.1℃
Time range 0 to 9999.9 s
Temperature sensor RTD PT100
Capillary viscometer diameter 0.6 mm, 0.8 mm, 1mm, 1.2 mm, 1.5 mm, 2 mm
Bath capacity 12 L
Bath size Φ255×240 mm
Dimension (W×D×H) 500×310×500 mm
Net weight 11.5 kg
  • Hard glass bath, allow personnel to observe liquid flow
    Electric stirring device with 1200 rpm stirring motor
    Ambient to 100°C of temperature range and 0 to 9999.9 s of time range
    RTD PT100 sensor for uniform bath temperature
    6 capillary Pinkevitch viscometer tubes with different inner diameters
    Designed as per ASTM D445 standard configuration
    An ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature

Kinematics Viscometer is used to measure flow times for a fixed volume of fuel to flow under gravity through a capillary of the viscometer across the fields of petroleum and its products industries, research and development department etc.

{"Ambient temperature":"15 to 35\u00b0C","Relative humidity":"\u2264 85%","Capillary viscometer":"6 capillary Pinkevitch viscometer tubes","Stirring motor":"1200 rpm","Temperature range":"Ambient to 100\u00b0C","Temperature accuracy":"\u00b10.1\u2103","Time range":"0 to 9999.9 s","Temperature sensor":"RTD PT100","Capillary viscometer diameter":"0.6 mm, 0.8 mm, 1mm, 1.2 mm, 1.5 mm, 2 mm","Bath capacity":"12 L","Bath size":"\u03a6255\u00d7240 mm","Dimension (W\u00d7D\u00d7H)":"500\u00d7310\u00d7500 mm","Net weight":"11.5 kg"}
Hard glass bath, allow personnel to observe liquid flow
Electric stirring device with 1200 rpm stirring motor
Ambient to 100°C of temperature range and 0 to 9999.9 s of time range
RTD PT100 sensor for uniform bath temperature
6 capillary Pinkevitch viscometer tubes with different inner diameters
Designed as per ASTM D445 standard configuration
An ideal unit to determine kinematic viscosity of liquid petroleum products (Newtonian fluids) at a constant temperature
Kinematics Viscometer is used to measure flow times for a fixed volume of fuel to flow under gravity through a capillary of the viscometer across the fields of petroleum and its products industries, research and development department etc.


Related Products of Kinematics Viscometer

Kinematics Viscometer LKV-A15

Kinematics Viscometer LKV-A15

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 11 pieces

Kinematics Viscometer LKV-A12

Kinematics Viscometer LKV-A12

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 11 pieces

Kinematics Viscometer LKV-A16
Kinematics Viscometer LKV-A16

Ambient temperature : 0 ~ 40 ºC

Relative humidity : 20 ~ 90 %, RH while 40 ℃

Temperature controlling accuracy : ± 0.1 °C

Kinematics Viscometer LKV-A11
Kinematics Viscometer LKV-A11

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 11 pieces

Kinematics Viscometer LKV-A13

Kinematics Viscometer LKV-A13

Ambient temperature : (-10) °C ~ 35 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group

Low Temperature Kinematic Viscosity Tester LKV-A14

Low Temperature Kinematic Viscosity Tester LKV-A14

Ambient temperature : ≤ 30 °C

Relative humidity : ≤ 85 %

Capillary viscometer : 13 pieces

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W

Aniline Point Tester LAPT-A11

Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Ash Content Tester

Ash Content Tester LACT-A10
Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Talk to us?