Bench top Turbidity Meter (with built-in printer) LTM-C12

Bench top turbidity meter (with built-in printer) LTM-C12 comes with microprocessor controlled system, works on 90° scattered light principle to measure water turbidity in nephelometric turbidity unit i.e. NTU. The formazine standard solution of turbidity mentioned in ISO 7027 is used for turbidity analysis. This turbidity meter delivers highly accurate results with better numerical calculations to meet GLP standards.

Buy Now View Catalog
Measuring range (NTU) 0 to 10, 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) 0.001
Calibration point 4
Sample volume 18 to 20 ml
Principle method 90° scattered light
Operating temperature Room Temperature
Working temperature Room Temperature
Light source Infrared-emitting diode (850 nm λ)
Detector Silicon photodiode
Error value (F.S) ±2%, ±3%,±5% 
Zero drift (F.S) ±0.5% (0.02 NTU)
Reset functions No
Memory Nil
Output RS232 data communication interface
Dimension 415 × 375 × 200 mm
Weight 4 kg
Power batteries DC 1.5 V, 5 AA alkaline batteries
Power supply AC 220 V, 50 Hz
  • Equipped with Built-in printer
    Touch keypad backlight LCD display
    Wide turbidity measurement range
    High through put stability
    Quick and automatic multi-points calibration
    Auto power off function
    Easy to operate
Accessory No. Name Quantity
1 Specimen bottle 3 pcs
2 400 NTU (Formazine) turbidity standard solution 1 bottle
3 Power cable 1 pc

Used in water treatment plants, swimming pool, water recycling units, research and quality testing laboratories of pharmacy, life science, food, and beverage industry.

{"Measuring range (NTU)":"0 to 10,\n0 to 100,\n0 to 200,\n0 to 500","Minimum readout value (NTU)":"0.001","Calibration point":"4","Sample volume":"18 to 20 ml","Principle method":"90\u00b0 scattered light","Operating temperature":"Room Temperature","Working temperature":"Room Temperature","Light source":"Infrared-emitting diode (850 nm \u03bb)","Detector":"Silicon photodiode","Error value":"(F.S)\u00a0\u00b12%,\u00a0\u00b13%,\u00b15%\u00a0","Zero drift":"(F.S)\u00a0\u00b10.5%\u00a0(0.02\u00a0NTU)","Reset functions":"No","Memory":"Nil","Output":"RS232 data communication interface","Dimension":"415 \u00d7 375 \u00d7 200 mm","Weight":"4 kg","Power batteries":"DC 1.5 V, 5 AA alkaline batteries","Power supply":"AC 220 V, 50 Hz"}
Equipped with Built-in printer
Touch keypad backlight LCD display
Wide turbidity measurement range
High through put stability
Quick and automatic multi-points calibration
Auto power off function
Easy to operate
Used in water treatment plants, swimming pool, water recycling units, research and quality testing laboratories of pharmacy, life science, food, and beverage industry.


Related Products of Turbidity Meter

Portable Turbidity Meter LTM-A15

Portable Turbidity Meter LTM-A15

Measuring range (NTU) : 0 to 100, 100 to 1000

Minimum readout value (NTU) : 0.01, 0.1

Calibration point : 7

Portable Turbidity Meter LTM-A12

Portable Turbidity Meter LTM-A12

Measuring range (NTU) : 0 to 100, 100 to 400

Minimum readout value (NTU) : 0.01, 0.1

Calibration point : 5

Portable Turbidity Meter LTM-A10
Portable Turbidity Meter LTM-A10

Measuring range (NTU) : 0 to 200

Minimum readout value (NTU) : 0.1

Calibration point : Nil

Bench top Turbidity Meter (with built-in printer) LTM-C14
Bench top Turbidity Meter (with built-in printer) LTM-C14

Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000

Minimum readout value (NTU) : 0.001

Calibration point : 5

Portable Turbidity Meter LTM-A13

Portable Turbidity Meter LTM-A13

Measuring range (NTU) : 0 to 100, 100 to 500

Minimum readout value (NTU) : 0.01, 0.1

Calibration point : 6

Bench top Turbidity Meter (with built-in printer) LTM-C11

Bench top Turbidity Meter (with built-in printer) LTM-C11

Measuring range (NTU) : 0 to 100, 0 to 200, 0 to 500

Minimum readout value (NTU) : 0.01

Calibration point : 3

Bench top Turbidity Meter LTM-B10
Bench top Turbidity Meter LTM-B10

Measuring range (NTU) : 0 to 100

Minimum readout value (NTU) : 0.01, 0.1

Calibration point : 1

Bench top Turbidity Meter LTM-B11
Bench top Turbidity Meter LTM-B11

Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200

Minimum readout value (NTU) : 0.01, 0.1

Calibration point : 3

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water hardness meter LBWM-A10

Water hardness range 0.05 mmol / L -0.2 mol / L
(CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L
(German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy ± 1 % F.S.
Calibration points 2 to 5 points

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop conductivity meter LBCM-A11

Conductivity measurement range 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy ± 1 % F.S.
Conductivity resolution 0.01, 0.1, 1
Benchtop Conductivity Meter LBCM-A13
Conductivity measurement range 0.000 μS/cm to 3000mS/cm
Resistivity measurement range 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range 0.000 mg/L to 1000g/L

Benchtop Multi-parameter Water Quality Meter

Benchtop Multi-parameter Water Quality Meter LMPWM-A31
pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Multi-parameter Water Quality Meter LMPWM-A30

pH Mode
pH range -2.00 to 20.00 pH
pH Accuracy ± 0.002 pH
pH Resolution 0.1/0.01/0.001 pH, selectable
pH Calibration Points 1 to 5 Points
pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode
mV Range -1999.9 to 1999.9 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1/1 mV, selectable
mV Calibration Points 1 Point
Conductivity Mode
Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm
Conductivity Accuracy ± 0.5% F.S.
Conductivity Resolution 0.01/0.1/1
Conductivity Calibration Points 1 to 5 Points
Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm
Conductivity Temperature coefficient 0.0 to 10.0 %/°C
Compensation mode Linear or Pure Water
Cell Constant K=0.1, 1, 10 or Custom
Reference temperature 20 or 25°C

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved oxygen meter LBDO-A10

Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.5 mg / L
Resolution 0.1 mg / L
Benchtop Dissolved oxygen meter LBDO-A11
Dissolved oxygen range 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy ± 0.2 mg / L
Resolution 0.01 mg / L

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion meter for F, LBIM-A11
Ion measurement range F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Benchtop Ion meter for Cl, LBIM-A10

Ion measurement range Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1

Talk to us?