Atomic Fluorescence Spectrometer LAFS-A10

Atomic Fluorescence Spectrometer LAFS-A10 is a microprocessor controlled double-channel, non-dispersive unit used for trace element composition, ultra-trace analysis of Mercury and all other hydride-forming elements. Pre adjusted referral optical plane to coincide atomizer center with optical focus. Equipped with a feature of real time conversion of data into graph.

Buy Now View Catalog
Beam Configuration Dual Channel
Elements ( Measuring Range )
  • As, Se, Pb, Bi, Sb, Te, Sn: < 0.01 µg/L
  • Hg, Cd: < 0.001 µg/L
  • Zn: < 1.0 µg/L
  • Ge: < 0.1 µg/L
Precision ( RSD ) < 1.0
Linear range More than 3 orders of magnitude
Lamp Hollow cathode lamp
Power Supply 220 V
Dimension 1000 x 350 x 390 mm
Weight 70 Kg
  • Double channel detection for trace element analysis
    Peak height and peak area integral detection method
    High stability light source
    High intensity hollow cathode lamps for high sensitivity and stability
    Gas - liquid separator for improved repeatability of results
    Double shielded quartz atomizer with automatic igniting argon – hydrogen flame
    Stable gas flow
    Automatic gas alarm pressure at critical point
    USB communication for real time automatic detection

Used in analysis / detection of compound present in air of water, heavy metal detection, redirect photons , in various fields of geology, metallurgy, medicine, chemical industry, food inspection, water supply, waste water treatment and scientific research.

{"Beam Configuration":"Dual Channel","Elements ( Measuring Range )":{"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"},"Precision ( RSD )":"< 1.0","Linear range":"More than 3 orders of magnitude","Lamp":"Hollow cathode lamp","Power Supply":"220 V","Dimension":"1000 x 350 x 390 mm","Weight":"70 Kg"}
Double channel detection for trace element analysis
Peak height and peak area integral detection method
High stability light source
High intensity hollow cathode lamps for high sensitivity and stability
Gas - liquid separator for improved repeatability of results
Double shielded quartz atomizer with automatic igniting argon – hydrogen flame
Stable gas flow
Automatic gas alarm pressure at critical point
USB communication for real time automatic detection
Used in analysis / detection of compound present in air of water, heavy metal detection, redirect photons , in various fields of geology, metallurgy, medicine, chemical industry, food inspection, water supply, waste water treatment and scientific research.

Auto injector AU-A10 is used with atomic fluorescence spectrometer for steady, quick and accurate auto injection. It has a configuration of around 120-position injectors with a volume of 10 ml.

Features :
  • Auto zero reset for the robotic arm
  • 3D robotic arm with 3D locating deviations within a range of 0.1 mm
  • Auto- identification of auto injector when software is turned on
  • 120-injector disc with 10 ml of standard tube ( array of 15 x 8 )
  • Zero reset cleaning position with minimum degree location of accumulation error
  • Short auto-injector location time ( X and Y axis move at the same time )
  • No injection drip
  • Stable, fast and accurate low noise operation
  • UV on-line digestion device upgradation available


Angular Spectrometer

Angular Spectrometer LASM-A10

Angle Measurement Accuracy 1inch
Optical Parameter
Focal Length 170 mm
Effective Aperture Φ 22 mm
Field of View 3° 22inch
Focal Length of Telescope’s Eyepiece 24.3 mm
Maximum Length Between Collimator and Telescope 120 mm
Slit Width 0.02 to 2 mm
Diopter Compensation Range ≥ ± 5 diopters
Divided Circle
Diameter Φ178 mm
Circle Graduation 0° to 360°
Division 0.5°
Vernier Reading Value 1inch

ICP Spectrometer

ICP Spectrometer LICP-B10

Monochromator Specifications
Optical type Czerny turner
Resolution ≤ 0.015nm (3600 line grating)
≤ 0.030nm (2400 line grating)
Focal length 1000 mm
Grating specifications huge holographic grating with 3600 L/mil or 2400 L/mil and 80 mm × 100 mm of ruling area
Wavelength range 195 to 500 nm for 3600 line grating
195 to 800 nm for 2400 line grating
Solid State Power Specifications
Frequency 27.12 MHz
Frequency stability: < 0.05%
Spray chamber Scott double pass spray chamber
Output power 800 W to 1600 W, adjustable with power efficiency more than 65%
Output power stability ≤ 0.05%
Induction coil 25 mm × 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)
Technical Specifications
Suitable sample content range Liquid sample: 0.01 ppm to several thousand ppm
Solid or power sample: 0.001% to 70%
Repeatability short-term stability- RSD ≤ 1.5%
Long-term stability: RSD ≤ 2%
Test speed 5 to 8 elements / min
Limits of detection (LOD, µg/L) for most elements 1ppb to 10ppb
ICP spectrometer LICP-A10
Wavelength range ( 3600 lines / mm ) 180 to 500 nm
Wavelength range ( 2400 lines / mm ) 180 to 800 nm
Temperature 20 ~ 28 °C

XRF Spectrometer

Handheld XRF Spectrometer LXRF-B10
Analytical Method Energy dispersive X-ray fluorescence analytical Method
Elements Measuring Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
Range Simultaneous detector

XRF-Spectrometer LXRF-A10

Measureable elements S to U
Detection limit 1 ppm
Temperature 15 ~ 30 °C

XRD Diffractometer

XRD Diffractometer LXRD-A10

X-ray Tuble Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
Focus Size 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
Stability ≤ 0.01 %

FTIR Spectrometer

FTIR Spectrometer LIR-B10
Spectral Range 7800 cm-1 to 350 cm-1
Resolution 0.85 cm-1
Wave number precision ± 0.01 cm-1

Talk to us?