Our LKV-A13 is a double layered, desktop structured Kinematic Viscometer which is designed as per ASTM D2171 / D2171M - 10 “Asphalt Kinematic Viscosity Test (Capillary Viscometer Methods”.
Buy Now View CatalogAmbient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | 3 piece at the same time |
Bath temperature | Ambient temperature ~ 180.0 °C |
Measurement range | 100 ~ 150 °C or 150 ~ 200 °C |
Bath cubage | 23 L |
Temperature controlling range | |
Temperature controlling accuracy | ± 0.1 °C |
Illumination | |
Constant temperature bath | |
Timing range | |
Barometric | |
Timing accuracy | |
Timing device | |
Temperature sensor | |
Inner capillary viscometer diameters | 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm |
Mercury thermometer scale division | 0.1 °C |
It is used in the fields of petroleum & its products industries, research and development department.
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 13 pieces
Ambient temperature : 0 ~ 40 ºC
Relative humidity : 20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy : ± 0.1 °C
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Ambient temperature : 15 to 35°C
Relative humidity : ≤ 85%
Capillary viscometer : 6 capillary Pinkevitch viscometer tubes
Capacity | 2.0 kVA |
Speed of voltage increase | 2 k V/ s |
Voltage inspection accuracy | 0.01 |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |
Electric Muffle Furnace |
|
||||||||||||||||
Temperature controller |
|
||||||||||||||||
Electric heating plate |
|
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Talk to us?