Penetrometer LMPT-A12

Penetrometer LMPT-A12 is a two grade low temperature controlled unit for determining penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt with time control. It has digital display which shows penetration number of sample. Separate automatic low temperature circulatory water bath for maintaining constant temperature on the unit. It is ideally used for different types of asphalt, food industries, highway engineering, etc.

Buy Now View Catalog
Penetrometer
  • Measurement range: 0 to 600 penetration scale
  • Timing controller: 5 sec or 60 sec
  • Time accuracy: ± 0.1 seconds
  • Resolution: 0.1 penetration
  • Penetration accuracy: ± 1 penetration
  • Weight of standard needle: 2.5 ± 0.05 g
  • Dimensions (W × L × H): 700 × 400 × 750 mm
  • Weight: 30 kg
Circulatory Water Bath
  • Bath volume: 3.5 L
  • Temperature range: 5 °C to 60 °C
  • Temperature accuracy: ± 0.1 °C
  • Circulatory water quantity: 3 L/minute
  • Pump Lift: 2 m
  • Power consumption: 1200 W
  • Power supply: AC 220V ± 10 %, 50 Hz
  • Dimensions (W × L × H): 600 × 400 × 650 mm
  • Weight: 40 kg
  • Digital display shows penetration number of the sample
    Two grade of timing control
    Adjustable needle holder
    Designed for low temperature measurement
    Circulatory water bath maintains constant temperature
    Low temperature can be preset for different specimens

Widely used for determining needle penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt, also for solid particle, powder, colloid mixture, highway engineering and food materials such as glycine, cheese, butter, cream, leavening agents, etc.

{"Penetrometer":{"Measurement range":"0 to 600 penetration scale","Timing controller":"5 sec or 60 sec","Time accuracy":"\u00b1 0.1 seconds","Resolution":"0.1 penetration","Penetration accuracy":"\u00b1 1 penetration","Weight of standard needle":"2.5 \u00b1 0.05 g","Dimensions (W \u00d7 L \u00d7 H)":"700 \u00d7 400 \u00d7 750 mm","Weight":"30 kg"},"Circulatory Water Bath":{"Bath volume":"3.5 L","Temperature range":"5 \u00b0C to 60 \u00b0C","Temperature accuracy":"\u00b1 0.1 \u00b0C","Circulatory water quantity":"3 L\/minute","Pump Lift":"2 m","Power consumption":"1200 W","Power supply":"AC 220V \u00b1 10 %, 50 Hz","Dimensions (W \u00d7 L \u00d7 H)":"600 \u00d7 400 \u00d7 650 mm","Weight":"40 kg"}}
Digital display shows penetration number of the sample
Two grade of timing control
Adjustable needle holder
Designed for low temperature measurement
Circulatory water bath maintains constant temperature
Low temperature can be preset for different specimens
Widely used for determining needle penetration of pavement petroleum asphalt, modified asphalt, liquid petroleum asphalt and emulsified asphalt, also for solid particle, powder, colloid mixture, highway engineering and food materials such as glycine, cheese, butter, cream, leavening agents, etc.


Related Products of Penetrometer

Penetrometer LMPT-A13

Penetrometer LMPT-A13

Measurement range : 0 to 600 penetration scale

Timing range : 0 sec to 60 sec

Time accuracy error : ≥ ± 0.1 seconds

Penetrometer LMPT-A10

Penetrometer LMPT-A10

Measurement range : 0 to 600 penetration scale

Timing controller : 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec

Time accuracy : ± 0.1 seconds

Penetrometer LMPT-A11
Penetrometer LMPT-A11

Measurement range : 0 to 600 penetration scale

Timing controller : 5 sec or 60 sec

Time accuracy : ± 0.1 seconds

Acid and Alkali Tester

Acid Number and Acidity Tester LAAT-A11

Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Precision of titration tube Scale division is 0.02 ml

Water Soluble Acid and Alkali Tester LAAT-A10

Graduated flask 100 ml,50 ml
Conical flask 100ml
Separatory funnel 250ml

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10
Calorimeter type Isoperibol
Temperature range 5 to 40°C
Measurement range 5 to 40 MJ/ kg

Aniline Test Equipment

Aniline Point Tester LAPT-A11

Temperature controlling accuracy ≤ 0.5 ℃
Temperature controlling range Room temperature ~ 200 ℃
Power supply for illumination 5 V

Aniline Point Tester LAPT-A10

Measurement range Room temperature ~ 150°C
Stirring speed 0 ~ 1200 r / min
Heating power 25 W

Ash Content Tester

Ash Content Tester LACT-A10
Electric Muffle Furnace
Controlled temperature 775 ±25 ℃
Temperature rising time of empty chamber ≤ 50 min
Furnace temperature uniformity ≤ 15℃
Internal dimension 200 × 120 × 80 mm
External dimension 490 × 490 × 450 mm
Power consumption 2.5 kW
Power supply AC 220V ±10%, 50 Hz
Net weight 35 kg
Temperature controller
Maximum control temperature 1200 ℃
Dimension 500 × 300 × 235 mm
Power consumption 5000 W
Power supply AC 220±10% V, 50Hz
Net weight 5 kg
Electric heating plate
Heating power (1 to 6) grades, continuously adjustable
Temperature 400℃
Diameter of heating plate Φ 180 mm
Dimension 280 × 250 × 90 mm
Power consumption 2000 W
Power supply AC 220±10%V, 50Hz

Automatic Dielectric Tester

Automatic Dielectric Tester LADT-A10
Capacity 2.0 kVA
Speed of voltage increase 2 k V/ s
Voltage inspection accuracy 0.01