Beam Configuration |
Dual Channel |
Elements ( Measuring Range ) |
- As, Se, Pb, Bi, Sb, Te, Sn: < 0.01 µg/L
- Hg, Cd: < 0.001 µg/L
- Zn: < 1.0 µg/L
- Ge: < 0.1 µg/L
|
Precision ( RSD ) |
< 1.0 |
Linear range |
More than 3 orders of magnitude |
Lamp |
Hollow cathode lamp |
Power Supply |
220 V |
Dimension |
1000 x 350 x 390 mm |
Weight |
70 Kg |
-
Double channel detection for trace element analysis
Peak height and peak area integral detection method
High stability light source
High intensity hollow cathode lamps for high sensitivity and stability
Gas - liquid separator for improved repeatability of results
Double shielded quartz atomizer with automatic igniting argon – hydrogen flame
Stable gas flow
Automatic gas alarm pressure at critical point
USB communication for real time automatic detection
Used in analysis / detection of compound present in air of water, heavy metal detection, redirect photons , in various fields of geology, metallurgy, medicine, chemical industry, food inspection, water supply, waste water treatment and scientific research.
{"Beam Configuration":"Dual Channel","Elements ( Measuring Range )":{"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"},"Precision ( RSD )":"< 1.0","Linear range":"More than 3 orders of magnitude","Lamp":"Hollow cathode lamp","Power Supply":"220 V","Dimension":"1000 x 350 x 390 mm","Weight":"70 Kg"}
Double channel detection for trace element analysis
Peak height and peak area integral detection method
High stability light source
High intensity hollow cathode lamps for high sensitivity and stability
Gas - liquid separator for improved repeatability of results
Double shielded quartz atomizer with automatic igniting argon – hydrogen flame
Stable gas flow
Automatic gas alarm pressure at critical point
USB communication for real time automatic detection
Used in analysis / detection of compound present in air of water, heavy metal detection, redirect photons , in various fields of geology, metallurgy, medicine, chemical industry, food inspection, water supply, waste water treatment and scientific research.
Auto injector AU-A10 is used with atomic fluorescence spectrometer for steady, quick and accurate auto injection. It has a configuration of around 120-position injectors with a volume of 10 ml.
Features :
- Auto zero reset for the robotic arm
- 3D robotic arm with 3D locating deviations within a range of 0.1 mm
- Auto- identification of auto injector when software is turned on
- 120-injector disc with 10 ml of standard tube ( array of 15 x 8 )
- Zero reset cleaning position with minimum degree location of accumulation error
- Short auto-injector location time ( X and Y axis move at the same time )
- No injection drip
- Stable, fast and accurate low noise operation
- UV on-line digestion device upgradation available