Penetrometer LMPT-A13

Penetrometer LMPT-A13 is a fully automatic unit for determining needle penetration of highway bitumen, modified asphalt, as well as liquid petroleum asphalt or residue of emulsified asphalt after evaporation material. It has 0.6 penetration measurement accuracy with stable test repeatability. Automatic drawing and print of nomogram of asphalt penetration with special designed computer drawing software and data accurate reading technology. Consists of automatic lifting device for penetration measurement. It is ideally used for petroleum, emulsified asphalt and highway bitumen, etc.

Buy Now View Catalog
Measurement range 0 to 600 penetration scale
Timing range 0 sec to 60 sec
Time accuracy error ≥ ± 0.1 seconds
Resolution 0.1 penetration
Power consumption 200 W
Power supply AC 220 V ± 10 %, 50 Hz
Needle diameter 50 mm
Sample container (D × H) 55 mm × 35 mm
Dimensions (L × W × H) 260 × 400 × 600 mm
Standard weight 50 g
Weight of standard needle 2.5 ± 0.05 g
Net Weight 15 kg
  • Measurement accuracy reaches up to 0.6 penetrations
    Equipped with high resolution capacitance touch screen
    Installed specific computer drawing software and data accurate reading technology
    Automatic draw and printing of nomogram of asphalt penetration
    Equipped with automatic lifting device
    Stable test repeatability with new detection unit

Widely used for determining needle penetration of highway bitumen, modified asphalt, as well as liquid petroleum asphalt or residue of emulsified asphalt after evaporation.

{"Measurement range":"0 to 600 penetration scale","Timing range":"0 sec to 60 sec","Time accuracy error":"\u2265 \u00b1 0.1 seconds","Resolution":"0.1 penetration","Power consumption":"200 W","Power supply":"AC 220 V \u00b1 10 %, 50 Hz","Needle diameter":"50 mm","Sample container (D \u00d7 H)":"55 mm \u00d7 35 mm","Dimensions (L \u00d7 W \u00d7 H)":"260 \u00d7 400 \u00d7 600 mm","Standard weight":"50 g","Weight of standard needle":"2.5 \u00b1 0.05 g","Net Weight":"15 kg"}
Measurement accuracy reaches up to 0.6 penetrations
Equipped with high resolution capacitance touch screen
Installed specific computer drawing software and data accurate reading technology
Automatic draw and printing of nomogram of asphalt penetration
Equipped with automatic lifting device
Stable test repeatability with new detection unit
Widely used for determining needle penetration of highway bitumen, modified asphalt, as well as liquid petroleum asphalt or residue of emulsified asphalt after evaporation.


Related Products of Penetrometer

Penetrometer LMPT-A12

Penetrometer LMPT-A12

Penetrometer :

  • Measurement range: 0 to 600 penetration scale
  • Timing controller: 5 sec or 60 sec
  • Time accuracy: ± 0.1 seconds
  • Resolution: 0.1 penetration
  • Penetration accuracy: ± 1 penetration
  • Weight of standard needle: 2.5 ± 0.05 g
  • Dimensions (W × L × H): 700 × 400 × 750 mm
  • Weight: 30 kg

Circulatory Water Bath :

  • Bath volume: 3.5 L
  • Temperature range: 5 °C to 60 °C
  • Temperature accuracy: ± 0.1 °C
  • Circulatory water quantity: 3 L/minute
  • Pump Lift: 2 m
  • Power consumption: 1200 W
  • Power supply: AC 220V ± 10 %, 50 Hz
  • Dimensions (W × L × H): 600 × 400 × 650 mm
  • Weight: 40 kg

Penetrometer LMPT-A11

Penetrometer LMPT-A11

Measurement range : 0 to 600 penetration scale

Timing controller : 5 sec or 60 sec

Time accuracy : ± 0.1 seconds

Penetrometer LMPT-A10
Penetrometer LMPT-A10

Measurement range : 0 to 600 penetration scale

Timing controller : 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec

Time accuracy : ± 0.1 seconds

Ash Content Tester

Ash Content Tester LACT-A10

Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A10

Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A11
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Aniline Test Equipment

Aniline Point Tester LAPT-A11
Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Aniline Point Tester LAPT-A10

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10

Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01

Acid and Alkali Tester

Water Soluble Acid and Alkali Tester LAAT-A10
Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml
Acid Number and Acidity Tester LAAT-A11
Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Talk to us?