Labtron LKV-A15 is fully automated kinematic viscometer, designed with single chip microcomputer and Industrial Platinum Temperature Sensor. It is accorded as per ASTM D445 “Test Methods for Kinematic Viscosity of Petroleum Products and Calculation of Dynamic Viscosity”.
Buy Now View CatalogAmbient temperature | (-10) °C ~ 35 °C |
Relative humidity | ≤ 85 % |
Capillary viscometer | 11 pieces |
Stirring motor | 6 W, 1200 rpm |
Sample quantity | 4 piece at the same time |
Bath temperature | |
Measurement range | Ambient Temperature ~ 100.0 °C |
Bath cubage | 20 L |
Temperature controlling range | |
Temperature controlling accuracy | ± 0.1 °C |
Illumination | |
Constant temperature bath | |
Timing range | 0.0 s ~ 9999.9 s |
Barometric | |
Timing accuracy | ≤ ± 0.05 % in 60 min |
Timing device | |
Temperature sensor | |
Inner capillary viscometer diameters | 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 2.5, 3.0, 3.5, and 4.0 mm |
Mercury thermometer scale division |
It is used in the fields of petroleum & its products industries, research and development department.
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 13 pieces
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Ambient temperature : 15 to 35°C
Relative humidity : ≤ 85%
Capillary viscometer : 6 capillary Pinkevitch viscometer tubes
Ambient temperature : 0 ~ 40 ºC
Relative humidity : 20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy : ± 0.1 °C
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Calorimeter type | Isoperibol |
Temperature range | 5 to 40°C |
Measurement range | 5 to 40 MJ/ kg |
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Precision of titration tube | Scale division is 0.02 ml |
Graduated flask | 100 ml,50 ml |
Conical flask | 100ml |
Separatory funnel | 250ml |
Electric Muffle Furnace |
|
||||||||||||||||
Temperature controller |
|
||||||||||||||||
Electric heating plate |
|
Capacity | 2.0 kVA |
Speed of voltage increase | 2 k V/ s |
Voltage inspection accuracy | 0.01 |
Temperature controlling accuracy | ≤ 0.5 ℃ |
Temperature controlling range | Room temperature ~ 200 ℃ |
Power supply for illumination | 5 V |
Measurement range | Room temperature ~ 150°C |
Stirring speed | 0 ~ 1200 r / min |
Heating power | 25 W |